GB/T 9009-2011 English PDFUS$489.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 9009-2011: Formaldehyde solution for industrial use Status: Valid GB/T 9009: Historical versions
Basic dataStandard ID: GB/T 9009-2011 (GB/T9009-2011)Description (Translated English): Formaldehyde solution for industrial use Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G17 Classification of International Standard: 71.080.80 Word Count Estimation: 21,220 Date of Issue: 2011-12-30 Date of Implementation: 2012-06-01 Older Standard (superseded by this standard): GB/T 9009-1998 Quoted Standard: GB 190; GB/T 601; GB/T 603; GB/T 3049; GB/T 3143; GB/T 4472; GB/T 6678; GB/T 6680; GB/T 6682; GB/T 8170; GB/T 9722 Adopted Standard: ASTM D2378-2007, MOD Regulation (derived from): Announcement of Newly Approved National Standards No. 23 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the requirements for industrial use formaldehyde solution, test methods, inspection rules, marking, packaging, transportation, storage, and security. This standard applies to the legal system by the oxidation of methanol formaldehyde solution for industrial use. GB/T 9009-2011: Formaldehyde solution for industrial use---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Formaldehyde solution for industrial use ICS 71.080.80 G17 National Standards of People's Republic of China Replacing GB/T 9009-1998 Industrial formaldehyde solution Issued on. 2011-12-30 2012-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 9009-1998 "industrial formaldehyde solution," compared with the GB/T 9009-1998, the main technical differences are as follows. --- Level increased by 50%, 44% industrial grade formaldehyde solution (see Chapter 4, Chapter 3 of the 1998 edition). --- Canceled 37% First grade level specifications (see Chapter 4, Chapter 3 of the 1998 edition). --- Revised test methods Density (see 5.4, version 4.1, 1998). --- Revised test methods formaldehyde content (see 5.5, Appendix B, 1998 edition 4.2). --- Revised test methods methanol content (see 5.9, Appendix C, 1998 edition 4.6). This standard uses redrafted law revision by the United States Society for Testing and Materials standard ASTMD2378.2007 "Standard Specification 50% No grade formaldehyde polymerization inhibitor and 37% level, and not polymerization of formaldehyde. " This standard ASTMD2378.2007 compared with more structure Adjustments listed in Appendix A of this standard reg number and ASTM D2378.2007 reg control list numbered. This standard ASTMD2378. Differences technical reasons and 2007 are as follows. --- An increase of 44% industrial grade with formaldehyde (see 4.2), to meet the needs of the market. --- Indicators divided into superior products and quality products (see 4.2), which is based on the grading of industrial products related to the determination. --- Determination of the content of methanol by gas chromatography and a lookup table (see 5.9), in order to meet the analysis requirements of different grades of products. The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Standardization Technical Committee Chemistry Organic Chemicals Branch (SAC/TC63/SC2) centralized. This standard drafting unit. China Petrochemical Group of Sichuan Vinylon Works. Participated in the drafting of this standard. Guangzhou Pearl River Chemical Industry Group Co., Ltd. Guangzhou solvent factory, China Formaldehyde Industry Association, of Puyang City, Peng Xin Industry Co., Ltd., China National Petroleum Corporation Jilin Petrochemical Company fertilizer plant, Zhejiang Jin Ju Chemical Co., Ltd. and Hubei Yihua And Chemical Corporation. The main drafters of this standard. Yan Hong, Pu Li Jun, Li Bin, Li Zhai, Zhou Bing, Lujia Yun, ZENG Yan, Xi Huang Quan, such as Yan Dong, Zhang Xianbo, Xie Meihua. This standard replaces the standards previously issued as follows. --- GB/T 9009-1988, GB/T 9009-1998. Industrial formaldehyde solution1 ScopeThis standard specifies the requirements for industrial use formaldehyde solution, test methods, inspection rules, marking, packaging, transportation, storage, and security. The standard Suitable for methanol oxidation by the quasi-legal system of industrial formaldehyde solution. Molecular formula. CH2O Molecular Weight. 30.03 (according to 2007 international relative atomic mass)2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 190 packaging and marking of dangerous goods Preparation of GB/T 601 chemical reagent standard titration solution GB/T 603 chemical reagent test method Preparations of articles (GB/T 603-2002, ISO 6353-1 with. 1982, NEQ) General Method GB/T 3049 Industrial chemicals determination of iron content 1,10-phenanthroline spectrophotometry GB/T 3143 Determination of color liquid chemicals (Hazen unit --- platinum - cobalt color number) GB/T 4472 chemical product density, relative density measurement General GB/T 6678 General Principles for Sampling Chemical Products GB/T 6680 General rules for sampling liquid chemical products GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3696. 1987, MOD) GB/T 8170 repair value expressed about the rules and limit values \u200b\u200band judgment GB/T 9722 General chemical reagent gas chromatography3 Product CategoriesIndustrial formaldehyde solution in accordance with the content is divided into three sizes. 37% level, 44% and 50% of grade level.4 Requirements4.1 Appearance. transparent liquid without suspension. Low temperature allowed whitely clouded. 4.2 Industrial formaldehyde solution should meet the technical requirements in Table 1 below. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 9009-2011_English be delivered?Answer: Upon your order, we will start to translate GB/T 9009-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 9009-2011_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 9009-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 9009-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 9009-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |