Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 7717.10-2008 English PDF

US$229.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 7717.10-2008: Acrylonitrile for industrial use -- Part 10: Determination of content of peroxides -- Spectrophotometric method
Status: Valid

GB/T 7717.10: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 7717.10-2008229 Add to Cart 3 days Acrylonitrile for industrial use -- Part 10: Determination of content of peroxides -- Spectrophotometric method Valid
GB/T 7717.10-1994199 Add to Cart 2 days Acrylonitrile for industrial use-Determination of content of peroxides-Spectrophotometric method Obsolete
GB/T 7717.10-1987RFQ ASK 3 days Acrylonitrile--Determination of peroxides Obsolete

Similar standards

GB/T 3729   GB/T 6818   GB/T 6820   GB/T 7717.12   GB/T 7717.16   GB/T 7717.1   

Basic data

Standard ID: GB/T 7717.10-2008 (GB/T7717.10-2008)
Description (Translated English): Acrylonitrile for industrial use -- Part 10: Determination of content of peroxides -- Spectrophotometric method
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: G17
Classification of International Standard: 71.080.30
Word Count Estimation: 10,191
Date of Issue: 2008-06-19
Date of Implementation: 2009-02-01
Older Standard (superseded by this standard): GB/T 7717.10-1994
Quoted Standard: GB/T 601; GB/T 603; GB/T 3723; GB/T 6680; GB/T 6682; GB/T 8170
Adopted Standard: ASTM E1784-1997 (2002), MOD
Regulation (derived from): National Standard Approval Announcement 2008 No.10 (Total No.123)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the industrial use-Determination of peroxide content in spectrophotometry. This section applies to peroxide (hydrogen peroxide) content of 0. 05mg/kg ~ 1. 0mg/kg industrial acrylonitrile sample. This section is not intended to illustrate its use of all safety issues. Responsibility of the user to establish appropriate safety and health practices to ensure compliance with the relevant national regulations.

GB/T 7717.10-2008: Acrylonitrile for industrial use -- Part 10: Determination of content of peroxides -- Spectrophotometric method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Acrylonitrile for industrial use Part 10. Determination of content of peroxides Spectrophotometric method. ICS 71.080.30 G17 National Standards of People's Republic of China Replacing GB/T 7717.10-1994 Acrylonitrile for industrial use Determination of the peroxide content. Part 10 Posted 2008-06-19 2009-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

GB/T 7717 "Acrylonitrile for industrial use" is expected to be divided into the following sections. --- Part 1. Specification; --- Part 5. Determination of acidity, pH and titration values; --- Part 8. Determination of total aldehyde content spectrophotometry; --- Part 9. Determination of total cyanide titration; --- Part 10. Determination of the peroxide content spectrophotometry; --- Part 11. Determination of iron and copper content spectrophotometry; --- Part 12. Determination of purity and impurity gas chromatography; --- Part 15. Determination hydroxyanisole content spectrophotometry. This section GB/T Part of 107,717. The partial modification using ASTME1784.1997 (2002) "Standard Test Method for Determination of acrylonitrile in total peroxide content of" (English Version), this portion ASTME1784.1997 (2002) of the structural differences in Appendix A. This portion ASTME1784.1997 (2002) of the main differences are. --- Normative documents used in current national standards; --- Applicable concentration range was revised to 0.05mg/kg ~ 1.0mg/kg; --- In the preparation of peroxide-free acrylonitrile, remove the ion exchange resin; distillation of the caustic alkali concentration is reduced to 7% (Mass fraction), remove the water, increasing the anhydrous calcium chloride dehydration step; and clearly the conditions for preparation of activated alumina adsorption method; --- Adjust the color reaction order of addition of reagents; --- Shaking clearly defined time after potassium iodide was 3min, coloration time to 40min; --- Absorption cell specifications from 1cm adjusted 2cm; --- Change the calibration curve method of preparation of each concentration point; --- Increase the use of standard potassium permanganate titration solution of hydrogen peroxide stock solution calibration method; This Part replaces GB/T 7717.10-1994 "industrial use - Determination of acrylonitrile content of peroxides spectrophotometry." This portion of the GB/T 7717.10-1994 main changes are as follows. --- Applicable concentration range was revised to 0.05mg/kg ~ 1.0mg/kg; --- Distillation of the caustic alkali concentration to 7% (mass fraction), anhydrous calcium chloride to reduce the drying time of 4h; increase Using activated alumina prepared without peroxide acrylonitrile; --- Shaking time after potassium iodide was added to 3min; --- Absorption cell specifications from 1cm adjusted 2cm; --- Changing the preparation method and the calibration curve standard solution prepared in the way of each concentration point; --- Increase the use of sodium thiosulfate standard titration solution of hydrogen peroxide stock solution calibration method; Appendix A of this section is an informative annex. This part is proposed by the China Petroleum and Chemical Corporation. This part of the National Standardization Technical Committee Petrochemical Chemical Technical Committee (SAC/TC63/SC4) centralized. This section is drafted. Shanghai Research Institute of Petrochemical. The main drafters of this section. Gao Qiong, Li Jia Wei, Wang Chuan. This part of the standard replaces the previous editions are. GB 7717.10-1987, GB/T 7717.10-1994. Acrylonitrile for industrial use Determination of the peroxide content. Part 10 Spectrophotometry

1 Scope

1.1 part specifies the determination Acrylonitrile for industrial use spectrophotometric peroxide content. This section applies to a peroxide (hydrogen peroxide) content of 0.05mg/kg ~ 1.0mg/kg industrial acrylonitrile sample. 1.2 section is not intended to illustrate its use of all safety-related issues. Responsibility of the user to establish appropriate safety and health measures Facilities, to ensure compliance with the provisions of the relevant national regulations.

2 Normative references

The following documents contain provisions by GB/T 7717 reference in this part of the provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. Preparation of GB/T 601 chemical reagent standard titration solution GB/T 603 chemical reagent in test methods - Preparations with GB/T 3723 Sampling of chemical products for industrial use General Safety (GB/T 3723-1999, idt ISO 3165. 1976) GB/T 6680 General rules for sampling liquid chemical products GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3696. 1987, MOD) GB/T 8170 numerical rounding rules

3 Method summary

Under the action of acetic anhydride, the peroxide sample with potassium iodide, to form a yellow triiodide ions (I3-). Using a spectrophotometer to Determination of absorbance at a wavelength of 365nm of the solution, according to the standard solution of hydrogen peroxide calibration curve sample Richard peroxide (in H2O2 meter) content.

4 Instrument

4.1 Spectrophotometer. Accuracy ± 0.001A, configuration 2cm quartz absorption cell; 4.2 Electronic balance. a sense of the amount of 0.1mg; 4.3 Timer; 4.4 pH meter. accuracy 0.1pH; 4.5 stoppered conical flask. 100mL; 4.6 iodine bottle. 250mL; 4.7 Buret. 25mL, brown; 4.8 flask. 50mL, 100mL and 500mL brown; 4.9 Graduated pipettes. 1mL; 5mL; 4.10 Single-marking pipette. 0.5mL, 2mL, 5mL and 25mL; 4.11 separatory funnel. 1000mL;
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 7717.10-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 7717.10-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 7717.10-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 7717.10-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 7717.10-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 7717.10-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.