GB/T 33420-2016 English PDFUS$159.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 33420-2016: Evaluation standard of biological for moist heat sterilization processes Status: Valid
Basic dataStandard ID: GB/T 33420-2016 (GB/T33420-2016)Description (Translated English): Evaluation standard of biological for moist heat sterilization processes Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: C50 Word Count Estimation: 8,824 Date of Issue: 2016-12-30 Date of Implementation: 2017-07-01 Quoted Standard: GB 18281.1; GB/T 24628; ���������淶(2002��)������ Regulation (derived from): National Standard Notice No.27 of 2016 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the test method for the pressure steam sterilization biological indicator. This standard applies to the verification of pressure steam sterilization biological indicators. GB/T 33420-2016: Evaluation standard of biological for moist heat sterilization processes---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Evaluation standard of biological for moist heat sterilization processes ICS 11.080 C50 National Standards of People's Republic of China Test method for biological indicators of pressure steam sterilization 2016-12-30 release 2017-07-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released ForewordThis standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed by the National Health and Family Planning Commission of the People's Republic of China. The drafting of this standard. China Center for Disease Control and Prevention Environmental and Health Related Products Safety, the Chinese People's Liberation Army disease prevention and control Ltd., Xinhua Medical Devices Co., Ltd., China Academy of Medical Sciences Union Hospital, Shandong Lierkang disinfection Technology Co., Ltd., 3M China Limited, Hangzhou Ruowao Fu Import & Export Co., Ltd. The main drafters of this standard. Zhang flow, Zhang Jian, Yao Chuanshui, Zhang Qing, Wang Yanyan, Shen Jin, Huang Jingxiong, Zhu Xiaoming, Zhu Hanquan, Ma Ling, Ban Haiqun. Test method for biological indicators of pressure steam sterilization1 ScopeThis standard specifies the test method for the pressure steam sterilization biological indicator. This standard applies to the verification of pressure steam sterilization biological indicators.2 normative reference documentsThe following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. Health care products - Sterilization - Biological indicators - Part 1. General rules GB 18281.1 GB/T 24628 Sterilization products for medical and health products - Test equipment for biological and chemical indicators Disinfection technical specifications (2002 edition) Ministry of Health3 terms and definitionsThe following terms and definitions apply to this document. 3.1 Biological indicator biologicalindicator; BI The specific sterilization procedures under the specified conditions have a certain resistance, and installed in the inner packaging available in the bacteria carrier. 3.2 Carrier carrier Test the support of microbes. 3.3 Survival time; Exposed to the bactericidal factor under specified conditions, the maximum time for the microorganisms to survive in the biological indicator of the test. 3.4 Kill time kiling time; Determination of biological indicator resistance, the test sample after the role of sterilization factor, the most sterile growth of the shortest duration of action. 3.5 D value Dvalue The time required to kill 90% of the total number of specific test microorganisms under the set exposure conditions. 3.6 Survival curve survivorcurve Under the action of immobilized sterilization factors, the association between the survival of microbes and exposure changes. 3.7 Biological indicator resistance tester biologicalindicatorevaluatorresistometer Produce a limited amount of sterilization process under the conditions specified in the combination of physical and chemical changes to measure the resistance of the special equipment. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 33420-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 33420-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 33420-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 33420-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |