GB/T 33982-2017: Technical specification for grid connection protection of distributed resources
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 33982-2017199 Add to Cart 3 days Technical specification for grid connection protection of distributed resources Valid

Similar standards

GB/T 38953   GB/T 37155.2   GB/T 19826   GB/T 45648.1   GB/T 45648.2   

Basic data

Standard ID: GB/T 33982-2017 (GB/T33982-2017)
Description (Translated English): Technical specification for grid connection protection of distributed resources
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K45
Classification of International Standard: 29.240.01
Word Count Estimation: 10,126
Date of Issue: 2017-07-12
Date of Implementation: 2018-02-01
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 33982-2017: Technical specification for grid connection protection of distributed resources

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical specification for grid connection protection of distributed resources ICS 29.240.01 K45 National Standards of People's Republic of China Distributed power grid interconnection protection technical specifications 2017-07-12 Posted 2018-02-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 General 2 5 protection configuration and technical requirements 2 5.1 distributed power access by the green 10kV (6kV) ~ 35kV distribution network 2 5.2 Distributed Power T access 10kV (6kV) ~ 35kV distribution network 3 5.3 Distributed Power Switchgear (power distribution room, box change) access 10kV (6kV) ~ 35kV distribution network 4 5.4 Distributed power access 380V distribution network protection configuration and technical requirements 4 Appendix A (informative) Distributed power access system typical wiring diagram 5

Foreword

This standard was drafted in accordance with the provisions given in GB/T 1.1-2009. This standard proposed by the China Electrical Equipment Industry Association. This standard by the National Measurement Relay and Protection Equipment Standardization Technical Committee (SAC/TC154) centralized. This standard was drafted unit. China Electric Power Research Institute, the State Power Dispatching Control Center, State Grid Zhejiang Power Company, Xuchang Cape Electric Gas Research Institute, State Grid Jiangsu Provincial Power Company, Xu Ji Group Co., Ltd., Xuchang Cape Detection Technology Co., Ltd., Nanjing NARI insurance Electric have Co., Ltd., Beijing Sifang Automation Co., Ltd., Xu Ji Electric Co., Ltd., State Grid Shandong Power Company, State Grid Hunan Province Power Company, Guodian Nanjing Automation Co., Ltd., Beijing Ziguang Measurement and Control Co., Ltd., Evergreen Shenzhen Rui Bao Automation Co., Ltd., plot Electronics Co., Ltd., Eastern Electronics Co., Ltd., State Grid Electric Power Research Institute, Hebei Beheng Electric Technology Co., Ltd., Jiangsu gold Technology Co., Ltd., ABB (China) Co., Ltd., State Power NARI Technology Co., Ltd., Schneider Electric China Co., Ltd., Jicheng Energy Co., Ltd., Baoding and easy to France Electric Technology Co., Ltd., Nanjing due Taylor Electric Co., Ltd., Beijing Tianneng following insurance power Technology Co., Ltd. The main drafters of this standard. Yang Guosheng, Wang Xiaoyang, Liu Yu, Wang Delin, Zhou Zexin, Qiu Yuetao, Li Zhiyong, Guan Yibin, Li Ruisheng, Wang Wenhuan, Li Wei, Wang Lei Ming, Huang Haosheng, Guo Baofu, Xu Guangfu, Sun Thunder, Xu Jian, Wang Anning, Zhu Weijun, Li Yuping, Li Wei Fan, Zhao Shuo, Quan Xianjun, Li Weiliang, Tian Jianjun, Chen Xiaoyu, to dry Liang, Tang Chenghong, Yang Lizhi, Yuan Wenguang, Li Aifeng, Wan Shangjun, Chai Jingbo. Distributed power grid interconnection protection technical specifications

1 Scope

This standard specifies the distributed power access 35kV and below the protection of the power grid should meet the technical requirements. This standard applies to the configuration and setting of distributed power supply side protection when access to the 35kV and below voltage level power grid.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 14285 relay protection and safety automatic device technical regulations GB/T 19939 photovoltaic system and network requirements GB/T 20046 Photovoltaic (PV) system grid interface characteristics GB/T 29319 photovoltaic power generation system access distribution network technical requirements GB 50054 low-voltage power distribution design specifications DL/T 584 3kV ~ 110kV power grid protection device operation setting procedures NB/T 32015 Distributed Power Distribution Network Technical Requirements

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Distributed power distributedresources; DR In the user's premises or nearby construction and installation, operation mode to user-side spontaneous use-based, excess power access, and in the distribution network Balanced regulation of the power generation facilities or energy output of the power integrated cascade use of multi-supply facilities. 3.2 Converter converter Electrical equipment for converting electrical power into one or more forms of electrical power suitable for use by the electrical grid or user. Including rectification Inverter, AC converter and DC converter. 3.3 Converter Type Power converter-typepowersupply All or part of the power connected to the grid through the converter. 3.4 Rotary motor type Distributed power rotating-machine-typeDR Distributed power generated by rotating electrical machines. 3.5 Pointofinterconnection For the distributed power supply with booster station, the network connection point is the busbar or node on the high-voltage side of the booster station for distributed power supply; for the booster station without distribution
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 33982-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 33982-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 33982-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 33982-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries