Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 9246-2008 English PDF

US$229.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 9246-2008: Microscopes -- Oculars (eyepieces)
Status: Valid

GB/T 9246: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 9246-2008229 Add to Cart 3 days Microscopes -- Oculars (eyepieces) Valid
GB/T 9246-1996239 Add to Cart 2 days Microscopes--Oculars (eyepieces) Obsolete
GB 9246-1988RFQ ASK 3 days Microscopes--Series of oculars (eyepieces) Obsolete

Similar standards

GB/T 22062   GB/T 17360   GB/T 32387   GB/T 2609   GB/T 9247   

Basic data

Standard ID: GB/T 9246-2008 (GB/T9246-2008)
Description (Translated English): Microscopes -- Oculars (eyepieces)
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: N32
Classification of International Standard: 37.020
Word Count Estimation: 10,188
Date of Issue: 2008-06-20
Date of Implementation: 2009-01-01
Older Standard (superseded by this standard): GB/T 9246-1996
Quoted Standard: GB/T 15464; GB/T 22056; GB/T 22057.1; GB/T 22057.2; GB/T 22059; GB/T 22132
Regulation (derived from): Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the basic parameters of the microscope eyepiece, requirements, test methods and marking. This standard applies to microscope eyepiece.

GB/T 9246-2008: Microscopes -- Oculars (eyepieces)

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Microscopes. Oculars (eyepieces) ICS 37.020 N32 National Standards of People's Republic of China Replacing GB/T 9246-1996 Microscope eyepiece Posted 2008-06-20 2009-01-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard is the result of the "microscope eyepieces" basis GB/T 9246-1996 on the revised supplement made. This standard and GB/T 9246-1996 The main differences are as follows. --- Canceled photography eyepiece, eyepiece projection in the range; --- Press the number of categories in the field of view, an increase of ultra-wide field eyepiece; pressing the aberration correction increases the state is divided into ordinary eyepiece flat field eyepiece; increase Added classified according to the exit pupil distance is divided into ordinary and high eye point eyepiece eyepiece; --- Eyepiece eyepiece with separate pairs, highlighting the requirement for a pair of eyepiece binocular microscope; the two eyepiece optical axis And coaxial with the outer diameter of the requirement of "point of view" expressed and defined as 8 '; and increase the eyepiece diopter with the diopter indication "zero Bit "requirement; increased the flat-field eyepiece performance requirements; high eye point eyepiece determine the effective exit pupil distance should not be less than 18mm; --- The test tool "eyepiece comprehensive performance tester" with "focal length, microscope frame, micrometer, 10 ×/40 × objective lens, the front telescope Mirror frame and the diopter and connecting pipe "and other conventional instrument. The standard proposed by China Machinery Industry Federation. This standard by the National Standardization Technical Committee photon science and optics (SAC/TC103) centralized. This standard was drafted. Nanjing East to facilitate photoelectric Industrial Co., Ltd., Shanghai Polytechnic University, Shanghai Institute of optical instruments, Nanjing Jiangnan Yong New Optical Co. The main drafters of this standard. Yang Guanglie, Hu Hao, Huang Weijia, Hu Yu, Li . This standard replaces the standards previously issued as follows. --- GB 9246-1988, GB/T 9246-1996. Microscope eyepiece

1 Scope

This standard specifies the basic parameters of the microscope eyepiece, requirements, test methods and marking. This standard applies to the microscope eyepiece.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 15464 instrumentation packaging technology GB/T 22056 and the eyepiece of the microscope objective signs (GB/T 22056-2008, ISO 8578.1997, MOD) Imaging distance GB/T 22057.1 microscope to mechanical reference planes - Part 1. Tube length 160mm (GB/T 22057.1- 2008, ISO 9345-1.1996, MOD) GB/T 22057.2 Microscope Imaging distances related to mechanical reference planes - Part 2. Infinity corrected optical system (GB/T 22057.2-2008, ISO 9345-2.2003, MOD) GB/T 22059 microscope magnification (GB/T 22059-2008, ISO 8039.1997, IDT) GB/T 22132 interchangeable microscope eyepiece diameter (GB/T 22132-2008, ISO 10937.2000, MOD)

3 Classification and basic parameters

3.1 microscope eyepiece field number can be divided by ordinary eyepieces, wide field eyepieces and ultra-wide field eyepiece. 3.2 microscope eyepiece field of view by the aberration correction state can be divided into ordinary eyepiece flat field eyepiece. They can be divided into the objective lens has a complement Compensation effect and no compensation (ie, independent aberration correction) eyepiece. 3.3 microscope eyepiece exit pupil distance can be divided by high eye point eyepiece and eyepiece general. 3.4 eyepiece magnification shall comply with GB/T 22059 of. Interchangeable eyepieces with an outer diameter of 3.5 shall comply with GB/T 22132 of. 3.6 Observation eyepiece parfocal distance should comply with GB/T 22057.1 ~ 22057.2 of. 3.7 observe the eyepiece field number shall comply with the requirements in Table 1. Table 1 Classified minimum field number/mm Common eyepiece

4 Requirements

4.1 eyepiece magnification deviation shall not exceed ± 5%.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 9246-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 9246-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 9246-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 9246-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 9246-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 9246-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.