Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 5475-2013 English PDF

US$78.00 ยท In stock
Delivery: <= 1 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 5475-2013: Methods for sampling ion exchange resins
Status: Valid

GB/T 5475: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 5475-201378 Add to Cart 1 days Methods for sampling ion exchange resins Valid
GB/T 5475-1985199 Add to Cart 2 days Methods for sampling ion exchange resins Obsolete

Similar standards

GB/T 6595   GB/T 6344   GB/T 6669   GB/T 5474   GB/T 5473   GB/T 5476   

Basic data

Standard ID: GB/T 5475-2013 (GB/T5475-2013)
Description (Translated English): Methods for sampling ion exchange resins
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: G31
Classification of International Standard: 83.080.10
Word Count Estimation: 5,541
Older Standard (superseded by this standard): GB/T 5475-1985
Regulation (derived from): National Standards Bulletin 2013 No. 17
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies: wet resin ion exchange sampling methods. This standard applies to: wet ion exchange resins sampling.

GB/T 5475-2013: Methods for sampling ion exchange resins

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for samping ion exchange resins ICS 83.080.10 G31 National Standards of People's Republic of China Replacing GB/T 5475-1985 Ion exchange resin sampling Issued on. 2013-09-06 2014-01-31 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard is prepared in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 5475-1985 "ion exchange resin sampling method", compared with the GB/T 5475-1985, the main technical change Of the following. --- Amend the provisions of the sampling tool. The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Standardization Technical Committee plastic universal methods and products Club (SAC/TC15/SC4) centralized. This standard was drafted. Xi'an Thermal Power Research Institute Co., Ltd., Zibo East Chemical Co., Ltd., the National Quality Supervision, synthetic resin Inspection Center, Ningbo win glory Resin Co., Ltd., Jiangsu Su Qing water treatment engineering company. The main drafters. Zhang Peng Hua, Cuihuan Fang, Di Jinghua, Hu Jinjiang, Cai Xiaohua, Wangyong Gui. This standard replaces the standards previously issued as follows. --- GB/T 5475-1985. Ion exchange resin sampling

1 Scope

This standard specifies the method for sampling wet resin ion exchange. This standard applies to sampling wet ion exchange resin.

2 instruments and devices

2.1 Sampler 2.1.1 Material. stainless steel or plastic. 2.1.2 Size. inner diameter of 25mm ~ 30mm, opening width of 18mm ~ 20mm, the length of the opening is not less than the ion exchange resin storey 80% of degrees. As shown in Figure 1. The total length of the sampler can adjust the height of the exchange resin layer according to the container lon sampler probe into the bottom of the container opening paragraph After the trailing end of the surface layer is higher than the ion exchange resin is not less than 200mm. Note. The sub-sampler can be made to facilitate different ion exchange resin layer height of specimen sampling. Millimeters Figure 1 Sampler 2.2 points like container Flat enamel or plastic container. 2.3 sample container Clean sealable container.

3 Sampling Rules

3.1 Sampling We need resin samples from the same batch of ion exchange, when there are n the package, when n is less than or equal to 3.00 each sample shall not be less than 3; when n is greater than 3.00 to take a random sampling method, the total number of samples calculated according to the formula n 1 (whichever occurs decimals rounded up method Integer), each sample shall not be less than 2 times.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 5475-2013_English be delivered?

Answer: Upon your order, we will start to translate GB/T 5475-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically in 24 hours. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 5475-2013_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 5475-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 5475-2013?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5475-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.