GB/T 41394-2022 English PDFUS$589.00 ยท In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 41394-2022: Functional safety requirements of overfill prevention systems on explosive dangerous chemical Status: Valid
Basic dataStandard ID: GB/T 41394-2022 (GB/T41394-2022)Description (Translated English): Functional safety requirements of overfill prevention systems on explosive dangerous chemical Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: N10 Word Count Estimation: 30,318 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 41394-2022: Functional safety requirements of overfill prevention systems on explosive dangerous chemical---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Functional safety requirements of overfill prevention systems on explosive dangerous chemical ICS 25.040 CCSN10 National Standards of People's Republic of China Explosion-hazardous chemical storage tank overflow prevention system Functional Safety Requirements Published on 2022-04-15 2022-11-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration directory Preface III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Abbreviations 4 5 General requirements for tank overflow prevention systems 4 5.1 General requirements 4 5.2 Storage tank monitoring method and classification of overfill prevention system instrumentation configuration 5 5.3 Full life cycle functional safety requirements of tank overflow prevention system 6 6 Safety management requirements for storage tank overflow prevention 6 6.1 General requirements6 6.2 Focus on level management and periodic review requirements7 6.3 Functional Safety Assessment Requirements for Tank Overfill Prevention Systems 7 6.4 Requirements for the safety management system for tank overflow prevention 7 6.5 Requirements for safety regulations for tank overflow prevention operation 7 6.6 Requirements for emergency plan for tank overflow accident 9 7 Tank overflow risk assessment9 7.1 General requirements9 7.2 Risk Assessment Implementation Requirements 9 8 Allocation of safety requirements for tank overflow prevention systems 9 8.1 General requirements9 8.2 Security Requirements Assignment Implementation Requirements 10 9 Design requirements for tank overflow prevention system 10 9.1 General requirements 10 9.2 Level-focused design 10 9.3 Classification and composition of tank overflow prevention systems 13 9.4 Functional Safety Design of AOPS 13 9.5 Safety protection design of tank overflow prevention system 19 10 Installation Requirements for Tank Overfill Prevention System 19 11 Requirements for safety confirmation before the operation of the storage tank overflow prevention system 19 11.1 Installation Confirmation Requirements 19 11.2 Hardware Validation Requirements 20 11.3 Functional Validation Requirements 20 11.4 Application Confirmation Requirements 21 11.5 Requirements for Operational Confirmation 21 12 Acceptance Requirements for Tank Overfill Prevention Systems 21 13 Requirements for Inspection, Testing and Maintenance of Tank Overfill Prevention Systems 21 13.1 General requirements 21 13.2 Technical requirements 21 14 Change Management Requirements for Tank Overfill Prevention Systems 22 14.1 General requirements 22 14.2 Change Management Requirements 22 14.3 Changed Documentation Requirements 23 15 Decommissioning Requirements for Tank Overfill Prevention Systems 23 Appendix A (Informative) Installation Requirements for Liquid Level Detection Instruments 24 Reference 25 Figure 1 General technical model of tank overflow prevention system 5 Figure 2 Tank concerned about liquid level 11 Table 1 Storage tank monitoring method and instrument configuration classification of overflow prevention system 6 Table 2 The classification of storage tank monitoring methods and the setting of the liquid level of concern Table 11 Table A.1 Installation requirements for liquid level detection instruments 24 forewordThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents" drafted. Please note that some content of this document may be patented. The issuing agency of this document assumes no responsibility for identifying patents. This document is proposed by China Machinery Industry Federation. This document is under the jurisdiction of the National Technical Committee on Standardization of Industrial Process Measurement Control and Automation (SAC/TC124). This document is drafted by. Machinery Industry Instrumentation Comprehensive Technology and Economic Research Institute, Dandong Tongbo Electric (Group) Co., Ltd., China Stone Oil Group Safety and Environmental Protection Technology Research Institute Co., Ltd., China National Petroleum and Natural Gas Pipeline Engineering Co., Ltd., Nanjing University of Science and Technology, Honeywell (China) China) Co., Ltd. The main drafters of this document. Liu Yao, Shuai Bing, Lu Dongfeng, Bu Zhijun, Zhang Yiding, Shi Xueling, Zhu Minglu, Wei Zhenqiang, Li Zujun, Guo Yonggang, Xu Deteng, Chen Xiaohua, Zhang Zhanfeng, Tao Ming, Qian Fuqun, Wei Haiyang, Shi Suijing, Yu Shiheng, Wang Lu, Yang Liu, Li Qiujuan, Sun Teng, Chen Hongxin, Qian Hua, Zhu Xuying, Wang Gang, Zhang Yabin, Duan Dongde, Liu Jingjing, Wang Rongzhen, Liu Wencai, Xiong Wenze.IntroductionIn oil reservoir areas, chemical parks and hazardous chemical related operating units, hazardous chemical storage tanks are a major source of danger. It may lead to fire and explosion, resulting in heavy casualties and economic losses, and the risk is extremely high. The necessary means of storage tank overflow risk, in order to protect the life and property safety of the people, the full life cycle functional safety of the storage tank overflow prevention system should be realized. Guarantee is important. This document is aimed at safety management, risk assessment, safety requirement assignment, design, safety Safety-related requirements and technical methods are put forward for installation, commissioning, evaluation, acceptance, maintenance and decommissioning activities, so as to provide safety-related requirements and technical methods for the entire life cycle of the storage tank overflow prevention system. The participants at the stage provide work basis to improve the risk management and control ability and intrinsic safety level of my country's hazardous chemical storage links. The purpose of this document is to guide and standardize the protection of fixed petroleum and other hazardous chemicals liquid storage tanks in petroleum and hazardous chemicals related fields. Full-lifecycle functional safety activities for overflow systems. Explosion-hazardous chemical storage tank overflow prevention system Functional Safety Requirements1 ScopeThis document specifies the functional safety requirements for the installation of tank overflow prevention systems for hazardous chemical storage tanks. This document is applicable to above-ground fixed atmospheric pressure storage tanks for petroleum and other hazardous chemicals above 5m3.5m3 and below fixed Liquid atmospheric storage tanks can be implemented by reference. This document does not apply to LPG/LNG tanks, dedicated buffer tanks, engine fuel tanks, heating tanks, scavengers only from wheeled Tanks for tank cars (such as tank cars or railroad tank cars).2 Normative referencesThe contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document. GB/T 20438.2-2017 Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems Part 2.Electrical/Electronic/ Requirements for programmable electronic safety-related systems GB/T 20438.3-2017 Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Systems Part 3.Software Requirements GB/T 21109.1-2007 Functional Safety of Safety Instrumented Systems in the Process Industry Part 1.Framework, Definition, System, Hardware software and software requirements GB/T 29639 Guidelines for the preparation of emergency plans for production safety accidents in production and business units GB 50093 Code for Construction and Quality Acceptance of Automation Instrumentation Engineering3 Terms and DefinitionsThe following terms and definitions apply to this document. 3.1 alarm Audible and/or visual indications to operators of equipment failures, process deviations, or other abnormal conditions requiring prompt response. 3.2 alert alert When the operator's pre-defined operating conditions have reached a certain value, using sound and/or light to prompt the operator. NOTE. The purpose of the alert is to remind the user/operator that an investigation or other corresponding action needs to be performed. 3.3 atmospheric tank A storage tank with a design pressure of less than 0.1MPa, built on the ground, and storage of non-artificial refrigeration, non-toxic petroleum, chemical and other liquid media. 3.4 Pay attention to the level of concern; LOC The owner or operator sets the appropriate warning level, alarm level and automatic overfill prevention function of the tank by calculating the medium level of the tank. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 41394-2022_English be delivered?Answer: Upon your order, we will start to translate GB/T 41394-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 41394-2022_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 41394-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |