CJ/T 30-2013: Thermocouple electromagnetic protector of extinguishment for gas appliance
Status: Valid

CJ/T 30: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
CJ/T 30-20131109 Add to Cart 7 days Thermocouple electromagnetic protector of extinguishment for gas appliance Valid
CJ 30-1999519 Add to Cart 4 days Thermocouple electromagnetic protector of extinguishment for gas appliance Obsolete
CJ/T 30-1991359 Add to Cart 3 days (Urban passenger vehicle repair general technical conditions) Obsolete

Similar standards

GB/T 13611   CJ/T 393   GB/T 16411   CJ/T 29   CJ/T 28   CJJ/T 55   

Basic data

Standard ID: CJ/T 30-2013 (CJ/T30-2013)
Description (Translated English): Thermocouple electromagnetic protector of extinguishment for gas appliance
Sector / Industry: Urban Construction Industry Standard (Recommended)
Classification of Chinese Standard: P45
Classification of International Standard: 91.140
Word Count Estimation: 45,498
Older Standard (superseded by this standard): CJ 30-1999
Quoted Standard: GB/T 191; GB/T 1019-2008; GB/T 3091; GB 4706.1; GB 4706.94; GB/T 4857.3; GB/T 4857.5; GB/T 7307; GB/T 9144; GB/T 12716; GB/T 13611; GB 14536.1-2008; GB/T 15092.1; GB/T 16411-2008; CJ/T 222-2006; GB/T 7306.1; GB/T 7306.2
Adopted Standard: BS EN 125-2010; MOD
Regulation (derived from): Department of Housing and Urban-Rural Development Bulletin No. 18; industry standard filing Notice 2013 No. 7 (No. 163 overall)
Issuing agency(ies): Ministry of Housing and Urban-Rural Development of the People's Republic of China
Summary: This standard specifies: thermoelectric Appliance flameout protection device terms and definitions, classification, structure and materials, requirements, test methods, inspection rules, marking, installation and operating instructions, packaging, transpo

CJ/T 30-2013: Thermocouple electromagnetic protector of extinguishment for gas appliance

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Thermocouple electromagnetic protector of extinguishment for gas appliance ICS 91.140 P45 People's Republic of China urban construction industry standards Replacing CJ 30-1999 Thermoelectric burner flameout protection device 2013-04-27 released 2013-10-01 Implementation Ministry of Housing and Urban-Rural Development, People's Republic of China released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 Categories 2 4.1 Flameout protection device classification 2 4.2 flameout protection device grouping 3 5 Structure and materials 3 5.1 Structure 3 5.2 Materials 5 5.3 gas connection 6 6 Requirements 8 6.1 General Requirements 8 6.2 Air tightness 8 6.3 Torsion and bending 9 6.4 rated flow 9 6.5 Durability 9 6.6 Functional Requirements 10 6.7 Durability 11 7 Test Method 12 7.1 Test conditions 12 7.2 Air tightness test 12 7.3 Torsion and Bending Tests 13 7.4 rated flow test 15 7.5 Durability test 16 7.6 Functional test 17 7.7 Durability test 20 8 Inspection Rules 21 8.1 General requirements 21 8.2 unqualified classification 21 9 Identification, installation and operating instructions 22 9.1 logo 22 9.2 Installation and Operating Instructions 22 9.3 Warnings 23 10 Packaging, transportation and storage 23 10.1 General requirements 23 10.2 Packaging 23 10.3 Transportation 24 10.4 Storage 24 Appendix A (informative) This standard and BSEN125..2010 compared to the structural changes 25 Appendix B (informative) This standard and BSEN125..2010 technical differences and their causes 28 Appendix C (informative) flameout protection device type and composition 30 Appendix D (informative) flame sensing thermocouple installation requirements 32 Appendix E (Normative) Flame-retardant protective devices using auxiliary energy special requirements 33 Appendix F (Informative) Solenoid single test method 34 Appendix G (Informative) Air tightness test --- volume method 36 Appendix H (informative) This standard supports the provisions of the basic requirements of GB 16914-2012 corresponding table 38 References 40

