GB/T 36116-2018: Requirements for the control system function of the rural photovoltaic power station cluster
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 36116-2018279 Add to Cart 3 days Requirements for the control system function of the rural photovoltaic power station cluster Valid

Similar standards

GB/T 37658   GB/T 37408   GB/T 33589   GB/T 36117   GB/T 36115   

Basic data

Standard ID: GB/T 36116-2018 (GB/T36116-2018)
Description (Translated English): Requirements for the control system function of the rural photovoltaic power station cluster
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: F12
Classification of International Standard: 27.160
Word Count Estimation: 14,153
Date of Issue: 2018-03-15
Date of Implementation: 2018-10-01
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 36116-2018: Requirements for the control system function of the rural photovoltaic power station cluster


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Requirements for the control system function of the rural photovoltaic power station cluster ICS 27.160 F12 National Standards of People's Republic of China Photovoltaic power plant cluster control system functional requirements Stationcluster Published by.2018-03-15 2018-10-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Administration released Directory Preface III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Basic regulations 1 5 Village and town photovoltaic power station cluster control system architecture 2 6 Photovoltaic power station cluster monitoring master station function configuration 2 7 Photovoltaic power station monitoring terminal function configuration 4 8 Communication 4 Appendix A (Informative Appendix) Cluster Control Architecture for Photovoltaic Power Plant Clusters 6 Appendix B (normative appendix) Table of function configuration of monitoring stations for photovoltaic power stations in towns and villages Appendix C (normative appendix) Performance requirements for cluster monitoring primary station of town photovoltaic power station 8 Appendix D (Normative Appendix) Table of Functions of Monitoring Terminals for Photovoltaic Power Plants in Villages and Towns

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuing agency of this document does not assume responsibility for identifying these patents. This standard is proposed by the China Electricity Council. This standard is under the jurisdiction of the National Microgrid and Distributed Power Grid Standardization Technical Committee (SAC/TC564). This standard was drafted by. China Electric Power Research Institute Co., Ltd., State Grid Zhejiang Electric Power Co., Ltd. Jiaxing Power Supply Company, State Grid Lake North Electric Power Co., Ltd., State Grid Anhui Power Co., Ltd., Tsinghua University, Nanjing Green Energy Research Institute Co., Ltd. The main drafters of this standard. Sheng Wanxing, Ji Yu, Wu Ming, Liu Haitao, Jin Wei, Yu Hui, Dong Guolun, Yan Lingfeng, Hou Yiming, Wu Wenchuan, Yang Chunbo, Hu Shijun, Jiao Zhen, Xu Wei, Chen Qi, Liu Weiliang, Luo Yi, Zheng Nan, Zhang Hao, Xiong Xiong, Ding Baodi, Qiu Xinjie, Ling Song. Photovoltaic power plant cluster control system functional requirements

1 Scope

This standard specifies the technical requirements for the cluster control system architecture, function configuration, and communication of photovoltaic power stations in villages and towns. This standard is applicable to the cluster control system of PV power-saving poverty alleviation power stations in power grids with voltage ratings of 10 kV and below.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 29319 Photovoltaic Power Generation System Access Distribution Network Technical Regulations DL/T 634.5-101 Telecontrol Equipment and Systems Part 5-101. Transmission Protocol Basic Remote Task Supporting Standards DL/T 634.5-104 Telecontrol equipment and systems Part 5-104. Transmission protocols using the standard transmission protocol set IEC 60870-5- 101 network access NB/T 32016 Grid-connected photovoltaic power generation monitoring system specification

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Village photovoltaic power station ruralphotovoltaicpowerstation Photovoltaic power stations with a capacity of no more than 500kW built in rural areas. 3.2 Photovoltaic grid-connected inverter PVinverter The electrical equipment that converts the DC power generated by solar cells into AC power and feeds it into the power grid. 3.3 Point of internet connection For photovoltaic power stations with boost stations, the bus or nodes on the high-pressure side of the booster station; for photovoltaic power stations without a boost station, photovoltaic generation Power station output summary point. 3.4 Village photovoltaic power station cluster ruralphotovoltaicpowerstationcluster Adjoining geographically, and assembled via power distribution lines to multiple photovoltaic power stations at the same 35kV or 110(66)kV substation set. 3.5 Photovoltaic power station cluster control clustercontrolofphotovoltaicpowerstation With the principle of close electrical distance and centralized management and control, the integration and centralized control of multiple PV power plants can be realized.

4 Basic regulations

4.1 The photovoltaic power plant cluster control system in villages and towns should be monitored by photovoltaic power station, town photovoltaic power station cluster monitoring master station and communication system.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 36116-2018_English be delivered?

Answer: Upon your order, we will start to translate GB/T 36116-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 36116-2018_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 36116-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.