GB/T 7095.4-2008 English PDFUS$134.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 7095.4-2008: Enamelled rectangular copper winding wires -- Part 4: Polyesterimide enamelled rectangular copper wire, class 180 Status: Valid GB/T 7095.4: Historical versions
Basic dataStandard ID: GB/T 7095.4-2008 (GB/T7095.4-2008)Description (Translated English): Enamelled rectangular copper winding wires -- Part 4: Polyesterimide enamelled rectangular copper wire, class 180 Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K12 Classification of International Standard: 29.060.10 Word Count Estimation: 7,773 Date of Issue: 2008-06-13 Date of Implementation: 2009-03-01 Older Standard (superseded by this standard): GB/T 7095.4-1995 Quoted Standard: GB/T 7095.1-2008 Adopted Standard: IEC 60317-28-1990, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 10 of 2008 (total 123) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies 180 polyester -imide resin-based single flat enamelled copper winding wire coating requirements. If they can retain the original chemical properties of the resin and meets all the requirements for enameled wire, the resin can be modified. GB/T 7095.4-2008: Enamelled rectangular copper winding wires -- Part 4: Polyesterimide enamelled rectangular copper wire, class 180---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Enamelled rectangular copper winding wires.Part 4. Polyesterimide enamelled rectangular copper wire, class 180 ICS 29.060.10 K12 National Standards of People's Republic of China GB/T 7095.4-2008/IEC 60317-28..1990 Replacing GB/T 7095.4-1995 Enameled copper flat winding wire Part 4. Polyester imine enamelled copper flat wire (IEC 60317-28..1990, Specificationsforpartulaulartsypesofwindingwires- Part 28. Polyesterimideenameledrectangularcopperwire, class180, IDT) 2008-06-13 released 2009-03-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Definitions, test methods General and appearance 1 4 size 1 5 resistance 1 6 elongation 1 7 bounce angle 2 8 Flexibility and adhesion 2 9 thermal shock 2 10 softening breakdown 2 11 scratch 2 12 solvent resistance 2 13 breakdown voltage 2 14 Insulation continuity 2 15 temperature index 2 16 resistant cryogen 2 17 weldability 2 18 Thermal bonding or solvent bonding 2 19 Dielectric loss factor 2 20 transformer oil resistance 2 23 pinhole test 3 30 packaging 3 GB/T 7095.4-2008/IEC 60317-28..1990 ForewordGB/T 7095-2008 "enameled copper flat winding wire" is divided into seven parts. --- Part 1. General provisions; --- Part 2. 120 acetal enamelled copper flat wire; --- Part 3. 155 polyester enamelled copper flat wire; --- Part 4. 180 polyester imide enamelled copper flat wire; --- Part 5. Class 240 aromatic polyimide enamelled copper flat wire; --- Part 6..200 polyester or polyester imide/polyamideimide enamelled copper flat wire; --- Part 7. 130 polyester enameled copper flat wire. This section GB/T 7095 Part 4. This section identical with IEC 60317-28..1990 "Special winding wire standard Part 28. 180 polyester imide enamelled copper flat wire" Version 1.0 (English version) as well as No. 1 (1997) and No. 2 (2007). For ease of use, this section made the following editorial changes. --- Removed the foreword and introduction of international standards; --- with decimal point '. 'Instead of comma as a decimal point', '; --- Correct editorial errors in IEC 60317-28..1990, supplemented by Chapter 23, "Pinhole Testing." This section from the date of implementation instead of GB/T 7095.4-1995. This section compared with GB/T 7095.4-1995, the main changes are as follows. --- Rewrite GB/T 7095.4-1995 according to the structure and content of IEC 60317-28..1990; --- Nominal size range of the conductor and heat resistance are listed in Chapter 1, "Range"; --- Added Chapter 3 "Definitions, Test Methods General and Appearance." This part is proposed by China Electrical Equipment Industry Association. This part of the wire and cable standardization Technical Committee (SAC/TC213) centralized. This section is drafted. Shanghai Electric Cable Research Institute, Shun Electric Co., Ltd. Panyu Branch, Shanghai Shen Mao Electromagnetic Wire Co., Ltd., Jiang Su Xunda Electromagnetic Wire Co., Ltd., Baoding Tianwei Power Wire Co., Ltd., Shanghai Yangxing Copper Co., Ltd., Shenyang Hongyuan Limited magnet wire the company. The main drafters of this section. Chen Huimin, Wang Juan, Song An, Zhou Zhiyun, Kang Jing, Liu Shunrong, Yang Xuqing. This part of the standard replaces the previous editions are. --- GB/T 7095.4-1986, GB/T 7095.4-1995. GB/T 7095.4-2008/IEC 60317-28..1990 Enameled copper flat winding wire Part 4. Polyester imine enamelled copper flat wire1 ScopeGB/T 7095 provisions of this part of 180 to polyesterimide resin-based single-coated enameled copper flat winding wire requirements. If you can The resin can be modified by retaining the chemical properties of the original resin and meeting all the requirements of the enameled wire. Note. The modified resin is a chemically-modified resin or resin containing one or more additives to enhance its properties or properties. Class 180 represents the thermal class, which requires a minimum temperature index of 180 and a thermal shock temperature of at least.200 ° C. The Celsius temperature that corresponds to the temperature index is not the recommended enamel temperature because it depends on the type of equipment being used Many factors within. This section applies to the conductor nominal size range. --- Wide side size. the smallest 2.00mm, the largest 16.00mm; --- Narrow side size. the smallest 0.80mm, the largest 5.60mm. This section includes the first and second grade paint film enameled copper flat wire, and applies to all the specifications of the conductor range. The combination of wide-brimmed and narrow-brimmed dimensions, and wide/narrow ratio see GB/T 7095.1-2008.2 Normative referencesThe following documents contain provisions which, through reference in this part of GB/T 7095, become the provisions of this section. Any reference to the date of the citation All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to be reached under this section The parties to the agreement examine whether the latest versions of these documents are available. For undated references, the latest version applies to this book section. GB/T 7095.1-2008 enameled copper flat winding wire - Part 1. General provisions (IEC 60317-0-2..2005, IDT) 3 Definitions, test methods General and appearance 3.1 Definitions and test methods General Definitions and test methods See GB/T 7095.1-2008 in Chapter 3. If GB/T 7095.1-2008 contradicts with this part, this part shall prevail. 3.2 appearance See Chapter 3 of GB/T 7095.1-2008.4 sizeSee Chapter 4 of GB/T 7095.1-2008.5 resistanceSee GB/T 7095.1-2008 Chapter 5.6 ElongationSee GB/T 7095.1-2008 Chapter 6. GB/T 7095.4-2008/IEC 60317-28..1990 ...... |