GB/T 37317-2019 English PDFUS$439.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 37317-2019: Railway applications - Guide for lightning protection of DC overhead contact system Status: Valid
Basic dataStandard ID: GB/T 37317-2019 (GB/T37317-2019)Description (Translated English): Railway applications - Guide for lightning protection of DC overhead contact system Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: S35 Classification of International Standard: 29.280 Word Count Estimation: 22,286 Date of Issue: 2019-03-25 Date of Implementation: 2019-10-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 37317-2019: Railway applications - Guide for lightning protection of DC overhead contact system---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Railway applications--Guide for lightning protection of DC overhead contact system ICS 29.280 S35 National Standards of People's Republic of China Rail Guide for lightning protection of overhead overhead contact networks Published on.2019-03-25 2019-10-01 implementation State market supervision and administration China National Standardization Administration issued ContentForeword III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Lightning activity characterization 3 5 Lightning protection principle 3 6 Lightning protection measures 4 7 Lightning protection measures implementation 5 Appendix A (informative appendix) Schematic diagram of installation of overhead earth line and out-of-band series gap metal oxide arrester 8 Appendix B (informative appendix) Calculation results of lightning strike rate after overhead contact network using lightning protection measures for overhead ground lines Appendix C (informative) Working principle and main technical parameters of lightning surge grounding device 12 Appendix D (informative) Typical structure type and main technical parameters of out-of-band series gap metal oxide arresters Reference 17ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This standard was proposed by the National Railway Administration. This standard is supported by the National Traction Electrical Equipment and Systems Standardization Technical Committee (SAC/TC278) and the National Lightning Protection Standardization Technology. The committee (SAC/TC258) is under the jurisdiction. This standard is drafted by. Tianjin China Railway Electrification Design and Research Institute Co., Ltd., China Electric Power Research Institute Co., Ltd. Participated in the drafting of this standard. Beijing Electric Power Economic and Technological Research Institute, State Grid Electric Power Research Institute Wuhan Nanrui Co., Ltd., Guang State Subway Group Co., Ltd. The main drafters of this standard. Wang Litian, Chen Weijiang, Shen Haibin, Zhao Haijun, Bian Kai, Xiang Nianwen, Huang Deliang, Wang Yanli. Rail Guide for lightning protection of overhead overhead contact networks1 ScopeThis standard stipulates the lightning protection principle, protective measures and implementation plan for overhead contact network of urban rail transit. This standard is applicable to urban rail transit ground and elevated section overhead contact nets with DC 1500V traction power supply, using DC Ground and overhead section overhead contact nets with traction power of 750V and below can be implemented by reference.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 11032 AC gapless metal oxide arrester GB/T 25890.5 Rail switch ground equipment - Part 5. DC arresters and low-voltage limiters GB/T 32520 AC 1OV or more with external series gap metal oxide arrester (EGLA) for overhead transmission and distribution lines GB/T 50064-2014 AC electrical equipment overvoltage protection and insulation coordination design specifications3 Terms and definitionsThe following terms and definitions apply to this document. 3.1 Cloud flash intra-clouddischarge The phenomenon of atmospheric discharge occurring inside the same cloud and between different clouds. 3.2 Ground flash cloud-to-groundlightningflash Atmospheric discharge between the cloud and the earth or ground. Note. Rewrite GB/T 21714.1-2015, definition 3.1. 3.3 Lightning strikening A single air-to-cloud discharge. Note. Rewrite GB/T 21714.1-2015, definition 3.4. 3.4 Lightning current The current flowing through the lightning strike point. [GB/T 21714.1-2015, definition 3.9] 3.5 Thunderstorm day thunderstormday There are thunder days in a certain area in a year. Just hear more than one thunder in a day or see more than one lightning, even a mine A stormy day. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 37317-2019_English be delivered?Answer: Upon your order, we will start to translate GB/T 37317-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 37317-2019_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 37317-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |