GBZ35588-2017 English PDFUS$414.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GBZ35588-2017: Measurement of wet gas flow by means of pressure differential devices inserted in circular cross-section conduits Status: Valid
Basic dataStandard ID: GB/Z 35588-2017 (GB/Z35588-2017)Description (Translated English): Measurement of wet gas flow by means of pressure differential devices inserted in circular cross-section conduits Sector / Industry: National Standard Classification of Chinese Standard: N12 Classification of International Standard: 17.120.10 Word Count Estimation: 22,277 Date of Issue: 2017-12-29 Date of Implementation: 2018-07-01 Regulation (derived from): National Standards Bulletin 2017 No. 32 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GBZ35588-2017: Measurement of wet gas flow by means of pressure differential devices inserted in circular cross-section conduits---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Measurement of wet gas flow by means of pressure differential devices inserted in circular cross-section conduits ICS 17.120.10 N12 People's Republic of China national standardization of technical guidance documents With the installation of circular cross-section of the pipe in the differential pressure device Measure wet gas flow (ISO /T R11583.2012, IDT) 2017-12-29 Posted 2018-07-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released ForewordThis instructional document has been drafted in accordance with the rules given in GB/T 1.1-2009. This guideline uses the translation method identical with ISO /T R11583.2012 "with a differential pressure mounted in a circular sectioned pipe Set the measurement of wet gas flow. " Our document, which corresponds in a consistent manner to the international documents that are normative references in this Guidance Document, is as follows. --- GB /Z 35140-2017 fluid flow measurement using differential pressure device GB/T 2624 outside the area of the orifice, nozzle and venturi Guidelines for using tubes (ISO /T R15377.2007, IDT) --- GB/T 17611-1998 Measurement of fluid flow in closed conduits Terms and symbols (idtISO 4006.1991) --- GB/T 26801-2011 closed pipe fluid flow measurement between the primary device and secondary device pressure signal transmission Connection Method (ISO 2186.2007, IDT) This guidance document is proposed by China Machinery Industry Federation. This Guidance Document is governed by the National Technical Committee for Measurement, Control and Automation of Industrial Processes (SAC/TC124). The guiding technical document is drafted by Shanghai Institute of Industrial Automation Instrumentation. The guidance of technical documents to participate in the drafting unit. Beijing Ruipu ternary Instrument Co., Ltd., Jiangyin City, throttling Plant Co., Ltd., Zhejiang Cangnan Instrument Group East Star Energy Technology Co., Ltd., Zhejiang Tianxin Instrument Technology Co., Ltd., Shanghai Instrumentation Automatic Control System Test By, Dandong Tongbo Electric Group, Zhejiang Jinlong Control Equipment Co., Ltd. The main drafters of this technical guidance document Xiao Hong Lian, Li Zhenzhong, Yan Yongfeng, Xie Shangpeng, Chen Weigang, Song Yan Yong, Guo Yonggang, Li Minghua, Wang Jianing, Yu Jinhai.IntroductionPart 1 of GB/T 2624-2006 "Measurement of Manifold Fluid Flow with Differential Pressure Devices Installed in Circular Cross-Sectional Ducts", Part 2 Section 4 and Section 4 contain provisions for venturi and orifice plates, but only for the measurement of full pipe single phase fluids. If the measured fluid is a wet gas, it will produce "virtual high", which can be corrected by the corresponding wet gas correction equation. With the installation of circular cross-section of the pipe in the differential pressure device Measure wet gas flow1 ScopeThis guidance document provides a method for measuring the flow of wet gas using a differential pressure device installed in a circular sectioned pipe. This guidance is applicable to gas-liquid two-phase mixed fluids (6.4.3, 6.4.5, 7.5.3) with a gas volume percentage of 95% or more And 7.5.5 gives a clear limitation of the mixed fluid). This Guidance Document is a supplement to GB/T 2624. 6.4.1 and 7.5.1 to The range of gases and liquids used for the derivation of the formulas in this guidance is presented. These formulas may not be suitable for use with test liquids Different liquids, especially high viscosity liquids. Although the correction formulas given in this guidance document are applicable to most gases and liquids with comparable gas-liquid density ratios, For gas flow, not only is it necessary to evaluate the information required for a single-phase fluid, but also other information is needed. Under some conditions it is only necessary to measure the pressure loss The tracer can be used to measure the flow of liquid; the total mass flow of the fluid is known (as compared to natural gas/liquid fluids, wet steam fluids are more likely to have This requirement); dampening calorimeters can be used in wet steam fluids. This guidance document includes the measurement of wet gas using a venturi or orifice plate. This guidance document is applicable only to wet gas containing one liquid and is not suitable for use in the oil and gas industry.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 2624.1-2006 Measurement of full pipe fluid flow using differential pressure devices installed in circular sectioned pipes - Part 1. General Principles and requirements (ISO 5167-1.2003, IDT) GB/T 2624.2-2006 Measurement of full pipe fluid flow using a differential pressure device installed in a circular sectioned pipe - Part 2 - Orifice (ISO 5167-2.2003, IDT) GB/T 2624.4-2006 Manifold fluid flow measurement using differential pressure devices installed in circular sectioned pipes - Part 4 Ventura In tube (ISO 5167-4.2003, IDT) ISO 2186 Measurement of fluid flow in closed conduits Connection of pressure signals between primary and secondary units (Fluid flowinclosedconduits-Connectionsforpressuresignaltransmissionsbetweenprimaryandsecondary elements ISO 4006 closed pipe fluid flow measurement terms and symbols (Measurementoffluidflowinclosedcon- duits-Vocabularyandsymbols) ISO /T R15377 Fluid Flow Measurement with Differential Pressure Devices Use of Orifices, Nozzles and Venturi Beyond ISO 5167 Guideline (Measurementoffluidflowbymeansofpressure-differentialdevices-Guidelinesforthespecifi- cationoforificeplates, nozzlesandVenturitubesbeyondthescopeofISO 5167)3 Terms and definitionsISO 4006 and GB/T 2624.1-2006 define the following terms and definitions apply to this document. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GBZ35588-2017_English be delivered?Answer: Upon your order, we will start to translate GBZ35588-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GBZ35588-2017_English with my colleagues?Answer: Yes. The purchased PDF of GBZ35588-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |