Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 9089.4-2008 English PDF

US$194.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 9089.4-2008: Electrical installations for outdoor sites under heavy conditions -- Part 4: Requirements for the installation
Status: Valid

GB/T 9089.4: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 9089.4-2008194 Add to Cart 3 days Electrical installations for outdoor sites under heavy conditions -- Part 4: Requirements for the installation Valid
GB/T 9089.4-1992359 Add to Cart 3 days Electrical installations for outdoor sites under heavy conditions. Repuirements for the installation Obsolete

Similar standards

GB/T 4706.53   GB/T 4706.48   GB 4706.48   GB/T 9089.3   GB/T 9089.2   GB/T 9089.1   

Basic data

Standard ID: GB/T 9089.4-2008 (GB/T9089.4-2008)
Description (Translated English): Electrical installations for outdoor sites under heavy conditions -- Part 4: Requirements for the installation
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K09
Classification of International Standard: 29.020
Word Count Estimation: 10,134
Date of Issue: 2008-06-18
Date of Implementation: 2009-03-01
Older Standard (superseded by this standard): GB/T 9089.4-1992
Quoted Standard: GB/T 9089.1-2008; GB/T 9089.2-2008; GB/T 9089.3-2008; GB 9089.5-2008
Adopted Standard: IEC 60621-4-1981, IDT
Regulation (derived from): Announcement of Newly Approved National Standards No. 10 of 2008 (total 123)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the conditions under harsh outdoor electrical installations equipment requirements to ensure that people, animals, property, security and normal operation of equipment. This section applies to harsh outdoor conditions (including mine, quarry, storage yard and similar) mining, stacker, primary processing machinery and conveyor systems and other electrical facilities. GB/T 9089. 1-2008 range applicable to this section.

GB/T 9089.4-2008: Electrical installations for outdoor sites under heavy conditions -- Part 4: Requirements for the installation


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electrical installations for outdoor sites under heavy conditions Part 4. Requirements for the installation ICS 29.020 K09 National Standards of People's Republic of China GB/T 9089.4-2008/IEC 60621-4. 1981 Replacing GB/T 9089.4-1992 Electrical installations for outdoor sites under heavy conditions Part 4. Installation Requirements (IEC 60621-4. 1981, IDT) Posted 2008-06-18 2009-03-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

GB/T 9089 "Electrical installations for outdoor sites under heavy conditions" series of standards are divided into the following parts. --- Part 1. Scope and definitions; --- Part 2. General protection requirements; --- Part 3. General requirements for equipment and accessories; --- Part 4. equipment requirements; --- Part 5. Operational requirements. This section GB/T 9089 series of standards Part 4, under identical with IEC 60621-4 "harsh outdoor conditions (including opencast mines And quarries) Electrical installations - Part 4. Device Requirements "(in English). This part is GB/T 9089.4-1992 "Electrical installations for outdoor harsh conditions means requirements" amendments. This section compared with the GB/T 9089.4-1992, there are some changes in the text, there is an increase of some clauses and amendments related to the main Differences are as follows. --- In accordance with the provisions of GB/T 1.1-2000, the original standard Chapter 1, "subject matter and scope" to "program", Chapter 2 "Reference standard" to "normative references", Chapter 3, "term" to "terms and definitions." --- The terms, definitions and GB 7251 series of standards in this section consistent translation, equipment for industry use. For example, the following terms have been modified. Activities formula → formula can migrate (mobile), movable → mobile (movable). Appendix A of this section is an informative annex. This Part replaces GB/T 9089.4-1992 "Electrical installations for outdoor harsh conditions device requirements." This part is proposed by the China Electrical Equipment Industrial Association. This part of the jurisdiction of the National Standardization Technical Committee on Low-voltage switchgear and control equipment. This section is drafted. Tianjin Electric Drive Design Institute, Beijing Coal Electric Co., Ltd., Chint Group Equipment Manufacturing Co., The company, Linhai City Yao-ming Power Equipment Co., Ltd., Beijing State Power Technology Co., Ltd. Kang. The main drafters of this section. Wangchun Juan, Wang Jiang Hua, Guzhi Lei, Xu Huayun, Yan Jing new, Luozheng Yang, Li Da. This part of the alternative criteria previously issued as follows. --- GB/T 9089.4-1992. GB/T 9089.4-2008/IEC 60621-4. 1981 Electrical installations for outdoor sites under heavy conditions Part 4. Installation Requirements

1 Scope

This section GB/T 9089 specifies the requirements for electrical apparatus --- facilities under harsh outdoor conditions, to ensure that people, animals and property security Full normal operation and equipment. This section applies to outdoor sites under heavy conditions (including opencast mines, quarries, storage yard and similar places) mining, stacker, primary processing machinery and Delivery systems and other electrical facilities. Range GB/T 9089.1-2008 apply to this section.

2 Normative references

The following documents contain provisions which, through reference to GB/T 9089 to the present, constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 9089.1-2008 Electrical installations outdoors under harsh conditions - Part 1. Scope and definitions (IEC 60621-1. 1987, IDT); Electrical installations - Part 2 9089.2-2008 under harsh outdoor conditions GB/T . General protection requirements (IEC 60621-2. 1987, MOD); General requirements for equipment and accessories for. Electrical installations Part 3 under GB/T 9089.3-2008 harsh outdoor conditions (IEC 60621-3. 1986, IDT); Electrical installations - Part 5 GB 9089.5-2008 outdoors under harsh conditions. Operational requirements (IEC 60621-5. 1987, IDT).

3 Terms and Definitions

Terms and definitions in this section, see GB/T 9089.1-2008. The first piece of mining, stacker and primary processing machinery requirements

4 Additional requirements for direct contact and indirect contact protection

4.1 parts mounting When installing the motor, when current limit switches and sockets, if sufficient lead in articulating surfaces frame and structural components between the electrical equipment When the electricity area, is not required for structural components of the device using a special protection connection. In this case only requires a connection with ordinary bolts and screws. These principles are also suitable for connecting power distribution cabinets and terminal boxes of various types of electrical equipment. Equipment for corrosive gas or severe vibration conditions, you should use a separate protective conductor of the motor, the current limit switches, etc. connection. 4.2 can migrate away from the console and mobile accessories For can migrate and mobile auxiliary equipment (such as welding equipment, curing transformers, etc.), when they are being monitored and neither the protective conductor When obvious visible, should potential connection between such auxiliary equipment and electrical equipment with visible conductors like. 4.3 IT system insulation monitor In IT systems, such as the built-in power supply with electrical insulation transformer coil, generator or battery power supply line without configuration GB/T 9089.4-2008/IEC 60621-4. 1981
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 9089.4-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 9089.4-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 9089.4-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 9089.4-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 9089.4-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 9089.4-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.