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces CJ 30-1999 "thermoelectric burner flameout protection device", compared with the CJ 30-1999, the main technical changes are as follows. --- Increased use of auxiliary energy thermoelectric burner flameout protection device (see Chapter 1, Appendix E); --- Increased torsion and bending, rated flow, operating characteristics and air tightness requirements (see 6.3,6.4,6.6.1,6.6.5); --- Modify the thermoelectric gas flameout protection device classification (see Chapter 4,.1999 edition of Chapter 4); --- Modify the valve opening time, valve closing time requirements (see 6.6.4,.1999 version 5.2.3); --- Deleted the establishment of models (see.1999 version 4.4); --- Removed the open valve current requirements (1999 version 5.2.2). This standard uses redrafted Law Amendment adopts BSEN125..2010 "gas appliance flame control device thermoelectric flame monitoring device." This standard and BSEN125..2010 compared to more structural adjustment, Appendix A lists the standard and BSEN125..2010 chapter Article number control list. This standard compared with BSEN125..2010 there are technical differences, the provisions of these differences have been passed in the outer margin of the page margin Set the vertical single line (︱) marked, Appendix B shows the corresponding technical differences and their causes list. This standard is consistent with GB 16914-2012 "gas burning appliances safety conditions," Appendix H gives the standard branch GB 16914-2012 with the basic requirements of the provisions of the corresponding table. This standard made the following editorial changes. --- Modify the standard name as "thermoelectric burner flameout protection device"; --- Removed BSEN125..2010 cover, directory, preface and description; --- Removed BSEN125..2010 Appendix A (informative) "countries commonly used gas connection"; --- Removed BSEN125..2010 Annex C (informative) "Gas tightness test --- pressure loss method"; --- Removed BSEN125..2010 Appendix D (normative) "pressure loss method converted into leakage"; --- Removed the BSEN125..2010 Appendix F (normative) "EU quality 97/23/EC in the safety Annex and pressure Additional requirements for attachments "; --- Removed BSEN125..2010 Appendix G (normative) "pressure parts material"; --- Removed BSEN125..2010 Appendix H (informative) "compression parts additional materials"; --- Removed BSEN125..2010 Appendix ZA (Informative) "on gas fuels EU standards and EC directives 2009/142/EC correspondence between; --- Added Appendix C (informative) "flameout protection device type and composition"; --- Added Appendix D (informative) "flame sensing thermocouple installation requirements"; --- Added Appendix E (normative) "use auxiliary energy flameout protection device special requirements"; --- Added Appendix F (informative) "Solenoid single test method." This standard proposed by the Ministry of Housing and Urban Standard and Design Institute. This standard by the Ministry of Housing and Urban Gas Standardization Technical Committee centralized. This standard was drafted. Zhejiang Siguo Precision Electrical Co., Ltd., Austrian can Electronics (Kunshan) Co., Ltd., the quality of national gas appliances Inspection Center, Ningbo Wanbao Electric Co., Ltd., Ningbo Okay Security Technology Co., Ltd., Zhongshan Chun Ye Jia Ante Appliance Co., Ltd. North China Municipal Engineering Design and Research Institute. The main drafters of this standard. Han Songhe, Li Wenqing, Pan Cuijing, Sun Weibao, Jiang Chunfei, Zong Wei, drainage Yanhong, Shen Haixia. This standard replaces the standards previously issued as follows. --- CJ 30-1999. Thermoelectric burner flameout protection device

1 Scope

This standard specifies the terms and definitions, classification, structure and material of the thermoelectric burner flameout protection device (hereinafter referred to as "flameout protection device") Materials, requirements, test methods, inspection rules, marking, installation and operating instructions, packaging, transportation and storage. This standard applies to indicate the maximum working pressure below 10kPa, the nominal connection size is not greater than DN50, and used in line with GB/T 13611 provisions of urban gas appliances with thermoelectric burner flameout protection device. This standard also applies to. --- By the thermoelectric power-driven, can be individually tested for the thermoelectric ignition flameout protection device solenoid valve; --- flame sensing thermocouple; --- The use of auxiliary energy thermoelectric burner flameout protection devices (such as externally supplied electricity).

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 191 Packaging - Pictorial signs (GB/T 191-2008, ISO 780..1997, MOD) GB/T 1019-2008 Household and similar electrical appliances packaging General GB/T 3091 welded steel pipe for delivery of low-pressure fluid (GB/T 3091-2008, ISO 559..1991, NEQ) GB 4706.1 Household and similar electrical appliances - Safety Part 1. General requirements (GB 4706.1-2005, IEC 60335-1. 2004 (Ed4.1), IDT) GB 4706.94 Safety of household and similar electrical appliances Electrical connections to the use of gas, fuel and solid fuel appliances Special Special requirements (GB 4706.94-2008, IEC 60335-2-102..2004, IDT) GB/T 4857.3 Packaging - Transport packages - Basic test - Part 3. Static load stacking test method (GB/T 4857.3-2008, ISO 2234..2000, IDT) GB/T 4857.5 package transport package drop test method (GB/T 4857.5-1992, eqvISO 2248. 1985) GB/T 7306 (all parts) 55 ° sealing pipe thread GB/T 7307 55 ° non-sealed pipe thread (GB/T 7307-2001, eqvISO 228-1..1994) GB/T 9144 ordinary thread preferred series (GB/T 9144-2003, ISO 262..1998, MOD) GB/T 12716 60 ° sealing pipe thread GB/T 13611 urban gas classification and basic characteristics GB 14536.1-2008 Household and similar electrical automatic controllers - Part 1. General requirements (IEC 60730-1..2003 (Ed3.1), IDT) GB/T 15092.1 appliance switches - Part 1. General requirements (GB 15092.1-2010, IEC 61058-1..2008 (Ed.3.2), IDT) Household gas appliances GB/T 16411-2008 General test methods Domestic gas burning appliances conformity assessment procedures and acceptance rules
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of CJ/T 30-2013_English be delivered?

Answer: Upon your order, we will start to translate CJ/T 30-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of CJ/T 30-2013_English with my colleagues?

Answer: Yes. The purchased PDF of CJ/T 30-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version CJ/T 30-2013?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version CJ/T 30-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.