GA 793.1-2008 English PDFUS$419.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GA 793.1-2008: Conformity assessment of city area monitoring and alarming network system--Part 1: Testing and verifying specifications for the functions and performance of system
Basic dataStandard ID: GA 793.1-2008 (GA793.1-2008)Description (Translated English): Conformity assessment of city area monitoring and alarming network system--Part 1: Testing and verifying specifications for the functions and performance of system Sector / Industry: Public Security (Police) Industry Standard Classification of Chinese Standard: A91 Classification of International Standard: 13.310 Word Count Estimation: 12,16 Date of Issue: 2008-08-04 Date of Implementation: 2008-08-04 Quoted Standard: GB 16796-1997; GB/T 17626.2-2006; GB/T 17626.4-1998; GB 20815-2006; GB 50198-1994; GB 50348-2004; GA/T 669.1-2008; GA/T 669.2-2008; GA/T 669.6-2008; GA/T 669.8-2008; GA/T 669.9-2008; GA/T 669.10-2008; GA/T 670-2006; GA 793.2-2008 Regulation (derived from): Industry Standard Record Announcement No. 4 of 2012 (No. 148) Issuing agency(ies): Ministry of Public Security Summary: This standard specifies the basic specifications of system functions and performance tests for conformity assessment of urban monitoring and alarming network system (hereinafter referred to as networked system), including general provisions, inspection procedures, inspection items, inspection requirements and inspection methods. This standard applies to the construction of urban monitoring alarm network system in the new, alteration, expansion of the system test. GA 793.1-2008: Conformity assessment of city area monitoring and alarming network system--Part 1: Testing and verifying specifications for the functions and performance of system---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Conformity assessment of city area monitoring and alarming network system - Part 1. Testing and verifying specifications for the functions and performance of system ICS 13.310 A91 People's Republic of China Public Security Industry Standards Urban network alarm monitoring system conformity assessment Part 1. System performance test function specification Posted 2008-08-04 2008-08-04 implementation People's Republic of China Ministry of Public Security Table of ContentsIntroduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 1 General Provisions 5 2 testing procedures 2 5.1 Test Registration 5.2 Test preparation 2 5.3 Test Example 2 5.4 Test Results and Treatment 2 6 networking system functionality, performance test 2 6.1 Networking System Networking before examination 3 6.2 Networking System function test 3 6.3 networking system performance test 5 7 7 networking systems security test 8 EMC networked system equipment, environmental adaptability test 8 9 9 Networking System Reliability Testing 10 network system construction quality, quality inspection equipment installation 9ForewordPlease note that the basic content of this section may involve patents, this part of the release mechanism should not bear the responsibility to identify these patents. Provisions of this Part 6,7,10 chapter with "" for mandatory provisions, other provisions are recommendatory. GA 793 "urban network alarm monitoring system conformity assessment" is divided into three parts. --- Part 1. System function test performance specifications; --- Part 2. Test Specification management software platform; --- Part 3. System acceptance. This section is part of the 1 GA 793. This part is proposed by the Ministry of Public Security Technology Bureau. This part of the National Security Alarm System Standardization Technical Committee (SAC/TC100) centralized. This section drafted by. National Security Alarm System Product Quality Supervision and Inspection Center (Beijing), Ministry of Public Security First Research Institute, Beijing Univision Aegis security technology company, the Guangdong Provincial Public Security Department of Science and Technology. The main drafters of this section. Li Xiulin, Shiju Ling, Yang Guosheng, Michael group. Urban network alarm monitoring system conformity assessment Part 1. System performance test function specification1 ScopeThe provisions of section GA 793 urban network alarm monitoring system (hereinafter referred to as networked systems) conformity assessment system functionality, performance The basic specification of the test, including general provisions, test procedures, test items, test requirements and test methods. This section applies to urban network alarm monitoring system construction in new construction, renovation, expansion of the system of inspection.2 Normative referencesThe following documents contain provisions which, through reference in this GA 793 constitute provisions of this part. For dated references, All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encourage the agreement on this section Are all aspects of the research to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. Alarm equipment safety requirements and test methods GB 16796-1997 security GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test (IEC 61000-4-2.2001, IDT) GB/T 17626.4-1998 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity test (idt IEC 61000- 4-4.1995) GB 20815-2006 video monitoring digital video equipment GB 50198-1994 civil closed circuit monitoring TV system engineering GB 50348-2004 security engineering and technical norms GA/T 669.1-2008 urban network alarm monitoring system technical requirements - Part 1. General technical requirements GA/T 669.2-2008 urban network alarm monitoring system technical requirements - Part 2. Safety requirements GA/T 669.6-2008 urban network alarm monitoring system technical requirements - Part 6. Depending on the audio display, storage and playback technology Claim GA/T 669.8-2008 urban network alarm monitoring system technical requirements - Part 8. transmission platform technology requirements GA/T 669.9-2008 urban network alarm monitoring system of technical standards Part 9. bayonet information recognition, matching, monitoring system EC technical requirements GA/T 669.10-2008 city Part 10 technical standards for network alarm monitoring system. wireless audio and video surveillance system technology Claim GA/T 670-2006 security systems, lightning surge protection Technical Requirements GA 793.2-2008 urban network alarm monitoring system of conformity assessment - Part 2. Test Specification Management Platform software3 Terms and DefinitionsGB 50348-2004, terms and definitions GA/T 669.1-2008 established in this section apply.4 General Provisions4.1 Networking System test shall be authorized by national or industry (approved) the inspection organizations. 4.2 networking system before testing, the system should try to run at least a month. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GA 793.1-2008_English be delivered?Answer: Upon your order, we will start to translate GA 793.1-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GA 793.1-2008_English with my colleagues?Answer: Yes. The purchased PDF of GA 793.1-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |