GA 703-2007 English PDF
Basic dataStandard ID: GA 703-2007 (GA703-2007)Description (Translated English): Fire safety requirement for the place combined with habitation, production, storage and busioness Sector / Industry: Public Security (Police) Industry Standard Classification of Chinese Standard: C80 Classification of International Standard: 13.220.20 Word Count Estimation: 7,734 Date of Issue: 2007-06-13 Date of Implementation: 2007-08-01 Quoted Standard: GB 20517; GB 50016; GB 50084; GB 50116; GB 50140; GB 50222; GB 50354 Issuing agency(ies): Ministry of Public Security Summary: This standard specifies the conditions for the combination of accommodation, production, storage and operation (commonly known as "triple play", hereinafter referred to as the "joint site"), and provides for fire separation measures, evacuation measures, fire fighting facilities, And other fire safety technical requirements. This standard applies to residential and production storage and operation of the place of fire safety management. GA 703-2007: Fire safety requirement for the place combined with habitation, production, storage and busioness---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Fire safety requirement for the place combined with habitation, production, storage and busioness ICS 13.220.20 C80 People's Republic of China Public Security Industry Standards Accommodation and combined production and storage business premises Fire Safety Requirements Posted 2007-06-13 2007-08-01 implementation People's Republic of China Ministry of Public Security Table of ContentsPreface Ⅰ Introduction Ⅱ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 basic provisions 1 5 fire separation measures 2 6 Auxiliary evacuation facilities 2 7 automatic fire extinguishing and fire alarm 2 8 fire source control 2 Other requirements 9 3Foreword4.1,4.2,4.3 this standard are mandatory, the rest are recommended. This standard was proposed by the Ministry of Public Security Fire Department. This standard by the National Standardization Technical Committee of the Ninth Fire Technical Committee (SAC/TC113/SC9) centralized. This standard was drafted. Ministry of Public Security Fire Bureau, the Shanghai Public Security Fire Department, Zhejiang Province Public Security Fire Department, Jiangsu Province Public Security Fire Total Team, Ministry of Public Security in Tianjin Fire Research Institute. The main drafters of this standard. Guotie Nan, Zhu Liping, MA Heng, she thinks, Shen Wen, Ji Chun Yin, Chen Youdi, Zhaoqing Ping, Feng Wang Bi, Xiong Jun, Zhu Ming, Yu Feng Jing, Song Shuxin, Tian Liang, Ni Zhaopeng, Zong deposit. This standard is the first release.IntroductionProvided at both plants, warehouses, shopping malls in the staff quarters, or engaged in the production, storage, management and other activities in residential and other civil construction, and Failing to stay part and take the necessary fire separation and fire-fighting facilities and other parts, so that this type of building fire safety requirements Incompatible with the nature of the use of the building, has a high fire risk. In order to implement the national fire prevention guidelines and policies to prevent and reduce fire Disaster, to protect personal safety, provide the basis for management of fire hazards, the development of this standard. Accommodation and combined production and storage business premises Fire Safety Requirements1 ScopeThis standard accommodation combined with production and storage business premises (commonly known as "triple play", hereinafter referred to as "combined premises") qualification, and Provisions of the combined properties of fire separation measures, evacuation facilities, fire facilities, as well as the source of fire control, fire safety technical requirements. This standard applies to both the production and storage of accommodation and management of fire safety in combination treatment sites.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 20517 independent smoke detection alarm GB 50016 architectural design code for fire protection GB 50084 sprinkler system design specifications GB 50116 automatic fire alarm system design specifications GB 50140 Building fire extinguishers configuration design specifications GB 50222 interior decoration of buildings for fire protection design GB 50354 interior decoration of buildings for fire prevention installation and acceptance3 Terms and DefinitionsThe following terms and definitions apply to this standard. 3.1 Accommodation and production, storage management and other mixed use one or several properties disposed within the same communication space.4 basic provisions4.1 combined properties should not be set within the following construction. a) There are A and B fire hazard production and storage management architecture; b) fire resistance rating of the building for the three and three below the building; c) plant and warehouse; d) building area of more than 2500m2 market shopping malls and other public buildings; e) underground construction. 4.2 combined with one of the following circumstances should not place window and door openings firewall and fire resistance of not less than 1.5h floor will Accommodation portion and non-residential part is completely separated, accommodation and non-residential portion should be set independent of the evacuation facilities; when it is difficult entirely separate, Staff accommodation should not be set. a) combination of place building height greater than 15m; Construction area b) is greater than the combined properties of 2000m2; ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GA 703-2007_English be delivered?Answer: Upon your order, we will start to translate GA 703-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GA 703-2007_English with my colleagues?Answer: Yes. The purchased PDF of GA 703-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |