GB/T 7341.3-2024 English PDFUS$314.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 7341.3-2024: Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration Status: Valid GB/T 7341.3: Historical versions
Basic dataStandard ID: GB/T 7341.3-2024 (GB/T7341.3-2024)Description (Translated English): Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: A59 Word Count Estimation: 16,163 Date of Issue: 2024-08-23 Date of Implementation: 2024-08-23 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 7341.3-2024: Electroacoustics - Audiometric equipment - Part 3: Test signals of short duration---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Electroacoustics - Audiometric equipment - Part 3.Test signals of short duration Electroacoustic audiometry equipment Part 3.Short-duration test signals Electroacoustics-Audiometric equipment- Part 3.Test signals of short duration (IEC 60645-3.2020, IDT) ICS 17.140.50 CCS A59 National Standard of the People's Republic of China Replaces GB/T 7341.3-1998 Released on 2024-08-23 2024-08-23 implementation State Administration for Market Regulation The National Standardization Administration issued Table of ContentsPreface ... Ⅲ Introduction Ⅳ 1 Scope ... 1 2 Normative references ... 1 3 Terms and Definitions 2 4 Reference Signal ... 5 4.1 Overview ... 5 4.2 Reference short beeps 5 4.3 Reference Tone Burst ... 5 4.4 Reference Broadband Warbling Tone 6 4.5 Reference Octave Band Warbling Tone 6 5 Calibration and measurement of short-term signals 6 References ... 8 Figure 1 Schematic diagram of electrical reference short sound ... 2 Figure 2 Schematic diagram of the peak-to-peak equivalent signal level measurement method ... 2 Figure 3 Transient characteristics of electrical reference short pure tone ... 3 Figure 4 Time domain diagram of electrical reference short sound ... 5 Figure 5 Time domain characteristics of electrical reference broadband warbling tone ... 6ForewordThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting is required. This document is Part 3 of GB/T 7341.GB/T 7341 has published the following parts. Electroacoustic audiometric equipment Part 1.Pure tone audiometer (GB/T 7341.1); Audiometer Part 2.Speech Audiometry Equipment (GB/T 7341.2); - Electroacoustic audiometric equipment Part 3.Short-term test signals (GB/T 7341.3); Audiometer Part 4.Equipment for extended high-frequency audiometry (GB/T 7341.4); Electroacoustic audiometry equipment Part 5.Instruments for measuring ear acoustic impedance/admittance (GB/T 7341.5). - This document replaces GB/T 7341.3-1998 "Audiometer Part 3.Short-duration auditory test signals for audiometry and neuro-otology" Compared with GB/T 7341.3-1998, in addition to structural adjustments and editorial changes, the main technical changes are as follows. Changed the "short-term signal", "short sound", "short pure tone", "dense wave signal", "sparse wave signal", "short sound stimulation signal initial The terms and definitions of “wave”, “duration of the initial wave of the short stimulus signal” and “peak-to-peak equivalent signal level” (see 3.1, 3.2, 3.3, 3.9, 3.10, 3.12, 3.13 and 3.16 of the.1998 edition and 3.1, 3.5, 3.2, 3.8, 3.9, 3.6, 3.7 and 3.10); Added "Instantaneous frequency", "Warp", "Upper warbling", "Broadband warbling", "Octave warbling", "Alternate polarity signal" and The term and definition of “root mean square signal level” (see 3.4, 3.5, 3.6, 3.7, 3.8, 3.11, 3.17); Changed some contents of "Reference Signal" (see Chapter 5, Chapter 4 of the.1998 edition); - Added "Schematic diagram of electrical reference short tone", "Time domain diagram of electrical reference short tone" and "Time domain characteristics of electrical reference broadband warbling tone" Schematic diagram of (see Figures 1, 4 and 5); "Using hearing level to determine signal level" (see Chapter 6 of the.1998 edition) has been deleted. - This document is equivalent to IEC 60645﹘3.2020 "Electroacoustic audiometric equipment Part 3.Short-term test signals". Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document is proposed and coordinated by the National Electroacoustics Standardization Technical Committee (SAC/TC 23). This document was drafted by. The Sixth Medical Center of PLA General Hospital, China Institute of Metrology, Institute of Acoustics, Chinese Academy of Sciences, The Third Research Institute of China Electronics Technology Group Corporation and Shenzhen Tiansuo Metrology and Testing Co., Ltd. The main drafters of this document are. Ji Fei, Zhong Bo, Chen Aiting, Yang Shiming, Yu Liming, Wu Qian, Han Lumeng, Xu Huan, Li Xiaodong, Wu Xin, Cui Jian, Zhang Guoqing. The previous versions of this document and the documents it replaces are as follows. First published in 1987 as GB/T 7341-1987, first revised in.1998; - This is the second revision. -IntroductionWith the development of the field of hearing testing for the purpose of hearing diagnosis, hearing protection and rehabilitation, the application scope of audiometric equipment is expanding. Furthermore, audiometric equipment is essentially a collection of functional units that can be specified separately. The performance of audiometric equipment using these functional units. GB/T 7341 "Electroacoustics - Audiometric Equipment" is intended to consist of seven parts. Part 1.Pure Tone Audiometers. The purpose is to specify general requirements for audiometers and test methods using psychoacoustics. Specific requirements for pure tone audiometers designed by comparison with standard reference hearing threshold levels. Part 2.Speech Audiometry Equipment. It is intended to test the hearing of a given subject using speech as a test stimulus. The calibration method can give basically the same results. The output level produced by the earphone and bone vibrator is given with its specifications and calibration. method. Part 3.Short-term test signals. The purpose is to specify the use of electrical waveforms to describe short-term audiometric reference signals and short-term test signals. The physical characteristics of the signal and the corresponding measurement methods are used to ensure that short-term signals are specified and measured in the same way and that the specified A certain method is used to calibrate equipment using this signal. Part 4.Equipment for extended high-frequency audiometry. The purpose is to ensure that different types of equipment can perform extended high-frequency audiometry on a given human ear. When the frequency was measured, it gave basically the same results. Part 5.Instruments for measuring acoustic impedance/admittance of the ear. The purpose is to specify the characteristics of three types of instruments for measuring acoustic impedance/admittance of the ear. The facilities and conditions provided for these instruments, as well as the test methods used for acceptance testing and to guide routine calibration, ensure compliance with this document. The consistency of various instruments under comparable test conditions. Part 6.Instruments for measuring otoacoustic emissions. The purpose is to ensure that different types of instruments are used to measure the otoacoustic emissions of the human external auditory canal caused by pulsed probe tones. or pure tone evoked otoacoustic emissions are designed to measure the consistency of the results under similar test conditions. Part 7.Instruments for measuring auditory brainstem responses. The purpose is to ensure that different types of instruments are designed for measuring auditory brainstem responses caused by short-term acoustic and/or vibration The results of the test under similar test conditions were obtained by using an instrument that induces auditory evoked potentials in the inner ear, auditory nerve, and brainstem by using dynamic stimulation. Consistency. This document includes requirements for reference signals and other short-duration test signals. Common tests using these signals include recording auditory brain This document describes reference signals to provide baseline values for calibration and to be used when there is no clear reason to use an alternative. This document also describes the measurement methods for short-term acoustic and vibration signals. Electroacoustic audiometry equipment Part 3.Short-duration test signals1 ScopeThis document describes the method of describing the physical characteristics of short-duration audiometric reference signals and short-duration test signals using electrical waveforms and the corresponding measurements method. This document ensures that short-duration signals are specified and measured in the same way and that equipment using such signals is calibrated using specified methods. allow. This document does not describe the use of short-duration test signals.2 Normative referencesThe contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies. in this document. ISO 389﹘6 Acoustic calibration of audiometric equipment - Reference zero level - Part 6.Reference hearing thresholds for short-duration test signals tics-Reference zero for the calibration of audiometric equipment-Part 6.Reference threshold of hear﹘ ing for test signals of short duration) Note. GB/T 4854.6-2014 Reference zero level for acoustic calibration of audiometric equipment Part 6.Reference hearing threshold for short-duration test signals (ISO 389﹘6.2007, IDT) IEC 60318﹘1 Electroacoustics Head simulators and ear simulators Part 1.Ear simulators for measuring supra-aural and circumaural headphones (Electroacoustics-Simulators of human head and ear-Part 1.Ear simulator for the measurement of supra-aural and circumaural earphones) Note. GB/T 25498.1-2010 Electroacoustics Head simulators and ear simulators Part 1.Ear simulators for calibrating supra-aural headphones (IEC 60318﹘1.1998, IDT) IEC 60318﹘3 Electroacoustics Head and Ear Simulators Part 3.Acoustic Couplers for Calibration of Supra-Aural Audiometry Headphones (Electroacoustics-Simulators of human head and ear-Part 3.Acoustic coupler for the calibration of supra﹘aural earphones used in audiometry) Note. GB/T 25498.3-2010 Electroacoustics Head and Ear Simulators Part 3.Acoustic Couplers for Calibration of Press-On Audiometry Headphones (IEC 60318﹘3.1998, IDT) IEC 60318﹘4 Electroacoustic head simulator and ear simulator Part 4.Occluded ear simulator for measuring insert earphones (Elec﹘ troacoustics-Simulators of human head and ear-Part 4.Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts) IEC 60318﹘5 Electroacoustic head simulator and ear simulator Part 5.Measurement of hearing aids and insertion coupling to the human ear Electroacoustics-Simulators of human head and ear-Part 5.2 cm3 coupler for the measurement of hearing aids and earphones coupled to the ear by means of ear inserts) Note. GB/T 25498.5-2017 Electroacoustic head simulator and ear simulator Part 5.Measurement of hearing aids and hearing aids coupled to the human ear by insertion 2 cm3 coupler for headphones (IEC 60318﹘5.2006, IDT) IEC 60318﹘6 Electroacoustic head simulators and ear simulators Part 6.Force couplers for bone vibrator measurements (Elec﹘ troacoustics-Simulators of human head and ear-Part 6.Mechanical coupler for the measurement of Bone vibrators ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 7341.3-2024_English be delivered?Answer: Upon your order, we will start to translate GB/T 7341.3-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 7341.3-2024_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 7341.3-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 7341.3-2024?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 7341.3-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |