GB/T 7106-2019 English PDFUS$599.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 7106-2019: Test methods of air permeability, water tightness, wind load resistance performance for building external windows and doors Status: Valid GB/T 7106: Historical versions
Basic dataStandard ID: GB/T 7106-2019 (GB/T7106-2019)Description (Translated English): Test methods of air permeability, water tightness, wind load resistance performance for building external windows and doors Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: P32 Classification of International Standard: 91.060.50 Word Count Estimation: 30,370 Date of Issue: 2019-12-10 Date of Implementation: 2020-11-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 7106-2019: Test methods of air permeability, water tightness, wind load resistance performance for building external windows and doors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. (Testing methods for airtightness, watertightness, and wind pressure resistance of external doors and windows of buildings) ICS 91.060.50 P32 National Standards of People's Republic of China Replaces GB/T 7106-2008 Airtight, watertight, and wind pressure resistance of the building's exterior windows and doors Performance testing method Testmethodsofairpermeability, watertightness, windloadresistance 2019-12-20 release 2020-11-01 implementation State Administration of Market Supervision Published by the National Standardization Management Committee ContentsForeword I 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Detection principle 3 5 Detection device 3 6 Test preparation 5 7 Airtight performance test 6 8 Watertight performance test 9 9 Wind pressure resistance test 11 10 Repeated airtight performance test 17 11 Repeated watertight performance test 17 12 Test report 17 Appendix A (Normative Appendix) Calibration Method for Air Flow Measurement Device 19 Appendix B (Normative Appendix) Calibration Method of Water Sprinkler 21 Appendix C (informative) Linear regression calculation method 23 Appendix D (informative) Sample test report 26ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB/T 7106-2008 "Classification and Test Method for Wind Pressure Resistance of Building Exterior Windows", which is in line with GB/T 7106-2008 The main technical changes are as follows. --- Deleted the definition of severe leakage (see 3.4.1 of the.2008 version); --- Added definition of analog static pressure box method (see 3.8); --- Deleted the classification of air tightness, water tightness and wind pressure resistance (see Chapter 4 of the.2008 edition); --- Adjusted the schematic diagram of the detection device (see 5.1, 5.1 of the.2008 version); --- Modified the detection order of grading testing and engineering testing (see 6.5.1 and 6.5.2, 6.4 of the.2008 version); --- Airtight performance is tested by air collection box method, and the pressure detection sequence of the rating test of airtight performance is adjusted (see 7.1.1, 2008 version 7.1); --- Increased engineering testing and judgment methods for airtight performance (see 7.1.2 and 7.4.2); --- Adjust the water leakage of the engineering test for watertight performance (see 8.3.2, 8.3 of the.2008 version); --- Modified the judgment method of watertight performance test results (see 8.5,.2008 version 8.5); --- Increased wind load resistance value test and wind load design value test (see 9.2.6 and 9.2.7); --- Add repeated airtight and watertight performance testing chapters (see Chapters 10 and 11); --- Added linear regression calculation method (see Appendix C). This standard was proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China. This standard is under the jurisdiction of the National Technical Committee for Standardization of Curtain Wall Doors and Windows (SAC/TC448). This standard was drafted. China Academy of Building Research Co., Ltd., Guangdong Building Research Institute Group Co., Ltd., Shandong Provincial Building Research Institute Co., Ltd., Henan Provincial Building Research Institute Co., Ltd., Fujian Provincial Building Research Institute Co., Ltd., Zhejiang Construction Science Design and Research Institute Co., Ltd., Jiangsu Construction Engineering Quality Inspection Center Co., Ltd., Shanghai Academy of Building Science (Group) Co., Ltd., China Building Materials Inspection and Certification Group Co., Ltd., China Construction Metal Structure Association, Xinjiang Academy of Building Research (Limited liability company), Guangdong Jianmei Aluminum Profile Factory (Group) Co., Ltd., Zhejiang Ruiming Energy Saving Technology Co., Ltd., Guangzhou Baiyunhua Industrial Co., Ltd., Guangdong Baker Luo Curtain Wall Door and Window System Co., Ltd., Sanhe Heping Aluminum Factory Co., Ltd., Hebei China Glass New Material Co., Ltd. Company, Guangdong Shijida Decoration Engineering Co., Ltd., Guangdong Jianlang Hardware Products Co., Ltd., Hegang Engineering Quality Inspection Center, Weike Kai (China) Investment Co., Ltd., Hebei Aorun Shunda Window Industry Co., Ltd., Harbin Medium and Large Material Technology Co., Ltd., Tianjin Housing Branch Institute of Technology, Shenyang Ziwei Electromechanical Equipment Co., Ltd. The main drafters of this standard. Wang Hongtao, Qiu Ming, Liu Huitao, Zhang Shixiang, Tian Huaqiang, Yi Qiang, Li Guangxu, Fan Yi, Jiang Meiqin, Xu Qin, Wan Chenglong, Yan Qiang, Dong Renwen, Yi Xubiao, Chen Xiangdong, Yu Zhilong, Dong Chengming, Zhang Guanqi, Lin Zhaoyi, Yang Wenjie, Luo Wenzhong, Yang Jianxing, Han Kun, Xu Hongfeng, Shi Wei, Jiao Changlong, Zong Xiaodan, Ma Biao, Wang Junyang, Sun Meifeng, Wan Jun. The previous versions of the standards replaced by this standard are. --- GB/T 7106-1986, GB/T 7106-2002, GB/T 7106-2008; --- GB/T 7107-1986, GB/T 7107-2002; --- GB/T 7108-1986, GB/T 7108-2002; --- GB/T 13685-1992; --- GB/T 13686-1992. Airtight, watertight, and wind pressure resistance of the building's exterior windows and doors Performance testing method1 ScopeThis standard specifies the terms and definitions of air-tight, water-tight, and wind-resistant performance of external doors and windows of buildings, testing principles, testing devices, testing preparation, Airtight performance test, watertight performance test, wind pressure resistance test, repeated airtight performance test, repeated watertight performance test and test report. This standard applies to the testing of airtight, watertight, and wind pressure resistance performance of building exterior doors and windows. Detection objects are limited to doors and windows or Framed doors and windows do not involve joints between them and other structures such as building walls.2 Normative referencesThe following documents are essential for the application of this document. For dated references, only the dated version applies to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 5823 terminology for building doors and windows GB/T 31433 General technical requirements for building curtain walls, doors and windows GB 50009 Load Code for Building Structures GB 50178 Standard for Building Climate Zoning3 terms and definitionsGB/T 5823 and the following terms and definitions apply to this document. 3.1 External windows and doors A collective term for the exterior doors and windows of a building. 3.2 Pressuredifference The difference between the absolute pressure of air on the exterior and interior surfaces of doors and windows. Note. When the pressure on the outdoor surface is higher than the pressure on the indoor surface, the pressure difference is positive; otherwise it is negative. 3.3 Airpermeabilityperformance The ability of the outer doors and windows to prevent air penetration when the openable part is in a normal locked state. 3.3.1 Standard condition Test with air temperature of 293K (20 ° C), atmospheric pressure of 101.3kPa (760mmHg), and air density of 1.202kg/m3 condition. 3.3.2 Air permeability volumeofairleakage The amount of air passing through the test unit per unit time. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 7106-2019_English be delivered?Answer: Upon your order, we will start to translate GB/T 7106-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 7106-2019_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 7106-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 7106-2019?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 7106-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |