Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

CJ/T 250-2018 English PDF

US$879.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email.
CJ/T 250-2018: High density polyethylene pipes and fittings for drainage inside buildings
Status: Valid

CJ/T 250: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
CJ/T 250-2018879 Add to Cart 6 days High density polyethylene pipes and fittings for drainage inside buildings Valid
CJ/T 250-2007RFQ ASK 6 days High density polyethylene pipes and fittings for drainage inside buildings Obsolete

Similar standards

GB/T 18920   GB/T 18921   GB/T 18919   CJ/T 245   CJ/T 256   CJJ/T 250   

Basic data

Standard ID: CJ/T 250-2018 (CJ/T250-2018)
Description (Translated English): High density polyethylene pipes and fittings for drainage inside buildings
Sector / Industry: Urban Construction Industry Standard (Recommended)
Classification of Chinese Standard: P40
Word Count Estimation: 38,375
Date of Issue: 2018-10-30
Date of Implementation: 2019-04-01
Older Standard (superseded by this standard): CJ/T 250-2007
Regulation (derived from): Ministry of Housing and Urban-Rural Development Announcement 2018 No. 245
Issuing agency(ies): Ministry of Housing and Urban-Rural Development of the People's Republic of China

CJ/T 250-2018: High density polyethylene pipes and fittings for drainage inside buildings

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(High-density polyethylene (HDPE) pipes and fittings for building drainage) People's Republic of China urban construction industry standards Replace CJ/T 250-2007 High density polyethylene (HDPE) for building drainage Pipe and fittings [ISO 8770.2003, Plasticspipingsystemsforsoilandwastedischarge(lowand Published on.2018-10-30 Implementation of.2019-04-01 Ministry of Construction of the People's Republic

Content

Foreword I 1 Scope 1 2 Normative references 1 3 Terms and definitions, symbols and abbreviations 1 4 Material 3 5 Product Categories and Specifications 3 6 requirement 8 7 Test method 10 8 Inspection rules 11 9 Marking, packaging, transport and storage 12 Appendix A (normative appendix) EN1055.1996 temperature rise cycle test 14 Appendix B (informative) Pipe fitting size 20 Appendix C (informative) Relationship between tube series and temperature and working pressure 30 Appendix D (Normative Appendix) Impact Strength Test 31 Appendix E (Normative Appendix) Welding Strength Test 34

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces CJ/T 250-2007 "High Density Polyethylene (HDPE) Pipe and Fittings for Building Drainage", from the date of implementation of this standard CJ/T 250-2007 is abolished. Compared with CJ/T 250-2007, the main technical changes except editorial changes are as follows. --- Increase the normative reference document GB/T 18992.2 (see Chapter 2); --- Replace EN1053.1995 and EN1054.1995 with GB/T 5836.1 (see Chapter 2); --- Increase the English translation of the term (see 3.1); --- Increase PE compounding (see 3.1.2); --- Increased the basic performance of "PE100" (see 4.1); --- Modified the icon and dimensions of Soweto (see 5.2.1); --- Modify the scope of compliance with EPDM (see 5.2.5); --- Increase the out-of-roundness of the pipe (see 6.3.1.4); --- Increase the vacuum test requirements in Table 8 (see 6.4) --- Added H-connector diagram and dimensions (see B.19); --- Increased the illustration and size of the riser vent cap (see B.19); --- Added P-type trap shape and size (see B.20); --- Added S-type trap illustration and size (see B.21); --- Increased impact strength test (see Appendix D); --- Increased weld strength test (see Appendix E). This standard practical redrafting method is modified to adopt ISO 8770.2003 "plastic pipes for sewage discharge (low temperature and high temperature) in buildings) System---polyethylene (PE), the degree of consistency between this standard and ISO 8770.2003 is non-equivalent. Compared with ISO 8770.2003, the technical differences between this standard and ISO 8770.2003 are as follows. ---ISO 8770.2003 high-density polyethylene pipes and fittings for building drainage are connected by butt welding, electrofusion and Socket connection, etc. The connection methods adopted in this standard are mainly butt welding and electrofusion, and the socket connection is only suitable for expansion and extension. Snap and seal adapters. --- For the application range of high-density polyethylene pipe for building drainage, this standard specifies the discharge of sewage, wastewater and rainwater from buildings. application. This standard was proposed by the Institute of Standardization of the Ministry of Housing and Urban-Rural Development. This standard is under the jurisdiction of the Building Water Supply and Drainage Standardization Technical Committee of the Ministry of Housing and Urban-Rural Development. This standard is mainly drafted by. Shanghai Jiboli Housing Sanitary Equipment Engineering Technology Co., Ltd., Shanghai Architectural Design and Research Institute Co., Ltd. Division, Shanghai Minghao Technology Industrial Co., Ltd., Xidi International Design Consultant (Shenzhen) Co., Ltd., Zhejiang Weixing New Building Materials Co., Ltd. The main drafters of this standard. Xu Feng, Jiang Wenyuan, Huang Baoyuan, Zhu Jianrong, Zhao Jun, Bao Hong, Yi Yimin, Lu Ping, Sun Wei, Wang Chunyang, Yu Zhigen, Du Weiguo, Zhang Wei. The previous versions of the standards replaced by this standard are. ---CJ/T 250-2007. High density polyethylene (HDPE) for building drainage Pipe and fittings

