Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 7025.1-2023 English PDF

US$659.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 7025.1-2023: Lifts - Main specifications and the dimensions, arrangements for its cars, wells and machine rooms - Part 1: Lifts of classes I, II, III, Ⅵ
Status: Valid

GB/T 7025.1: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 7025.1-2023659 Add to Cart 6 days Lifts - Main specifications and the dimensions, arrangements for its cars, wells and machine rooms - Part 1: Lifts of classes I, II, III, Ⅵ Valid
GB/T 7025.1-2008999 Add to Cart 5 days Lifts -- Main specification and the dimensions, arrangements for its cars, wells and machine rooms -- Part 1: lifts of classes Ⅰ, Ⅱ, Ⅲ, Ⅵ Obsolete
GB/T 7025.1-1997519 Add to Cart 4 days Lifts--Main specifications and the dimensions, arrangements for its cars, wells and machine rooms. Part 1: Lifts of classesI, II, Ⅲ Obsolete
GB/T 7025-1986RFQ ASK 3 days Lifts--Main specifications and the dimensions, arrangements for its cars, wells and machine rooms Obsolete

Similar standards

GB/T 10059   GB/T 10060   GB/T 10058   GB/T 7024   GB/T 7024   GB/T 7025.2   

Basic data

Standard ID: GB/T 7025.1-2023 (GB/T7025.1-2023)
Description (Translated English): Lifts - Main specifications and the dimensions, arrangements for its cars, wells and machine rooms - Part 1: Lifts of classes I, II, III, ��
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: Q78
Classification of International Standard: 91.140.90
Word Count Estimation: 32,321
Date of Issue: 2023-05-23
Date of Implementation: 2023-05-23
Older Standard (superseded by this standard): GB/T 7025.1-2008
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 7025.1-2023: Lifts - Main specifications and the dimensions, arrangements for its cars, wells and machine rooms - Part 1: Lifts of classes I, II, III, Ⅵ


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 91:140:90 CCSQ78 National Standards of People's Republic of China Replace GB/T 7025:1-2008 Elevator main parameters and car, shaft, The type and size of the computer room Part 1: Elevators of categories Ⅰ, Ⅱ, Ⅲ and Ⅵ cars, wels and machine rooms-Part 1: Lifts of classes Ⅰ, Ⅱ, Ⅲ, Ⅵ Part 30:ClassⅠ,Ⅱ,ⅢandⅥliftsinstalation, MOD) Released on 2023-05-23 Implemented on 2023-05-23 State Administration for Market Regulation Released by the National Standardization Management Committee

table of contents

Preface III Introduction V 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 3:1 General terms and definitions 1 3:2 Elevator Type 2 3:3 Terminology related to size 2 3:4 Terms related to other characteristics 5 4 Elevator characteristic parameters 5 4:1 Priority number system 5 4:2 Rated load capacity 5 4:3 Rated speed 5 4:4 Selection of Elevator Type 6 5 size 6 5:1 Dimensions inside the car 6 5:2 Internal dimensions of the hoistway 7 5:3 Dimensions of the waiting hall 10 5:4 Machine Room Dimensions of Electric Drive Elevator 10 5:5 Machine room size of hydraulic elevator 12 5:6 Computer room layout (if applicable) 12 Reference 27

