GBZ41476.1-2022 English PDFUS$219.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GBZ41476.1-2022: Non-destructive testing instruments - Radiation protection rules for the technical application of X-ray equipment up to 1 MV - Part 1: General safety technical requirements Status: Valid
Basic dataStandard ID: GB/Z 41476.1-2022 (GB/Z41476.1-2022)Description (Translated English): Non-destructive testing instruments - Radiation protection rules for the technical application of X-ray equipment up to 1 MV - Part 1: General safety technical requirements Sector / Industry: National Standard Classification of Chinese Standard: N78 Word Count Estimation: 9,981 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GBZ41476.1-2022: Non-destructive testing instruments - Radiation protection rules for the technical application of X-ray equipment up to 1 MV - Part 1: General safety technical requirements---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. GB /Z 41476.1-2022 Non-destructive testing instruments -- Radiation protection rules for the technical application of X-ray equipment up to 1 MV -- Part 1.General safety technical requirements ICS 19.100 CCSN78 National Standardization Guiding Technical Document of the People's Republic of China Non-destructive testing equipment X-ray below 1MV Radiation Protection Regulations for Equipment Part 1. General safety technical requirements Published on 2022-04-15 2022-11-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration directory Preface III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 General safety technical requirements 1 5 Logo 4 forewordThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents" drafted. This document is part 1 of GB /Z 41476 "Rules for Radiation Protection of X-ray Equipment Below 1MV for Nondestructive Testing Instruments". GB /Z 41476 has published the following parts. --- Part 1.General safety technical requirements; --- Part 2.Technical requirements for protection; --- Part 3.Calculation formulas and charts for radiation protection of X-ray equipment below 450kV; --- Part 4.Calculation of the control area. Please note that some content of this document may be patented. The issuing agency of this document assumes no responsibility for identifying patents. This document is proposed by China Machinery Industry Federation. This document is under the jurisdiction of the National Standardization Technical Committee of Testing Machines (SAC/TC122). This document is drafted by. Liaoning Instrument Research Institute Co., Ltd., Shenzhen China Test Testing Co., Ltd., Edson (Xiamen) Electronics Co., Ltd. Co., Ltd., General Electric Detection and Control Technology (Shanghai) Co., Ltd., Guangdong Zhengye Technology Co., Ltd., Zhongshan Vocational and Technical College. The main drafters of this document. Xu Bo, Liu Panchao, Lin Junming, Kong Fanqin, Sheng Zhoulin, Fuyang, Wang Lin.IntroductionX-rays are electromagnetic waves with extremely short wavelengths and high energy, and their wavelengths are shorter than those of visible light. As five routine detection methods One, X-ray detection has been widely used in industrial non-destructive testing. Because of its strong penetration, it will cause certain damage to the body of the inspector. The safety protection problem in this X-ray inspection has received extensive attention. GB /Z 41476 aims to establish protection requirements for X-ray equipment below 1MV And personnel safety protection rules, it is proposed to be composed of 4 parts. --- Part 1.General safety technical requirements. The purpose is to give the dose limit for personnel in the operation of X-ray equipment below 1MV, Equipment usage requirements, etc. --- Part 2.Technical requirements for protection. The purpose is to provide effective, Reliable radiation protection measures. --- Part 3.Calculation formulas and charts for radiation protection of X-ray equipment below 450kV. The purpose is to give below 405kV The calculation formulas and related charts of the main technical indicators of X-ray equipment protection are convenient for the calculation of relevant data in the process of X-ray protection. --- Part 4.Calculation of the control area. The purpose is to provide a calculation method for the control area of X-ray equipment below 1MV, and for the third Some content is further supplemented. Non-destructive testing equipment X-ray below 1MV Radiation Protection Regulations for Equipment Part 1. General safety technical requirements1 ScopeThis document specifies the dose limits for the protection of X-ray nondestructive testing equipment below 1MV, the control area and supervision area, the use of X-ray equipment Use requirements and logos. This document applies to the safety protection of X-ray non-destructive testing equipment below 1MV.2 Normative referencesThe contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document. GB 18871-2002 Basic standard for ionizing radiation protection and radiation source safety GB /Z 41476.3 Non-destructive testing instruments radiation protection rules for X-ray equipment below 1MV Part 3.below 450kV Calculation formulas and charts for radiation protection of X-ray equipment GB /Z 41476.4 Radiation protection rules for X-ray equipment below 1MV of non-destructive testing instruments Part 4.Controlled area calculate3 Terms and DefinitionsThere are no terms and definitions that need to be defined in this document.4 General safety technical requirements4.1 Dose Limits Radiation precautions are used to avoid all unnecessary X-ray exposure. Personal dose limits should be in accordance with Table 1. Other ionizing radiation in the occupation of radiation workers should also be included in the measurement of radiation precautions, the body dose value should not exceed Limits in the corresponding ionizing radiation protection regulations. Table 1 Dose limits in X-ray exposure crowd dose limit mSv occupational exposure personnel Annual effective dose Annual equivalent dose of eye lens Limbs (hands and feet) or skin annual equivalent dose 20a ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GBZ41476.1-2022_English be delivered?Answer: Upon your order, we will start to translate GBZ41476.1-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GBZ41476.1-2022_English with my colleagues?Answer: Yes. The purchased PDF of GBZ41476.1-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |