GB/T 33865-2017 English PDFUS$279.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 33865-2017: Calibration method for photosynthetic active radiometer Status: Valid
Basic dataStandard ID: GB/T 33865-2017 (GB/T33865-2017)Description (Translated English): Calibration method for photosynthetic active radiometer Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: A47 Classification of International Standard: 07.060 Word Count Estimation: 14,119 Date of Issue: 2017-07-12 Date of Implementation: 2018-02-01 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China GB/T 33865-2017: Calibration method for photosynthetic active radiometer---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Calibration method for photosynthetic active radiometer ICS 07.060 A47 National Standards of People's Republic of China Calibration method of photosynthetically active radiation table 2017-07-12 released 2018-02-01 Implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface I 1 Scope 1 2 terms and definitions3 Calibration conditions 1 4 calibration method 25 Uncertainty assessment of calibration results6 calibration results 3 7 re - school time interval 3 Appendix A (Normative Appendix) Spectral Radiometer Specifications 4 Appendix B (normative) Spectral radiometer method 5 Appendix C (informative) Evaluation of Uncertainty in Calibration Results of Photosynthetically Effective Radiation Table 7 Reference 10ForewordThis standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed by the China Meteorological Administration. This standard is nationalized by the National Standardization Technical Committee for Meteorological Instruments and Observation Methods (SAC/TC507). The drafting unit of this standard. National Meteorological Metering Station, Yunnan Province, atmospheric detection and security center, Jiangsu Province Radio Science Research Institute Co., Ltd. The main drafters of this standard. Yang Yun, Quan Jimei, Ding Lei, Chong Wei, Lin Bing, Wang Yunkun, Hu Mei, Wang Xin, Zhu Ya, Xu Yigang. Calibration method of photosynthetically active radiation table1 ScopeThis standard specifies the calibration conditions for the photosynthetically active radiation table, the calibration method, and the uncertainty of the calibration results. This standard is applicable to the calibration of the sensitivity of the hemisphere to the photosynthetically active radiation table.2 terms and definitionsThe following terms and definitions apply to this document. 2.1 Photosynthetic active radiation table photosyntheticactiveradiometer Hemispherical to the photosynthetic effective radiation table hemisphericalphotosyntheticactiveradiometer Measure the radiant table of the total solar radiation from 400 nm to 700 nm received from the upper 2π solid angle of the given plane.3 calibration conditions3.1 Environmental conditions 3.1.1 around the open, the instrument sensor surface above no obstacles. 3.1.2 sunny sky, the sun height angle of not less than 30 °, should be in place 10.00 to 14.00 between. 3.1.3 air temperature in the range of 10 ℃ ~ 30 ℃, the relative humidity of not more than 80%, wind speed is not greater than 5m/s. 3.2 standard and ancillary equipment 3.2.1 Standard Photosynthetic Effective Radiation Table Should meet the following requirements. a) The uncertainty should not be greater than 6%; b) cosine response error (zenith angle 0 ° ~ 80 °) should not be greater than 10%; c) azimuth response error (zenith angle 0 ° ~ 70 °) should not be greater than 5%; d) the temperature error should not be greater than 0.3%/℃; e) Stability should not be greater than 3%. 3.2.2 digital instrumentation 0.05, resolution 1μV. 3.2.3 Environmental measuring instruments Technical indicators in Table 1. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 33865-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 33865-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 33865-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 33865-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |