Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GBZ22721-2008 English PDF

US$474.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GBZ22721-2008: Guidance for the correct use of residual current-operated protective devices (RCDs) for household and similar use
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/Z 22721-2008474 Add to Cart 4 days Guidance for the correct use of residual current-operated protective devices (RCDs) for household and similar use Valid

Similar standards

GB/T 22794   GB 16916.1   GB 29303   GB/T 13539.7   GB/T 13539.6   GB/T 17701   

Basic data

Standard ID: GB/Z 22721-2008 (GB/Z22721-2008)
Description (Translated English): Guidance for the correct use of residual current-operated protective devices (RCDs) for household and similar use
Sector / Industry: National Standard
Classification of Chinese Standard: K31
Classification of International Standard: 29.120.50
Word Count Estimation: 24,212
Date of Issue: 2008-12-30
Date of Implementation: 2009-10-01
Adopted Standard: IEC/TR 62350-2006, IDT
Regulation (derived from): ?National Standard Approval Announcement 2008 No.23 (Total No.136)
Issuing agency(ies): Ministry of Health of the People's Republic of China
Summary: This standard specifies the summary provided by the household and similar purposes in line with national standards residual current operated protective devices (RCD) protection availability. This standard describes the focus of the main parameters affecting the availability of protection. And provides information on how to install and use the information and after the installation RCD environmental conditions. This standard gives a fixed electrical installations relating to the availability and protection during use (installation and maintenance) how to maintain a high level of protection of the general availability of information, the development of standards for each benefit Standardization Technical Committee, installers, inspection and users. Note 1: The term is applied to a RCD when RCD residual current is equal to or exceeds the rated residual operating current I �� n to automatically disconnect the product family.

GBZ22721-2008: Guidance for the correct use of residual current-operated protective devices (RCDs) for household and similar use


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Guidance for the correct use of residual current-operated protective devices (RCDs) for household and similar use ICS 29.120.50 K31 People's Republic of China national standardization of technical guidance documents GB /Z22721-2008/IEC /TR62350..2006 Correct use of household and similar use of residual current action Guide to Protective Electrical Appliances (RCDs) (IEC /T R62350..2006, IDT) Posted.2008-12-30 2009-10-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Preface Ⅰ Introduction Ⅱ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 General information on the availability of RCD protection 2 5 Information on the role of products in protecting usability 4 Protection availability of electrical installations with RCDs 5 7 Information on site installation and use of the RCD 8 Appendix A (Informative) General Illustrations to Help Usability of Protective Measures 13 Appendix B (informative) Terms and definitions selected from IEV 14 Appendix C (Informative) RCD action possible fault current 16 Appendix D (informative) test button usage example 18 References 19 GB /Z22721-2008/IEC /TR62350..2006

Foreword

This technical document is equivalent to the use of IEC /T R62350..2006 "Correct use of household and similar residual current protection circuit (RCD) Guide ", in accordance with the format GB/T 1.1-2000 requirements, made editorial changes. Appendices A, B, C and D of this guidance document are informative appendices. This guidance document is proposed by China Electrical Equipment Industry Association. The guidance of technical documents by the National Standardization Technical Committee of low-voltage electrical (SAC/TC189) centralized. This Guidance Document is drafted by. Shanghai Electric Apparatus Research Institute (Group) Co., Ltd. Participated in the drafting of this technical documents. Nanjing Electric Power College, Schneider Electric (China) Investment Co., Ltd., Deli West Electric Co., Ltd., Universal Group Co., Ltd., Beijing People's Electric Factory. The main drafters of this technical guidance document. Liu Jinyan, Zhou Gang. Drafters of this Guidance Document. Li Jiasian, Feng Ding, Huang Rongrong, Li Lifang and Zhao Zhiqun. This guidance document is the first to be released. GB /Z22721-2008/IEC /TR62350..2006

Introduction

The purpose of this guidance document is to provide designers, manufacturers, and installers with a view to optimizing the long-term availability of protection provided by the RCD As well as users and guides and information for maintenance personnel responsible for the selection, installation and use of RCDs in fixed electrical installations. In the last 40 years, the IEC Technical Committee (inter alia, within SC23E) has compared and used the data collected by manufacturers, laboratories, installers, The experience accumulated by users and installers, the IEC has made progress on RCD reliability by revising the RCD standard. Around this goal Standard, the technical requirements and tests of these IEC standards have been added and improved. When SC23E decided to introduce such as analog RCD aging 28 days environmental testing and other technical requirements, it has made considerable progress. The user, installer, and other committees of the IEC are required to inform the IEC that while compared to the earlier RCD, while meeting the relevant RCD standards RCD reliability has been substantially improved, but the availability of protection provided by RCDs is related to many parameters, not only with the RCD itself Off, but also with the installation and use of the environment. This guidance document comprehensively identifies and describes the main factors affecting the availability of RCD protection in order to further promote RCD Operate reliably and enhance the valuable protection provided by this appliance. In order to implement this step by step through the publication of the technical guide The work already done by the SC23E will continue to monitor this important area (reliability). Additional Information. During the meeting between TC64 and SC23E officials, confirm that this Guidance Document does not conflict with the TC64 standard There are contradictions, and the purpose of this guidance document is to provide information for better understanding and proper use of the RCD. GB /Z22721-2008/IEC /TR62350..2006 Correct use of household and similar use of residual current action Guide to Protective Electrical Appliances (RCDs)

1 Scope

This technical note provides the residual current operated protective device (RCD) provided by the national standard for household and similar purposes A summary of the availability of protection. This guidance document highlights key parameters that affect the availability of protection and provides guidance on Information on how to install and use the RCD and the environmental conditions after installation. This Guidance Document gives information on the availability of protection in fixed electrical installations and how high (during installation and maintenance) General information about the level of protection availability available; the development of this technical guidance document is useful to all standardization technical committees, installers, inspections And users. Note 1. The term RCD is a general purpose family of products that can be automatically switched off when the residual current equals or exceeds the rated residual operating current IΔn of the RCD the term. This general term applies generally to. RCCB --- residual current circuit breaker without over-current protection; RCBO --- residual current circuit breaker with overcurrent protection; SRCD --- outlet residual current electrical appliances; PRCD --- mobile residual current appliances. The difference between RCCB and RCBO is that RCBO has added over-current protection function, while RCCB has no protection against over-current. NOTE 2 PRCDs are not considered part of a fixed electrical installation and are therefore not covered by this technical document.

2 Normative references

The following documents contain provisions which, through reference in this Guidance Document, become the provisions of this Guidance Note document. All dated Reference documents, all subsequent amendments (not including errata content), or revisions do not apply to this guidance document, however, drums Recipients of the agreement based on this guidance document are encouraged to study whether the latest versions of these documents are applicable. All undated references The latest version of this document applies to this guidance document. GB 16895 (all parts) building electrical installations GB/T 16895.16-2002 Electrical installations in buildings - Part 4. Safety protection Chapter 44. Overvoltage protection Regulation 444 Section. Electromagnetic Interference (EMI) Protection of Building Electrical Installations (IEC 60364-4-444..1996, IDT) GB/T 16895.18-2002 Electrical installations in buildings - Part 5. Selection and installation of electrical equipment Chapter 51. General regulations Then (IEC 60364-5-51..1997, IDT) GB 16916 (all parts) Residual current operated circuit breakers (RCCB) for household and similar purposes without overcurrent protection GB 16916.1-2003 Residual current operated circuit breakers without overcurrent protection (RCCB) for household and similar purposes Part 1 Points. General rules (IEC 61008-1..1996, MOD) GB 16917 (all parts) Residual current operated circuit breaker (RCBO) with overcurrent protection for household and similar purposes GB 16917.1-2003 Residual current operated circuit breakers (RCBO) with overcurrent protection for household and similar purposes Part 1 Points. General rules (IEC 61009-1..1996, MOD) GB/T 17045-2006 Shock protection devices and equipment common part (IEC 61140..2001, IDT) GB 18499-2008 Residual Current Actuators (RCDs) for Household and Similar Use Electromagnetic Compatibility (IEC 61543. 1995, IDT) GB /Z22721-2008/IEC /TR62350..2006
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GBZ22721-2008_English be delivered?

Answer: Upon your order, we will start to translate GBZ22721-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GBZ22721-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GBZ22721-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.