Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 31886.2-2015 PDF English

US$175.00 · In stock · Download in 9 seconds
GB/T 31886.2-2015: Test Method about the Influence of Gaseous Contaminants in Reaction Gas on the Performance of Proton Exchange Membrane Fuel Cell - Part 2: Gaseous Contaminants in Hydrogen
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
GB/T 31886.2-2015175 Add to Cart Auto, 9 seconds. Test Method about the Influence of Gaseous Contaminants in Reaction Gas on the Performance of Proton Exchange Membrane Fuel Cell - Part 2: Gaseous Contaminants in Hydrogen Valid

Similar standards

GB 31241   GB/T 31886.1   GB/T 31037.2   GB/T 45565   

GB/T 31886.2-2015: Test Method about the Influence of Gaseous Contaminants in Reaction Gas on the Performance of Proton Exchange Membrane Fuel Cell - Part 2: Gaseous Contaminants in Hydrogen



---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT31886.2-2015
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 27.070 K 82 Test Method about the Influence of Gaseous Contaminants in Reaction Gas on the Performance of Proton Exchange Membrane Fuel Cell – Part 2. Gaseous Contaminants in Hydrogen Issued on: SEPTEMBER 11, 2015 Implemented on: APRIL 01, 2016 Issued by. General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of PRC.

Table of Contents

Foreword . 3 1 Scope .. 4 2 Normative References . 4 3 Terms and Definitions . 5 4 Test Bench and Instrumentation Requirements .. 5 5 Pre-Test Preparation .. 7 6 Test Methods .. 9 7 Test Report . 14 Appendix A (Informative) Test Report . 15 Test Method about the Influence of Gaseous Contaminants in Reaction Gas on the Performance of Proton Exchange Membrane Fuel Cell – Part 2. Gaseous Contaminants in Hydrogen

1 Scope

This Standard specifies the terms and definitions, test bench and instrumentation requirements, pre-test preparation, test method and test report relevant to the test method about the influence of carbon monoxide (CO) gaseous contaminants in hydrogen on the performance of proton exchange membrane fuel cell. This Standard is applicable to the proton exchange membrane fuel cell single cell (hereinafter referred to as “fuel cell”). The volume fraction of gaseous contaminant in hydrogen applicable to the test method described in this Standard is no less than 1µL/L.

2 Normative References

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document. GB 3095-2012 Ambient Air Quality Standard GB/T 5274 Gas Analysis - Preparation of Calibration Gas Mixture - Gravimetric Method GB/T 5275.10 Gas Analysis - Preparation of Calibration Gas Mixtures Using Dynamic Volumetric Methods - Part 10. Permeation Method GB/T 3634.2-2011 Hydrogen - Part 2. Pure Hydrogen, High Pure Hydrogen and Ultrapure Hydrogen GB/T 20042.1-2005 Proton Exchange Membrane Fuel Cell – Terminology GB/T 20042.5 Proton Exchange Membrane Fuel Cell – Part 5. Test Method for Membrane Electrode Assembly GB/T 28816-2012 Fuel Cell - Terminology

3 Terms and Definitions

The following terms and definitions and those ones stipulated in GB/T 20042.1-2005 and GB/T 28816-2012 are applicable to this document. 3.1 Clean air The air that contains various contaminants whose concentrations do not exceed the annual average primary concentration limit specified in 4.2 of GB 3095-2012. NOTE 1. the definition of clean air in this Standard is only for its use as a fuel cell oxidant. NOTE 2. the recommended clean air for this Standard is a formulated gas with oxygen concentration of 21%, balance gas of nitrogen. 3.2 Gaseous contaminants in hydrogen gas Other gases contained in the fuel hydrogen. The applicable gaseous contaminant in this Standard is CO. 3.3 Fuel cell poisoning The phenomenon of voltage attenuation of fuel cell caused by the gaseous contaminants in the reaction gas. NOTE. all “poisoning” in this Standard refers to “fuel cell poisoning”. 3.4 Poisoning operation The process of operating that the fuel cell adopts the reaction gas containing the gaseous contaminants. NOTE 1. the definition of poisoning in this Standard is only for fuel cell. NOTE 2. the contaminants indicate the gas components that may cause the poisoning of the fuel cell.

4 Test Bench and Instrumentation Requirements

4.1 Test bench of fuel cell According to the provisions of 6.1 sample preparation and 6.2 test instrument and device in GB/T 20042.5-2009, the basic information of fuel cell under test is provided as follows. --- The effective area of the sample membrane electrode is 50cm2; the surrounding area outside the effective area shall be sealed; --- The flow filed plate adopts pure graphite plate with a serpentine flow filed; --- The collector plate adopts the silver or gold coated stainless steel plate; --- Fuel cell manufacturer provides cathode anode catalytic layer platinum load. 5.2 Determination of test conditions According to the atmospheric pressure test method specified in 6.7 of GB/T 20042.5- 2009, the following test conditions shall be determined. --- The type of the used contaminants (X) and target contaminant volume fraction (cXd); --- The operating temperature of fuel cell. 75°C; --- The test current densities are. 200 mA/cm2, 500 mA/cm2 and 800 mA/cm2; --- The lowest voltage for the fuel cell operating (Umin). 0.3V; --- The longest poisoning time (tdmax). 10h; --- The fuel gas outlet back pressure is 0MPa, stoichiometric ratio is 1.2; relative humidity is 100%; --- The oxidant outlet back pressure is 0MPa, stoichiometric ratio is 2.5; relative humidity is 100%; --- The continuous sampling interval for each parameter during the test shall not exceed 1min; thereof, the continuous sampling interval of voltage and current shall not exceed 10s. 5.3 Preparation of reaction gas Pure hydrogen. take the hydrogen, the quality of which shall be above that required by GB/T 3634.2-2011 as the pure hydrogen source for test. Clean air of oxidant. prepare enough clean air as the air source required by the test. Gaseous contaminant of hydrogen before dilution. according to the provisions of GB/T 5274 and GB/T 5275.10, prepare the standard and enough gaseous contaminant of Where. Qa1 – pure hydrogen intake flow on steady state phase; Q’a1 – hydrogen with contaminant intake flow before dilution; Qa – total air intake flow; d – dilution ration of hydrogen with contaminant. 6.2.3.2 End of poisoning phase When the fuel cell is operated under poisoning conditions to reach one of the following conditions, the poisoning test is terminated; record the test end time to be tc. The end conditions are as follows. a) Reach the fuel cell poison voltage platform area and continue to operate in the voltage platform area for more than 60min; the maximum fluctuation range of the fuel cell voltage in the area doesn’t exceed ±15mV; the average difference of voltage within any 2min shall not exceed 5mV; b) The fuel cell voltage reaches the minimum operating voltage (Umin) of 0.3V; c) The fuel cell is operated to the maximum poisoning time (tdmax) of 10h. 6.2.4 Recovery phase After the completion of the anti-poisoning test, switch the fuel hydrogen into pure hydrogen to continue the test for 5h; recover the verification against the fuel cell (during such switching process, the fuel cell mustn’t be unloaded or shutdown). 6.3 Data processing 6.3.1 General The test in this Standard is performed under constant current; when judging the fuel cell performance before and after the poisoning, the voltage change shall be taken as the reference basis. According to the data of this test, the average voltage on steady state phase, average voltage after poisoning, average poisoning time, and attenuation amplitude can be calculated. 6.3.2 Steady state performance (Uw) The arithmetic mean value of the voltage of the fuel cell sample i in the steady state operating phase shall be calculated as per the Formula (4); it is used to characterize ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of GB/T 31886.2-2015 be delivered?Answer: The full copy PDF of English version of GB/T 31886.2-2015 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 31886.2-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 31886.2-2015_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 31886.2-2015 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of GB/T 31886.2-2015?

A step-by-step guide to download PDF of GB/T 31886.2-2015_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 31886.2-2015".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9