GB/T 7717.17-2009: Acrylonitrile for industrial use -- Part 17: Determination of content of copper -- Graphite furnace atomic absorption spectrometer method
Status: Obsolete
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 7717.17-2009239 Add to Cart 3 days Acrylonitrile for industrial use -- Part 17: Determination of content of copper -- Graphite furnace atomic absorption spectrometer method Obsolete

Similar standards

GB/T 3729   GB/T 6818   GB/T 6820   GB/T 7717.16   GB/T 7717.12   GB/T 7717.15   

Basic data

Standard ID: GB/T 7717.17-2009 (GB/T7717.17-2009)
Description (Translated English): Acrylonitrile for industrial use -- Part 17: Determination of content of copper -- Graphite furnace atomic absorption spectrometer method
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: G17
Classification of International Standard: 71.080.30
Word Count Estimation: 6,657
Date of Issue: 2009-10-30
Date of Implementation: 2010-06-01
Quoted Standard: GB/T 602; GB/T 3723; GB/T 6680; GB/T 6682; GB/T 8170
Regulation (derived from): National Standard Approval Announcement 2009 No.12 (Total No.152)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the determination of acrylonitrile industrial copper by graphite furnace atomic absorption spectrometry content. This section applies to the determination of trace copper acrylonitrile. Measuring range (0. 010 ~ 1. 000) mg/kg. This section is not intended to illustrate its use of all safety issues. Users are responsible for taking appropriate safety and health practices to ensure compliance with the relevant national regulations.

GB/T 7717.17-2009: Acrylonitrile for industrial use -- Part 17: Determination of content of copper -- Graphite furnace atomic absorption spectrometer method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Acrylonitrile for industrial use.Part 17. Determination of content of copper.Graphite furnace atomic absorption spectrometer method ICS 71.080.30 G17 National Standards of People's Republic of China Acrylonitrile for industrial use Part 17. Determination of copper content Graphite Furnace Atomic Absorption Spectrometry Posted 2009-10-30 2010-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

GB/T 7717 "Acrylonitrile for industrial use" is divided into the following sections. --- Part 1. Specification; --- Part 5. Determination of acidity, pH and titration values; --- Part 8. Determination of total aldehyde content spectrophotometry; --- Part 9. Determination of total cyanide titration; --- Part 10. Determination of the peroxide content spectrophotometry; --- Part 11. Determination of iron and copper content spectrophotometry; --- Part 12. Determination of purity and impurity gas chromatography; --- Part 15. Determination hydroxyanisole content spectrophotometry; --- Part 16. Determination of iron content by graphite furnace atomic absorption spectrometry; --- Part 17. Determination of copper content - Graphite furnace atomic absorption spectrometry. This section GB/T 7717 Part 19. This part is proposed by the China Petroleum and Chemical Corporation. This part of the National Standardization Technical Committee Petrochemical Chemical Technical Committee (SAC/TC63/SC4) centralized. This section drafted by. China Sinopec Shanghai Petrochemical Company Limited, China Petroleum & Chemical Corporation Shanghai Petrochemical Institute. The main drafters of this section. to Hao Wei, Quling Di, Jiangcai Ying, Zhang Zhenghua, Wang Chuan, Chen Hongde, Chen Huili, Chen Huan. Acrylonitrile for industrial use Part 17. Determination of copper content Graphite Furnace Atomic Absorption Spectrometry

1 Scope

This section specifies the determination by graphite furnace atomic industry acrylonitrile content of copper absorption. This section applies to the determination of trace copper acrylonitrile, measurement range (0.010 ~ 1.000) mg/kg. This section is not intended to illustrate its use of all safety-related issues. The user's responsibility to take appropriate safety and health measures Facilities, to ensure compliance with the provisions of the relevant national regulations.

2 Normative references

The following documents contain provisions which, through reference to GB/T 7717 this section, constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. Preparation of standard solution of GB/T 602 Determination of impurities in chemical reagents GB/T 3723 Sampling of chemical products for industrial use General Safety (GB/T 3723-1999, idt ISO 3165. 1976) GB/T 6680 General rules for sampling liquid chemical products GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3696. 1987, MOD) GB/T 8170 repair value expressed about the rules and limit values and judgment

3 Method summary

Acrylonitrile sample to be tested and in accordance with 1.4 volume ratio of ethanol to dilute the sample backward, the sample of copper in the graphite tube Plains Protonated, absorbance was measured at 324.8nm wavelength. Quantified using a standard curve.

4 Reagents and materials

4.1 Carrier gas. high-purity argon, purity (volume fraction) of not less than 99.999%. 4.2 Copper standard solution. 0.1mg/mL, prepared according to GB/T 602. 4.3 Ethanol. GR level, the copper content is less than 5ng/mL. 4.4 Distilled water. water should conform to two GB/T 6682 regulations.

5 Instruments

5.1 Atomic absorption spectrometer. with graphite furnace and autosampler. 5.2 Copper hollow cathode lamp. Means electronic integrator or spectral data processing means 5.3 records. 5.4 general laboratory equipment.

6 Sampling

According to GB/T 3723 and GB/T 6680 the technical requirements to take samples.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 7717.17-2009_English be delivered?

Answer: Upon your order, we will start to translate GB/T 7717.17-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 7717.17-2009_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 7717.17-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.