GB/T 5275.11-2014 English PDFUS$294.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 5275.11-2014: Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 11: Electrochemical generation Status: Valid
Basic dataStandard ID: GB/T 5275.11-2014 (GB/T5275.11-2014)Description (Translated English): Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 11: Electrochemical generation Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G86 Classification of International Standard: 71.040.40 Word Count Estimation: 15,117 Date of Issue: 7/8/2014 Date of Implementation: 12/1/2014 Quoted Standard: ISO 6143; ISO 6145-1; GB/T 5275.7-2014 Adopted Standard: ISO 6145-11-2005, IDT Regulation (derived from): 2014 National Standards Bulletin No. 18 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the method for generating calibration components by electrochemical method and introduced into a carrier gas stream prepared calibration gas mixture. Changed by changing the gas flow rate through the electrolytic cell or to change GB/T 5275.11-2014: Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 11: Electrochemical generation---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. . Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 11. Electrochemical generation ICS 71.040.40 G86 National Standards of People's Republic of China Gas analysis prepared dynamic volume Method Calibration gas mixtures Part 11. Electrochemical method occurs volumetricmethods-Part 11. Electrochemicalgeneration (ISO 6145-11.2005, IDT) Issued on. 2014-07-08 2014-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordGB/T 5275 "gas analysis dynamic volume Preparation of calibration gas mixtures" is divided into the following sections. --- Part 1. calibration method; --- Part 2. positive displacement pump; --- Part 4. continuous injection; --- Part 5. Capillary calibration devices; --- Part 6. Critical orifices; --- Part 7. Thermal mass flow controller; --- Part 8. Diffusion method; --- Part 9. Saturation method; --- Part 10. Permeation; --- Part 11. Electrochemical method occurs. This section GB/T 5275 Part 11. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the translation method identical with ISO 6145-11.2005 "gas analysis dynamic volume Preparation of calibration gas mixtures article Part 11. Electrochemical Method happen. " Consistency correspondence between this part of international documents and normative references of our files are as follows. --- GB/T 5275.1-2014 gas analysis equipment dynamic volume Method of calibration gas mixtures - Part 1. calibration method (ISO 6145-1.2003, IDT); --- GB/T 10628-2008 gas analysis calibration gas mixture composition measurements and calibration comparison (ISO 6143.2001, IDT). This part is proposed by the China Petroleum and Chemical Industry Association. This part of the National Gas Standardization Technical Committee (SAC/TC206) centralized. This section drafted by. China Institute of Metrology, Southwest Chemical Industry Research and Design Institute Limited. The main drafters of this section. Zhang Zhuang, Chen Yali. Gas analysis prepared dynamic volume Method Calibration gas mixtures Part 11. Electrochemical method occurs1 ScopeGB/T 5275 provisions of this part of the component calibration gas mixture generated by electrochemical method and introduced into the carrier gas flow calibration preparation Methods. Changed by changing the gas flow rate through the electrolytic cell or to change the composition of the charge gas mixture. Calibration gas mixture content Relative expanded uncertainty U by the relative combined standard uncertainty multiplied by a coverage factor k = 2 obtained, its value is not more than 5%. The preparation method for the preparation of multi-part predetermined volume fraction in the range of 0.1 × 10-6 ~ 250 × 10-6 calibration mixed gas. Note 1. The gas generating electrochemical method available include oxygen (O2), hydrogen (H2), hydrogen cyanide (HCN), hydrogen sulfide (H2S), chlorine (Cl2), bromine (Br2), dioxane Chloride (ClO2), ammonia (NH3), nitric oxide (NO), nitrogen (N2), carbon dioxide (CO2), phosphine (PH3), arsine (AsH3) and ozone (O3). Note 2. The advantage of electrochemical law capable of producing stable calibration gas mixture quickly within a few minutes. Note 3. The gas mixing system with an electrochemical gas generating device and a thermal mass flow controller, is equipped with computers and automatic control device, can be Commercial development. Examples See Appendix A.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. ISO 6143 Gas analysis calibration gas mixture composition measurements and check Comparative Law (Gasanalysis-Comparison methodsfordeterminingandcheckingthecompositionofcalibrationgasmixtures) ISO 6145-1 Gas analysis dynamic volume Preparation of calibration gas mixtures - Part 1. calibration method (Gasanalysis- Preparationofcalibrationgasmixturesusingdynamic volumetricmethods-Part 1. Methodsofcali- bration) GB/T 5275.7-2014 gas analysis dynamic volume Preparation of calibration gas mixtures - Part 7. Thermal mass flow controller Troller (ISO 6145-7.2009, IDT)3 Steps3.1 Principle The electrochemical method is the basic method of the occurrence of gas produced, the occurrence of electrochemical method, the calibration component is generated by an amount proportional to the amount of the charge, Faraday constant scale factor [1mol electrons (or single-charged ions) the amount of charge transferred] reciprocal equals Avogadro's number (NA) And the charge of an electron (-e) of the product. F = NA × e (1) Where. F --- 96485.3415C/mol, the relative uncertainty of 4.0 × 10-8 (see reference [1], [2] and [3]). Chapter 5 given as long as conditions are met, the exact determination of the amount of gas current can be determined by cell produced. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5275.11-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 5275.11-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 5275.11-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5275.11-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |