GA 535-2005 English PDFUS$279.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GA 535-2005: Flame retarded and fire resistive cables -- Classification and specification of flame retarded rubber insulated cables Status: Obsolete
Basic dataStandard ID: GA 535-2005 (GA535-2005)Description (Translated English): Flame retarded and fire resistive cables -- Classification and specification of flame retarded rubber insulated cables Sector / Industry: Public Security (Police) Industry Standard Classification of Chinese Standard: C84 Classification of International Standard: 13.220.20 Word Count Estimation: 7,798 Date of Issue: 2005-03-17 Date of Implementation: 2005-10-01 Quoted Standard: GB/T 2951.1-1997; GB 5013; GB/T 18380.3; JB 8735 Summary: This standard specifies the definition, technical requirements, test methods, inspection rules, marking and packaging of flame-retardant rubber insulated cables. This standard applies to the rated voltage of 450 / 750V and flame retardant rubber insulated cables. GA 535-2005: Flame retarded and fire resistive cables -- Classification and specification of flame retarded rubber insulated cables---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Flame retarded and fire resistive cables -- Classification and specification of flame retarded rubber insulated cables ICS 13.220.20 C84 People's Republic of China Public Safety Industry Standard Flame retardant and fire resistant cable Flame retardant rubber insulated cable grading and requirements Released on.2005-03-17 Implemented.2005-10-01 Ministry of Public Security ForewordChapter 5 of this standard is mandatory and the rest are recommended. The products covered by this standard are products that guarantee the safety of personal and property. The technical indicators and test methods of mechanical and physical properties and electrical properties of flame-retardant rubber insulated cables specified in this standard are mainly based on GB 5013 "Rubber insulated cable with rated voltage of 450/750V and below", JB8735" Rubber insulated with rated voltage of 450/750V and below Wires and Flexible Cables and GB/T 2951 "General Test Methods for Cable Insulation and Sheath Materials"; Flame Retardancy Basis for Flame Retardant Cables GB/T 18380.3 "Combustion test of cables under flame conditions - Part 3. Test method for burning of bundled wires or cables" China's current flame retardant rubber insulated cable is developed at the actual level of development. This standard was proposed by the Fire Department of the Ministry of Public Security of the People's Republic This standard is under the jurisdiction of the 7th Technical Committee of the National Fire Protection Standardization Technical Committee (SAC/TC113/SC7). This standard is drafted by. Sichuan Fire Research Institute of the Ministry of Public Security. Participated in the drafting of this standard. Fire Department of Zhejiang Public Security Department, Shengwu Industrial Co., Ltd. The main drafters of this standard. Cheng Dabin, Li Feng, Feng Jun, Zhang Cai, Zhou Tian, Yang Shengwu. Flame retardant and fire resistant cable flame retardant rubber insulated cable grading and requirements1 ScopeThis standard specifies the definition, technical requirements, test methods, inspection rules, signs and packaging of flame retardant rubber insulated cables. This standard applies to flame retardant rubber insulated cables with rated voltages of 450/750V and below.2 Normative referencesThe terms in the following documents become the terms of this standard by reference to this standard. All dated references, followed by all Modifications (not including errata content) or revisions do not apply to this standard, however, parties to agreements based on this standard are encouraged to study Is it possible to use the latest version of these files? For undated references, the latest edition applies to this standard. GB/T 2951.1-1997 General test methods for cable insulation and sheathing materials - Part 1 GB 5013 Rubber insulated cable with rated voltage of 450/750V and below (idt IEC 245.1994) GB/T 18380.3 Burning test under flame conditions - Part 3. Burning test method for bundled wires or cables (idt IEC 60332-3.1992) JB8735 Rubber insulated cord and flexible cable with rated voltage of 450/750V and below3 Terms and definitionsThe following terms and definitions apply to this standard. 3.1 Rubber insulated cable with specified flame retardant properties. 4 Product model, flame rating and marking 4.1 Product model It shall comply with the requirements of Tables 1 and 2. 4.2 Flame retardant level The flame retardant grade is divided into three grades according to the flame retardant sample category, and the marks are A, B, and C, respectively. 4.3 mark 4.3.1 Flame retardant marking The flame retardant grade is labeled ZR. 4.3.2 Product Marking Flame-retardant rubber insulated cable with flame retardant marking, flame retardant grade marking, rubber insulated cable type, rated voltage, conductor nominal cross-sectional area and this The standard number indicates. Table 1 Rubber insulated cable type (GB 5013) Serial number name model 1 conductor with a maximum temperature of 180 ° C heat-resistant silicone rubber insulated cable 245IEC 03 (YG) 2 conductor maximum temperature 110 ° C 750V hard conductor heat-resistant ethylene - vinyl acetate rubber insulated single core non-conducting cable 245IEC 04 (YYY) ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GA 535-2005_English be delivered?Answer: Upon your order, we will start to translate GA 535-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GA 535-2005_English with my colleagues?Answer: Yes. The purchased PDF of GA 535-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |