GB/T 5275.10-2009 English PDFUS$314.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 5275.10-2009: Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 10: Permeation method Status: Valid
Basic dataStandard ID: GB/T 5275.10-2009 (GB/T5275.10-2009)Description (Translated English): Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 10: Permeation method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G86 Classification of International Standard: 71.040.40 Word Count Estimation: 16,147 Date of Issue: 2009-06-02 Date of Implementation: 2010-02-01 Older Standard (superseded by this standard): GB/T 5275-2005 Quoted Standard: ISO 6145-1 Adopted Standard: IEC 6145-10-2002, IDT Regulation (derived from): National Standard Approval Announcement 2009 No.8 (Total No.148) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the method using mixed gas permeation membranes prepared dynamic volume calibration. This method of calibration gas mixture prepared with the components of the mole fraction range from 10-9 to 10-5, the relative expanded uncertainty of 2. 5 %. Because in such a low range to keep the content of the calibration gas mixture components weighed unchanged is difficult, therefore the preparation of calibration gas mixtures should be used when temporary, and delivery piping should make full short. The technology has such an air of SO2 in the preparation of low levels of calibration gas mixtures, NO2, C2H6 and other fields has been successfully applied. GB/T 5275.10-2009: Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 10: Permeation method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Gas analysis.Preparation of calibration gas mixtures using dynamic volumetric methods.Part 10. Permeation method ICS 71.040.40 G86 National Standards of People's Republic of China GB/T 5275.10-2009/ISO 6145-10.2002 Replacing GB/T 5275-2005 Gas Analysis Dynamic volume Preparation of calibration gas mixtures Part 10. Permeation (ISO 6145-10.2002, IDT) Posted 2009-06-02 2010-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordGB/T 5275 "gas analysis dynamic volume Preparation of calibration gas mixtures" is expected to be divided into 11 parts. --- Part 1. Calibration; --- Part 2. positive displacement pump; --- Part 3 .( unavailable); --- Part 4. continuous injection; --- Part 5. Capillary calibration devices; --- Part 6. Critical orifices; --- Part 7. Thermal mass drive controller; --- Part 8. Diffusion method; --- Part 9. Saturation method; --- Part 10. Permeation; --- Part 11. Electrochemical method occurs. This section GB/T 5275 Part 10. This part identical with ISO 6145-10.2002 "gas analysis dynamic volume Preparation of calibration gas mixtures - Part 10. Infiltration Through Law. " This Part replaces GB/T 5275-2005 "gas analyzer calibration method for preparing a mixed permeate gas." The main difference compared to part with the GB/T 5275-2005 as follows. --- Increasing the reagents and materials requirements (Chapter 4 of this section); --- The "Application examples" (GB/T 35275-2005 of Cap) into "device" (Chapter 5 of this section), "Program" (this Part 6) two chapters were described in detail; --- Modify the calculation method (GB/T 5275-2005 4.2 This section 7.1); --- The "error" (GB/T 5275-2005 4.1) to "uncertainty" and increased uncertainties in the calculation of (in this section 7.3); --- Modify the sources of uncertainty (GB/T 5275-2005 4.1 This section 6.2); --- Increasing the sample calculation Uncertainty Double scale continuous weighing system as Appendix A (in this section in Appendix A). This section of Appendix A normative appendix. This part is proposed by the China Petroleum and Chemical Industry Association. This part of the National Gas Standardization Technical Committee (SAC/TC206) centralized. This section drafted by. China Institute of Metrology, Southwest Chemical Industry Research and Design Institute. The main drafters of this section. Jin Meilan, Liang Jianping, Chen Yali. This part of the standard replaces the previous editions are. --- GB/T 5275-1985, GB/T 5275-2005. GB/T 5275.10-2009/ISO 6145-10.2002 Gas Analysis Dynamic volume Preparation of calibration gas mixtures Part 10. Permeation1 ScopeGB/T 5275 provisions of this part of the dynamic membrane permeation volume Preparation of calibration gas mixtures approach. In this way the system Calibration prepared by mixing the components of the gas mole fraction in the range of 10-9 ~ 10-6, the relative expanded uncertainty of 2.5%. Since this Within a range to maintain the kind of low-component calibration gas mixture remains solid content is difficult, so calibration gas mixtures to be used in temporary Preparation and delivery piping should be as short as possible. Calibration The technology has been in the preparation of a low level of gas mixtures such as air SO2, NO2, C2H6 And other fields has been successfully applied. When the carrier gas flow rate of gas mass flow measurement result by permeation control equipment calibration method of mixing the gas component is a dynamic volume Law and the law gives the content of component mole fraction form.2 Normative referencesThe following documents contain provisions cited by GB/T 5275 to the present, constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. ISO 6145-1 Gas analysis dynamic volume Preparation of calibration gas mixtures - Part 1. Calibration Principle 3 Calibration components such as SO2, NO2, ammonia (NH3), benzene, toluene, xylene permeation through appropriate into a carrier gas stream, i.e., to obtain the calibration mixed composition. The component known purity calibration gas containing the permeate tube, the permeation tube is placed in a temperature-controlled container, with known traffic And subject to the control of the carrier gas purge this vessel. Content of the mixed gas by the flow rate of the constituent components of the gas permeability and high purity carrier gas to determine Given that the gas component and should not be and should not permeate tube of material from any chemical interference in the gas mixture to any other trace components by gas reaction. Component calibration gas permeability through the membrane component depends on the nature of the material itself, the chemical properties of the membrane, structure, size, thickness, temperature Degree and component calibration gas permeable membrane through the partial pressure gradient. These factors can be kept constant by a suitable operation system. The permeate tube was placed on a microbalance, through its continuously or periodically weighed, can be directly measured permeability.4 Reagents and materialsOsmoticum 4.1 for calibration Should be chosen as high purity material as permeate, to avoid the effects of impurities on which the permeation rate; if not possible you should know Track the content and nature of impurities, and should consider the impact of these factors on permeability impurities. 4.2 The carrier gas Application of appropriate methods of analysis to determine its purity, for example, gas chromatography (GC) or Fourier Transform Infrared Spectroscopy (FTIR). GB/T 5275.10-2009/ISO 6145-10.2002 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5275.10-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 5275.10-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 5275.10-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5275.10-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |