Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 33292-2016 English PDF

US$359.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 33292-2016: Metal hydride hydrogen storage system for fuel cells backup power
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 33292-2016359 Add to Cart 4 days Metal hydride hydrogen storage system for fuel cells backup power Valid

Similar standards

GB/T 34131   GB/T 34133   GB/T 34120   GB/T 45539   

Basic data

Standard ID: GB/T 33292-2016 (GB/T33292-2016)
Description (Translated English): Metal hydride hydrogen storage system for fuel cells backup power
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: F19
Classification of International Standard: 27.180
Word Count Estimation: 18,191
Date of Issue: 2016-12-13
Date of Implementation: 2017-07-01
Regulation (derived from): National Standard Notice No.247 of 2016
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 33292-2016: Metal hydride hydrogen storage system for fuel cells backup power

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Metal hydride hydrogen storage system for fuel cells backup power ICS 27.180 F19 National Standards of People's Republic of China Metal hydride hydrogen storage systems for fuel cell backup power supplies 2016-12-13 released 2017-07-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface III 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1 4 named 2 Technical requirements 2 5.1 Hydrogen storage system for metal hydride 2 5.2 Single device 3 5.3 Piping and accessories 4 5.4 Safety measures 5 6 Test and Detection 5 6.1 General requirements 5 6.2 Test environmental conditions 5 6.3 Dehydrogenation performance test 5 6.4 Hydrogenation performance test 6 6.5 cycle charge/discharge life test 6 6.6 Salt spray test 7 6.7 Air tightness test 7 6.8 Vibration test 7 6.9 Thermal cycling test 8 6.10 Detection 9 7 logo 10 7.1 General requirements 10 7.2 Logo Contents 10 7.3 Box illustration 10 8 product random file 10 8.1 Transportation and installation requirements 8.2 Product quality documents 10 8.3 User's Manual 11 8.4 Installation and Maintenance Manual 11 9 Packaging 11 Appendix A (Normative Appendix) Fuel Cell Backup Power Supply Metal Hydride Hydrogen Storage System Batch Inspection Quality Certificate 12

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed by the National Hydrogen Standardization Technical Committee (SAC/TC309). The drafting of this standard. Beijing Nonferrous Metals Research Institute, China Standardization Research Institute, China Electronic Engineering Design Institute, Tsinghua University, Zhejiang Jiang University, Tongji University, China Information and Communication Research Institute, Beijing Jiu'an hydrogen energy Technology Co., Ltd. The main drafters of this standard. Lei Yang, Jiang Lijun, Wang Shumao, Li Yan, Liao Guocheng, Mao Zongqiang, Gu Chaohua, Chen Lixin, Zhang Cunman, Qi Shuguang, Zhang lifang Metal hydride hydrogen storage systems for fuel cell backup power supplies

1 Scope

This standard specifies the term and definition, designation, technical requirements, test and inspection of metal hydride hydrogen storage systems for fuel cell backup power supplies. Measuring, marking and packaging. This standard applies to industrial, commercial fixed fuel cell backup power supply with metal hydride hydrogen storage system. This standard applies to the working pressure does not exceed 4MPa, the working environment temperature of not less than -40 ℃ and not higher than 45 ℃ fuel cell equipment Metal hydride hydrogen storage system for power supply.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 191 packaging and storage icon GB/T 2423.10 Environmental testing for electric and electronic products - Part 2. Test methods - Test Fc. Vibration (sinusoidal) GB/T 2423.17 Environmental testing for electric and electronic products - Part 2. Test methods Test Ka. Salt mist GB/T 2423.23 Environmental testing for electric and electronic products - Part 2. Test methods - Test Q. Seals GB/T 3634.1 Hydrogen - Part 1. Industrial hydrogen GB/T 3634.2 Hydrogen - Part 2. Hydrogen, high - purity hydrogen and ultrapure hydrogen GB/T 3873 General specification for packaging of communication equipment products Safety specification for hydrogen use GB/T 13306 signs GB/T 13310 electric vibration table GB 15382 General technical requirements for cylinder valves Hydrogen, Hydrogen and Hydrogen Systems - Terminology GB/T GB/T 29729 Basic requirements for hydrogen system safety GB 50177 Hydrogen station design specification TSG21 fixed pressure vessel safety technical supervision procedures ISO 16111 Mobile Hydrogen Storage Device Metal Hydride Reversible Absorption Hydrogen (Transportablegasstoragedevices- Hydrogenabsorbedinreversiblemetalhydride)

3 terms and definitions

GB/T 24499 Definitions and the following terms and definitions apply to this document. 3.1 Metal hydride Metal or alloy and hydrogen combined with the formation of reversible absorption and release of hydrogen solid materials. 3.2 Maximum temperature rise pressure maximumdevelopedpressure; MDP Metal hydride hydrogen storage system after hydrogen saturation, at the highest temperature to reach equilibrium when the maximum gas pressure (gauge pressure).
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 33292-2016_English be delivered?

Answer: Upon your order, we will start to translate GB/T 33292-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 33292-2016_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 33292-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.