foreword

This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules for Standardization Documents" drafting: This document is the first part of GB/T 7025 "Elevator Main Parameters and Types and Dimensions of Cars, Shafts and Machine Rooms": GB/T 7025 has The following parts have been published: ---Part 1: Class I, II, III, VI elevators; --- Part 2: Class IV elevators; --- Part 3: Class V elevators: This document replaces GB/T 7025:1-2008 "Main Parameters of Elevators and Types and Dimensions of Cars, Shafts and Machine Rooms - Part 1: Ⅰ, Ⅱ, Compared with GB/T 7025:1-2008, except for structural adjustment and editorial changes, the main technical changes of Class III and VI Elevators are as follows: a) Delete the definition of "cargo elevator" (see 2:1:5 of the:2008 edition); b) Added the definitions of "machine room-less elevator" and "elevator", terms related to size and terms related to other characteristics (see 3:1:5, 3:1:6, 3:3 and 3:4); c) Deleted "Description of Symbols" and Table 1 (see 2:3 and Table 1 of the:2008 edition); d) Changed the relevant instructions that the buyer and the construction unit must meet the hoistway dimensions specified by the elevator manufacturer (see 5:2:1:1, 4:2:1 of the:2008 edition); e) The description of the situation not considered in the waiting hall has been added (see 5:3:1); f) Deleted the minimum depth requirement of 1800mm for the elevator lobby suitable for disabled persons (see 4:3:2 of the:2008 edition); g) Increased the size of the waiting hall to consider the turning space of the wheelchair (see 5:3:2); h) The relevant requirements for the size of the machine room in the planning stage are added, and the buyer and construction unit must meet the requirements of the elevator manufacturer Relevant instructions on the size of the computer room (see 5:4:1 and 5:5:1); i) Changed the scope of application of residential elevators and general-purpose elevators and the size requirements for people with disabilities, and added The specifications of 1000kg and 1275kg and the width of elevator shaft without machine room are explained (see Figure 5, Figure 5 of the:2008 edition); j) Changed the size requirements for general-purpose elevators suitable for use by disabled persons (see Figure 6, Figure 6 of the:2008 edition); k) Added the dimensions of shaft depth, shaft width, entrance width, car width and car depth when the counterweight of a general-purpose elevator is placed on its side requirements (see Figure 7): This document is modified to adopt ISO 8100-30:2019 "Elevators for the carriage of people and goods - Part 30: Elevators of categories I, II, III, and VI": The technical differences between this document and ISO 8100-30:2019 and their reasons are as follows: --- In 3:1:6, the definition of elevator was changed to meet the actual situation; --- In 3:1:8, the definition of the well was changed to conform to the actual situation; --- In 4:2, 320kg, 400kg, 600kg, 750kg, 825kg, 900kg, 1050kg, 1150kg are added, which are optional The rated load capacity is suitable for the national conditions of our country; --- In 4:3, 0:5m/s is added as an optional rated speed to suit my country's national conditions; --- In 5:1:2, delete the requirement of "see Figure 10~Figure 13 for specific market demand" to suit my country's national conditions; --- In Table 1, the vertical allowable deviation of the shaft size has been changed to suit my country's national conditions; --- In 5:2:1:2:2, the requirements for the allowable deviation K value of the hoistway are added, and Note 1 and Note 2 are deleted to suit my country national conditions; --- In 5:3:2, the requirements for the waiting hall have been changed to suit my country's national conditions; --- In Table 2, some of the rated load capacity and rated speed and the corresponding size requirements have been added, and the rated speed has been changed 2:5m/s rated load capacity 1000/1050/1150/1275kg top floor height, to suit my country's national conditions; --- Changed the titles of Figure 10, Figure 11, Figure 12 and Figure 13, and deleted the dimensional drawing of the counterweight lateral position in Figure 11 to suit my country's national conditions: The following editorial changes have been made to this document: --- Deleted the note in Chapter 1 of ISO 8100-30:2019; --- Deleted the example of 3:2:4 in ISO 8100-30:2019; --- In 3:3:12, add Note 2; --- In 4:1, the expression of the priority number system was modified to be consistent with GB/T 321-2005; ---In 5:1:1, Note 3 of Figure 5, Note 3 of Figure 6 and Note 3 of Figure 7, change "graphic symbols of ISO 7000-0100" to graphic symbols Number" "; --- In 5:4:3:2:3, the calculation formula for the minimum width of the machine room is corrected; --- In Figure 5, note 4 has been changed, and the description that the width of the hoistway is increased by 100mm in the case of machine room is added; --- In Figure 7, add Note 2; --- In 1275kg in Figure 9, change footnote "a" to footnote "d", and add explanation of footnote "d"; --- Deleted the content of "this type of elevator is used in Germany and Israel" in Note 5 in Figure 9 of ISO 8100-30:2019: This document is proposed and managed by the National Elevator Standardization Technical Committee (SAC/TC196): This document is drafted by: Xizi Elevator Technology Co:, Ltd:, Hangzhou Youmai Technology Co:, Ltd:, Shanghai Special Equipment Supervision and Inspection Technology Research Institute, China Academy of Building Research Co:, Ltd: Building Mechanization Research Branch, Schindler (China) Elevator Co:, Ltd:, Hitachi Elevator (China) China) Co:, Ltd:, Kone Elevator Co:, Ltd:, Otis Elevator (China) Investment Co:, Ltd:, Shanghai Mitsubishi Elevator Co:, Ltd:, Disheng Elevator (Shanghai) Co:, Ltd:, Jianyan Machinery Inspection and Testing (Beijing) Co:, Ltd:, Guangdong Special Equipment Inspection and Research Institute, Henan Special Equipment Safety Full Testing Research Institute, Chongqing Special Equipment Testing Research Institute, Shenzhen Quality and Safety Inspection and Testing Research Institute, Suzhou Jiangnan Jiajie Elevator Co:, Ltd: Company, Shanghai Edunburgh Elevator Group Co:, Ltd:, Yongda Elevator Equipment (China) Co:, Ltd:, Shandong Fuji Control Elevator Co:, Ltd:, Hangzhou Aolida Elevator Co:, Ltd:, Huasheng Fujitec Elevator Co:, Ltd:, Guangzhou Guangri Elevator Industry Co:, Ltd:, CANNY Elevator Co:, Ltd: Company, Xiji Schindler Elevator Co:, Ltd:, Weber Elevator Co:, Ltd:, Hangzhou Theo Elevator Co:, Ltd:, Southeast Elevator Co:, Ltd:, Ling Wang Elevator Co:, Ltd:, Sicher Elevator Co:, Ltd:, Giant Kone Elevator Co:, Ltd:, Guangdong Suzuki Elevator Co:, Ltd:, Shandong Best Elevator Co:, Ltd:, Tongyou Elevator Co:, Ltd: The main drafters of this document: Liu Wenchao, Chen Jun, Lin Jianjie, Chang Xiaoqing, Chen Fengwang, Liang Yanjun, Xu Yehua, Sun Jian, Li Qing, Wu Wei, Zhang Shoulin, Jin Zhiyong, Dong Yugang, Zhang Huajun, Tang Yuelin, Lu Zhifeng, Zhou Weidong, Song Yuqing, Xu Xiaochuan, Wang Yulei, Wu Xianzhou, Xi Junxia, Tan Zhengrong, Zhao Jianbing, Gao Qipeng, Zhang Jianwei, Yao Yifeng, Xu Peigen, Li Weiquan, Sun Yan, Liang Lipan, Lu Weili, Li Yan, Xu Ming: The release status of previous versions of this document and the documents it replaces are as follows: ---It was first published as GB 7025-1986 in 1986; --- When it was revised for the first time in:1997, it was issued as GB/T 7025:1-1997, and it was revised for the second time in:2008; --- This is the third revision:

Introduction

0:1 The design parameters of elevators caused by elevator types and intended uses are relatively complex, and the range of design parameters for each elevator type is different: Are not the same: In order to provide guidance in the preliminary planning stage of the building, make full use of the space, standardize the parameters of the elevator, and facilitate the elevator related parties to choose the elevator According to the different types of elevators, my country has established the main parameters of the elevator and the parameters of the car, hoistway, and machine room to support the elevator safety standards: National standard system of types and dimensions: GB/T 7025 "Elevator Main Parameters and Types and Dimensions of Cars, Shafts, and Machine Rooms" is my country's elevator standard The basic standard of the quasi-system consists of three parts: --- Part 1: Class I, II, III, VI elevators: The purpose is to specify the necessary dimensions required for passenger lifts: --- Part 2: Class IV elevators: The purpose is to specify the necessary dimensions required for freight elevators: --- Part 3: Class V elevators: The purpose is to specify the necessary dimensions required for a lift: 0:2 This document reflects the needs of the market, including: ---Special needs of users, including those with physical disabilities, requirements for convenience and mobility; --- Appropriate use of stretchers, beds and paramedical equipment in hospitals and nursing homes; --- Frequently used elevators with a rated speed of 2:5m/s~6:0m/s usually run in high-rise buildings; --- Elevators whose rated speed does not exceed 2:5m/s determined based on the priority number system; --- Where feasible, reduce the size of the shaft to improve the utilization of building space: Elevator main parameters and car, shaft, The type and size of the computer room Part 1: Elevators of categories Ⅰ, Ⅱ, Ⅲ and Ⅵ

1 Scope

This document specifies the dimensions required for the installation of elevators of categories I, II, III and VI: The dimensions given in this document reflect the requirements for the installation of elevators and their equipment: This document applies to all lifts installed in new buildings with a single car or a through-entrance and with a drive system irrelevant: This document also applies to elevators installed in existing buildings: This document does not apply to lifts whose rated speed exceeds 6:0m/s:

2 Normative references

This document has no normative references:

3 Terms and Definitions

The following terms and definitions apply to this document: 3:1 General terms and definitions 3:1:1 car car Elevator components used to carry passengers and/or other loads: 3:1:2 top-level headroom The part of the hoistway (3:1:8) between the highest floor station (3:1:3) served by the car (3:1:1) and the top of the hoistway: 3:1:3 floor station landing Each floor is used to enter and exit the place of the car (3:1:1): 3:1:4 machine room A dedicated room for installing one or more drive hosts and their ancillary equipment: 3:1:5 machineroom-lesslift The machine space (such as the space for placing the control cabinet and the drive system, the drive host, the main switch and the emergency operating device, etc:) is located in the hoistway Elevators (3:1:6) within (3:1:8) or on landings (3:1:3): 3:1:6 lift; elevator Serving several specific floors in a building, the car (3:1:1) runs on a rigid guide rail with an inclination angle of less than 15° to the vertical
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 7025.1-2023_English be delivered?

Answer: Upon your order, we will start to translate GB/T 7025.1-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 7025.1-2023_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 7025.1-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 7025.1-2023?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 7025.1-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.