1 Scope

This standard stipulates the use of polyethylene resin as the main raw material, extruded pipe and mold forming or secondary processing of pipe fittings. Materials, product classification and specifications, requirements, test methods, inspection rules, marking, packaging, transportation and storage. This standard applies to high-density polyethylene (HDPE) pipes and fittings for building sewage, wastewater, and storm water discharge systems. The high-density polyethylene pipe specified in this standard is suitable for the drainage temperature range of 0 °C ~ 65 °C, and the instantaneous drainage temperature does not exceed 95 °C; For ambient temperature of -40 ° C ~ 65 ° C.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 2828.1. Sampling procedures for sampling by sampling - Part 1 . Batch-to-batch sampling plan, searched by AQL Standard environment for GB/T 2918 plastic sample conditioning and testing GB/T 3682 Determination of melt flow rate and melt volume flow rate of thermoplastics GB/T 5836.1-2018 Hard polyvinyl chloride (PVC-U) pipe for building drainage GB/T 6111 Test method for internal pressure resistance of thermoplastic pipes for fluid transportation GB/T 6671 Determination of the longitudinal retraction rate of thermoplastic pipes GB/T 8805 Hard plastic pipe bending method GB/T 8806 Plastic pipe system - Determination of dimensions of plastic parts GB/T 9647 Determination of the stiffness of thermoplastic pipe rings GB/T 13021 Determination of carbon black content of polyethylene pipes and fittings (thermal weight loss method) GB/T 17391 polyethylene pipe and pipe fittings thermal stability test method GB/T 18251 Determination of pigment or carbon black dispersion in polyolefin pipes, fittings and mixes GB/T 18992.2 Cross-linked polyethylene (PE-X) piping systems for cold and hot water - Part 2 GB/T 21873 Rubber seals, drain pipes and sewage pipes for interface seal material specifications GJB1916 General Specification for Low Smoke Cables and Cords for Ships (Toxicity Index Test) ISO 8770.2003 Plastics piping systems for the discharge of waste water (low temperature and high temperature) in buildings (PE) ISO /T R7024.1985 Floor draining of rigid polyvinyl chloride (PVC-U) sanitary plumbing systems for above-ground systems in buildings Installation technology and practices EN681-1 - Elastomeric sealing materials for draining joints - Part 1 . Vulcanized rubber EN1055.1996 Plastic pipe system for the test of temperature rise cycle of thermoplastic piping systems for the discharge of sewage from buildings Test method 3 Terms and definitions, symbols and abbreviations The following terms and definitions, symbols and abbreviations apply to this document.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of CJ/T 250-2018_English be delivered?

Answer: Upon your order, we will start to translate CJ/T 250-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of CJ/T 250-2018_English with my colleagues?

Answer: Yes. The purchased PDF of CJ/T 250-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version CJ/T 250-2018?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version CJ/T 250-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.