GB/T 32483.2-2021 PDF EnglishUS$205.00 · In stock · Download in 9 seconds
GB/T 32483.2-2021: Energy performance of lamp controlgear - Part 2: Controlgear for high intensity discharge lamps(excluding fluorescent lamps) - Method of measurement to determine the efficiency of controlgear Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
Similar standardsGB/T 32483.2-2021: Energy performance of lamp controlgear - Part 2: Controlgear for high intensity discharge lamps(excluding fluorescent lamps) - Method of measurement to determine the efficiency of controlgear---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT32483.2-2021 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.140.99 CCS K 74 GB/T 32483.2-2021 / IEC 62442-2:2018 Energy Performance of Lamp Controlgear – Part 2: Controlgear for High Intensity Discharge Lamps (Excluding Fluorescent Lamps) – Method of Measurement to Determine the Efficiency of Controlgear (IEC 62442-2:2018, IDT) ISSUED ON: NOVEMBER 26, 2021 IMPLEMENTED ON: JUNE 01, 2022 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of ContentsForeword ... 3 Introduction ... 4 1 Scope ... 5 2 Normative References ... 5 3 Terms and Definitions ... 6 4 General ... 8 5 Method of Measurement of the Input Power and Calculation of the Efficiency of Controlgear for High Intensity Discharge Lamps ... 10 Bibliography ... 15ForewordThis document was drafted as per the rules specified in GB/T 1.1-2020 Directives for Standardization – Part 1: Rules for the Structure and Drafting of Standardizing Documents. This Document is Part 2 of GB/T 32483 Energy Performance of Lamp Controlgear. GB/T 32483 has published the following parts: --- Part 1: Controlgear for Fluorescent Lamps - Method of Measurement to Determine the Total Input Power of Controlgear Circuits and the Efficiency of the Controlgear; --- Part 2: Controlgear for High Intensity Discharge Lamps (Excluding Fluorescent Lamps) -Method of Measurement to Determine the Efficiency of Controlgear; --- Part 3: Controlgear for Halogen Lamps and LED Modules-Method of Measurement to Determine the Efficiency of the Controlgear. This Document used translation method to equivalently adopt IEC 62442-2:2018 Energy Performance of Lamp Controlgear – Part 2: Controlgear for High Intensity Discharge Lamps (Excluding Fluorescent Lamps) – Method of Measurement to Determine the Efficiency of Controlgear. Please note some contents of this Document may involve patents. The issuing agency of this Document shall not assume the responsibility to identify these patents. This Document was proposed by China National Light Industry Council. This Document shall be under the jurisdiction of National Technical Committee on Electrical Lighting of Standardization Administration of China (SAC/TC 224). Drafting organization of this Document: Guangdong Zhongliang Testing Co., Ltd.; National Lighting Test Center on Electric Light Source (Beijing); and Anhui Joyo Electric Co., Ltd. Chief drafting staffs of this Document: Cai Zhe, Wang Yousuo, Xie Runqing, and Zhang Bo. Energy Performance of Lamp Controlgear – Part 2: Controlgear for High Intensity Discharge Lamps (Excluding Fluorescent Lamps) – Method of Measurement to Determine the Efficiency of Controlgear1 ScopeThis Document defines a measurement method of the power losses of electromagnetic controlgear, the total input power and the standby power of electronic controlgear for high intensity discharged lamps (excluding fluorescent lamps). A calculation method of the efficiency of controlgear for high intensity discharged lamp(s) is also defined. This Document assumes that the controlgear are designed for use on DC supplies up to 1 000 V and/or AC supplies up to 1 000 V at 50 Hz or 60 Hz. This Document applies to electrical controlgear-lamp circuits comprised solely of the controlgear and of the lamp(s). NOTE: Requirements for testing individual controlgear during production are not included. This Document specifies the measurement method for the total input power, the standby power and the calculation method of the lamp controlgear efficiency for all controlgear sold for domestic and normal commercial purposes operating with high intensity discharge lamps. This Document does not apply to: --- controlgear which form an integral part of lamps; --- controlgear circuits with capacitors connected in series; --- controllable electromagnetic controlgear.2 Normative ReferencesThe provisions in following documents become the essential provisions of this Document through reference in this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this Document. IEC 61347-1:2015 Lamp Controlgear – Part 1: General and Safety Requirements ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. |