Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 37733.1-2019 PDF English

US$199.00 · In stock · Download in 9 seconds
GB/T 37733.1-2019: Sensor networks -- Remote personal health status monitoring -- Part 1: General technical requirements
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
GB/T 37733.1-2019199 Add to Cart 3 days Sensor networks -- Remote personal health status monitoring -- Part 1: General technical requirements Valid

Similar standards

GB/T 37684   GB/T 38322   GB/T 37685   GB/T 37733.3   

GB/T 37733.1-2019: Sensor networks -- Remote personal health status monitoring -- Part 1: General technical requirements


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT37733.1-2019
Sensor networks - Remote personal health status monitoring - Part 1. General technical requirements ICS 35.110 L79 National Standards of People's Republic of China Sensor network personal health status remote monitoring Part 1. General technical requirements Sensornetworks-Remotepersonalhealthstatusmonitoring- Part 1. Generaltechnicalrequirements Published on.2019-08-30 2020-03-01 implementation State market supervision and administration China National Standardization Administration issued Content Foreword I 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 system overall architecture 2 5 terminal requirements 3 6 Network Requirements 3 7 Platform Requirements 3 8 personal health remote monitoring data requirements 4 Appendix A (informative) Personal Health Data Example 5 Appendix B (informative) Personal Health Status Remote Monitoring Application Scenario 6

Foreword

GB/T 37733 "Remote Monitoring of Personal Health Status of Sensor Networks" is divided into the following three parts. --- Part 1. General technical requirements; --- Part 2. Terminal and platform interface technical requirements; --- Part 3. Terminal technical requirements. This part is the first part of GB/T 37733. This part is drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This part is proposed and managed by the National Information Technology Standardization Technical Committee (SAC/TC28). This section drafted by. China Electronics Technology Standardization Institute, Beijing Shuguang Yitong Technology Co., Ltd., Chongqing University of Posts and Telecommunications, Shanghai En Valley Information Technology Co., Ltd., Putian Information Technology Co., Ltd., BOE Technology Group Co., Ltd., Shandong Province Computing Center (National Super Level calculation Jinan Center), Xi'an Aerospace Stellar Technology Industrial (Group) Co., Ltd., Beijing Bichuang Technology Co., Ltd., Shenzhen Standardization Institute, Jilin Provincial Standards Research Institute, China Center for Disease Control and Prevention, Nutrition and Health Institute, Wuxi Internet of Things Industry Research Institute, Southeast University, Affiliated Hospital of Jiangnan University. The main drafters of this section. Yang Hong, Yu Xueping, Su Jingru, Guo Xiong, Wang Wei, Xu Zhiguang, Liu Jingwen, Zhang Xu, Shu Minglei, Song Yang, Tian Jian, Chen Jian, Chen Demin, Zhang Xujie, Li Chunhong, Xu Wei, Pu Lingfeng, Shan Yu, Wang Jia, Tang Zhibin, Yi Xiaoshan, Xu Bai, Liu Jing, Wan Likui, Wang Wei, Xing Tao, Qian Weilin, Xu Pingping, Fang Ningsheng, Liu Li, Zhou Junhua. Sensor network personal health status remote monitoring Part 1. General technical requirements

1 Scope

This part of GB/T 37733 specifies the overall architecture and terminal requirements of the personal health status remote monitoring system based on sensor networks. Network requirements, platform requirements, and personal health monitoring data requirements. This section applies to the design and development of a personal health status remote monitoring system based on sensor networks.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 30269.2-2013 Information technology sensor networks - Part 2. Terminology GB/T 30269.501-2014 Information technology sensor networks - Part 501. Identification. rule

3 Terms and definitions

The following terms and definitions as defined in GB/T 30269.2-2013 apply to this document. 3.1 Personal health data personalhealthdata Vital signs data collected by personal health equipment as basic data for personal health remote monitoring, including but not limited to ECG, blood Pressure, blood oxygen, breathing, body temperature, blood sugar, etc. Note. referred to as data. 3.2 Personal health terminal personalhealthterminal Logical entity with personal vital signs data collection, processing, storage and transmission capabilities, by personal health devices and personal health gateways composition. Note. referred to as the terminal. 3.3 Personal health equipment personalhealthdevice One of the components of the terminal, a physical entity for collecting and measuring personal health data, with data collection capabilities and data availability Processing and storage capabilities need to be powered by a power source, examples include pulse oximeters, blood pressure monitors, thermometers, or weighing scales. Note. referred to as equipment. 3.4 Personal health sensor node personalhealthsensornode A component of the device that is used to collect sensor nodes for personal health data. Note. referred to as the node. GB/T 37733.1-2019 Sensor networks - Remote personal health status monitoring - Part 1. General technical requirements ICS 35.110 L79 National Standards of People's Republic of China Sensor network personal health status remote monitoring Part 1. General technical requirements Sensornetworks-Remotepersonalhealthstatusmonitoring- Part 1. Generaltechnicalrequirements Published on.2019-08-30 2020-03-01 implementation State market supervision and administration China National Standardization Administration issued Content Foreword I 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 system overall architecture 2 5 terminal requirements 3 6 Network Requirements 3 7 Platform Requirements 3 8 personal health remote monitoring data requirements 4 Appendix A (informative) Personal Health Data Example 5 Appendix B (informative) Personal Health Status Remote Monitoring Application Scenario 6

Foreword

GB/T 37733 "Remote Monitoring of Personal Health Status of Sensor Networks" is divided into the following three parts. --- Part 1. General technical requirements; --- Part 2. Terminal and platform interface technical requirements; --- Part 3. Terminal technical requirements. This part is the first part of GB/T 37733. This part is drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This part is proposed and managed by the National Information Technology Standardization Technical Committee (SAC/TC28). This section drafted by. China Electronics Technology Standardization Institute, Beijing Shuguang Yitong Technology Co., Ltd., Chongqing University of Posts and Telecommunications, Shanghai En Valley Information Technology Co., Ltd., Putian Information Technology Co., Ltd., BOE Technology Group Co., Ltd., Shandong Province Computing Center (National Super Level calculation Jinan Center), Xi'an Aerospace Stellar Technology Industrial (Group) Co., Ltd., Beijing Bichuang Technology Co., Ltd., Shenzhen Standardization Institute, Jilin Provincial Standards Research Institute, China Center for Disease Control and Prevention, Nutrition and Health Institute, Wuxi Internet of Things Industry Research Institute, Southeast University, Affiliated Hospital of Jiangnan University. The main drafters of this section. Yang Hong, Yu Xueping, Su Jingru, Guo Xiong, Wang Wei, Xu Zhiguang, Liu Jingwen, Zhang Xu, Shu Minglei, Song Yang, Tian Jian, Chen Jian, Chen Demin, Zhang Xujie, Li Chunhong, Xu Wei, Pu Lingfeng, Shan Yu, Wang Jia, Tang Zhibin, Yi Xiaoshan, Xu Bai, Liu Jing, Wan Likui, Wang Wei, Xing Tao, Qian Weilin, Xu Pingping, Fang Ningsheng, Liu Li, Zhou Junhua. Sensor network personal health status remote monitoring Part 1. General technical requirements

1 Scope

This part of GB/T 37733 specifies the overall architecture and terminal requirements of the personal health status remote monitoring system based on sensor networks. Network requirements, platform requirements, and personal health monitoring data requirements. This section applies to the design and development of a personal health status remote monitoring system based on sensor networks.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 30269.2-2013 Information technology sensor networks - Part 2. Terminology GB/T 30269.501-2014 Information technology sensor networks - Part 501. Identification. rule

3 Terms and definitions

The following terms and definitions as defined in GB/T 30269.2-2013 apply to this document. 3.1 Personal health data personalhealthdata Vital signs data collected by personal health equipment as basic data for personal health remote monitoring, including but not limited to ECG, blood Pressure, blood oxygen, breathing, body temperature, blood sugar, etc. Note. referred to as data. 3.2 Personal health terminal personalhealthterminal Logical entity with personal vital signs data collection, processing, storage and transmission capabilities, by personal health devices and personal health gateways composition. Note. referred to as the terminal. 3.3 Personal health equipment personalhealthdevice One of the components of the terminal, a physical entity for collecting and measuring personal health data, with data collection capabilities and data availability Processing and storage capabilities need to be powered by a power source, examples include pulse oximeters, blood pressure monitors, thermometers, or weighing scales. Note. referred to as equipment. 3.4 Personal health sensor node personalhealthsensornode A component of the device that is used to collect sensor nodes for personal health data. Note. referred to as the node. ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of GB/T 37733.1-2019 be delivered?Answer: The full copy PDF of English version of GB/T 37733.1-2019 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 37733.1-2019_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 37733.1-2019_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 37733.1-2019 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of GB/T 37733.1-2019?

A step-by-step guide to download PDF of GB/T 37733.1-2019_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 37733.1-2019".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9