GB/T 35428-2024 English PDFUS$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 35428-2024: Requirements of environmental control for hospital negative pressure isolation ward Status: Valid GB/T 35428: Historical versions
Basic dataStandard ID: GB/T 35428-2024 (GB/T35428-2024)Description (Translated English): Requirements of environmental control for hospital negative pressure isolation ward Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: C70 Classification of International Standard: 13.040.35 Word Count Estimation: 10,170 Date of Issue: 2024-09-29 Date of Implementation: 2025-04-01 Older Standard (superseded by this standard): GB/T 35428-2017 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 35428-2024: Requirements of environmental control for hospital negative pressure isolation ward---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Requirements of environmental control for hospital negative pressure isolation ward Environmental control requirements for negative pressure isolation wards in hospitals Requirements of environmental control for hospital negative pressure isolation ward ICS 13.040.35 CCS C 70 National Standard of the People's Republic of China Replaces GB/T 35428-2017 Released on 2024-09-29 2025-04-01 Implementation State Administration for Market Regulation The National Standardization Administration issued Table of ContentsPreface ... Ⅲ 1 Scope ... 1 2 Normative references ... 1 3 Terms and Definitions ... 1 4 Technical requirements ... 2 5 Detection methods ... 4 References ... 5ForewordThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting is required. This document replaces GB/T 35428-2017 "Environmental Control Requirements for Negative Pressure Isolation Wards in Hospitals" and is consistent with GB/T 35428-2017. In addition to structural adjustments and editorial changes, the main technical changes are as follows. Changed the “Scope” (see Chapter 1, Chapter 1 of the.2017 edition); - Changed the definitions of "negative pressure isolation ward", "airborne transmission", "isolation" and "buffer room" (see 3.1, 3.2, 3.3, 3.4, 3.1, 3.2, 3.3, 3.7 of the.2017 edition); The definitions of “clean area”, “contaminated area”, “potentially contaminated area”, “fresh air”, “fresh air volume” and “air change frequency” have been deleted (see 2017 version 3.4, 3.5, 3.6, 3.8, 3.9, 3.10); Changed building layout and isolation requirements, including buffer room access requirements, interlock door closing and opening intervals, and transfer windows. The setting location, etc. (see 4.1, 4.1 of the.2017 edition); The requirements for indoor clear height, internal and external calls and video surveillance, and limiting the range of patient activities have been deleted (see 4.1.8,.2017 edition). 4.1.15, 4.1.16); Changed the requirements for airflow organization and pressure difference control, including the clean area air pressure, pressure difference diagram, etc. (see 4.2,.2017 edition 4.2); Changed the requirements for hygiene and environmental parameters, including average colony count in the air, average colony count on surfaces, ventilation rate, temperature, Temperature, relative humidity, illumination, etc. (see 4.3, 4.6 of the.2017 edition); The requirements for ventilation and air conditioning systems have been changed, including the requirements for standby exhaust fans and their automatic switching, and the distance requirements for exhaust vents (see 4.4, 4.3 of the.2017 edition); The requirements for water supply and drainage have been changed, including the location requirements for vent openings (see 4.5, 4.4 of the.2017 edition); - Changed the requirements for electrical and intelligent systems (see 4.6, 4.5 of the.2017 edition); - Added requirements for medicinal gases (see 4.7); - Changed the test requirements and methods (see Chapter 5, Chapter 5 of the.2017 edition). - Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed and coordinated by the National Technical Committee for Standardization of Clean Rooms and Related Controlled Environments (SAC/TC 319). This document was drafted by. China Electronics System Engineering Second Construction Co., Ltd., Jiangsu Sujing Engineering Construction Co., Ltd., Zhongkai Agricultural Industry School of Engineering, China Electronics Engineering Design Institute Co., Ltd., Shenzhen Yaerdian Environmental Technology Co., Ltd., and the First Medical College of PLA General Hospital Center, Peking University Third Hospital, PLA Air Force Specialty Medical Center, Beijing Ditan Hospital Affiliated to Capital Medical University, China Standardization Association, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Institute of Chemical Defense, Academy of Military Sciences, Peking University First Hospital, Henan Traditional Chinese Medicine The First Affiliated Hospital of the University of Science and Technology, the Institute of Medical Support Technology, Institute of Systems Engineering, Academy of Military Sciences, China Academy of Building Research Co., Ltd., Wuhan University People's Hospital, Peking University Stomatological Hospital, China Electronics Precision Electronic Engineering Co., Ltd., Shenzhen Tiansuo Metrology and Testing Co., Ltd. Beijing Dyna Experimental Technology Co., Ltd., Shanghai Indoor Environment Purification Industry Association, Beijing North Tianyu Medical Building Technology Co., Ltd. Suzhou Xingya Purification Engineering Co., Ltd., Beijing Songcheng Technology Co., Ltd., Suzhou Zhongwei Baojia Purification Technology Co., Ltd., Jiangsu Nuoyou Air Purification Equipment Co., Ltd., Respiratory Research Institute Biosafety Technology (Guangzhou) Co., Ltd., Zhengzhou Shengma Obstetrics and Gynecology Hospital Co., Ltd., Zhengyu Hengxin Group Co., Ltd. and HuiTe Science and Technology Co., Ltd. The main drafters of this document are. Cao Jingui, Sun Weijie, Yang Ziqiang, Qi Jiancheng, Ding Lixing, Liu Shuxing, Yang Xiaobing, Pan Hongxing, Shi Wenting, Yang Yang, Guo Li, He Li, Guo Bacui, Li Minghui, Mu Li, Wang Li, Cao Guoqing, Lu Yang, Hao Yinbo, Cao Hai, Wang Fang, Zhou Hengjin, Mapusong, Lin Huiqing, Shi Xia, Lei Jie, Xi Xiaopeng, Chen Siyuan, Zhang Zhaohong, Shi Jiancheng, Yuan Youhua, Zhang Hua, Chen Zhen, Bai Bing, Huang Xiaofei, Zhou Rong. The previous versions of this document and the documents it replaces are as follows. First published in.2017 as GB/T 35428-2017; - This is the first revision. - Environmental control requirements for negative pressure isolation wards in hospitals1 ScopeThis document specifies the negative pressure isolation wards used by hospitals to isolate and treat patients or suspected patients with infectious diseases that may be transmitted through the air. Technical requirements for environmental control. This document applies to negative pressure isolation wards in hospitals.2 Normative referencesThe contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies. in this document. GB 15982 Hospital Disinfection and Hygiene Standard GB/T 25915.3 Clean rooms and related controlled environments Part 3.Test methods GB/T 36066 Analysis and application of testing technology for clean rooms and related controlled environments GB 50346 Technical Specification for Biosafety Laboratory Buildings GB 50591 Clean room construction and acceptance specification GB 50686 Code for Construction and Acceptance of Infectious Disease Hospitals3 Terms and definitionsThe following terms and definitions apply to this document. 3.1 negative pressure isolation ward It has places and facilities for medical treatment and nursing, meets the basic needs of patients, and uses technical means to reduce the static air pressure in the room. The static air pressure in the surrounding adjacent areas is used to prevent the air containing pathogenic microorganisms from spreading outwards. Note. The area consisting of multiple negative pressure isolation wards and patient passages, medical staff passages and related buffer rooms is called a negative pressure isolation ward. 3.2 airborne transmission The virus is transmitted by droplet nuclei (≤5 μm) suspended in the air, which can be transmitted over long distances ( >1 m) and remain infectious for a long time. Caused by the spread. [Source. WS/T 311-2023, 3.5] 3.3 Isolation Measures that use various methods and technologies to prevent the spread of pathogens from patients, carriers and places to others. [Source. WS/T 311-2023, 3.9] 3.4 Buffer room There are doors on both sides between the clean area and the potential contaminated area, and between the potential contaminated area and the contaminated area, and the doors on both sides do not open at the same time Transition room. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 35428-2024_English be delivered?Answer: Upon your order, we will start to translate GB/T 35428-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 35428-2024_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 35428-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 35428-2024?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 35428-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |