GB/T 31141-2014 English PDFUS$279.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 31141-2014: Test method of bistable solenoid valve for household and similar use Status: Valid
Basic dataStandard ID: GB/T 31141-2014 (GB/T31141-2014)Description (Translated English): Test method of bistable solenoid valve for household and similar use Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K32 Classification of International Standard: 97.120 Word Count Estimation: 12,112 Date of Issue: 9/3/2014 Date of Implementation: 4/1/2015 Quoted Standard: GB 4706.1-2005; GB/T 2423.2; GB/T 2423.17 Regulation (derived from): People's Republic of China Announcement of Newly Approved National Standards No. 21 of 2014 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Standard specifies the household and similar purposes bistable solenoid valve (hereinafter referred to as electromagnetic valve) of the terms and definitions, common test methods. This Standard applies to R600a, R134a or similar thermodynamic propert GB/T 31141-2014: Test method of bistable solenoid valve for household and similar use---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Test method of bistable bolenoid valve for household and similar use ICS 97.120 K32 National Standards of People's Republic of China Household and similar bistable solenoid valve Universal Detection Issued on. 2014-09-03 2015-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsPreface Ⅰ Introduction Ⅱ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Environmental test and measurement equipment in claim 2 5 Detection 2 5.1 Leakage Test 2 5.2 the maximum operating pressure differential test 3 5.3 interference voltage 3 5.4 tightness test 3 5.5 Flow Test 5 5.6 Cleanliness Test 5 5.7 Test the water content of 5 5.8 Noise Test 5 5.9 winding temperature test 5 5.10 low temperature test 6 5.11 6 temperature test 5.12 resistant to temperature changes Test 6 Corrosion-resistant 6 5.13 5.14 Life Test 6 5.15 hydraulic strength test 7 5.16 7 breaking strength test 5.17 Insulation Resistance Test 7 5.18 electric strength test 7ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Standardization Technical Committee household automatic control (SAC/TC212) centralized. This standard was drafted. China Electric Apparatus Research Institute Co., Ltd., Zhejiang spent three Refrigeration Group Co., Ltd. Zhejiang shield the artificial environment Co., Ltd., Ningbo City, North Lun Haibo Precision Machinery Manufacturing Co., Ltd. Ningbo Ou Electrical know, there is a source of electrical Kang Limited, Hisense Kelon Electrical Holdings Company Limited, Jiangsu Changheng Group automatic controller Ltd., Wuxi Little Swan Co., Ltd., Granville Kay Detection Technology Limited. Drafters of this standard. Chen Yuzhong, Wang Xiangrong, hole Rui Xun, He Dingfang, thanks to Long Ke, Li Huanbin, Xing Chen, Du Li, Ji Xuenong, Chen Bin, Qian Feng.IntroductionThis standard is based on the development of household and similar bistable solenoid valve R & D and production requirements for household and similar purposes bistable The basic standard detection methods state solenoid valve products. Bistable solenoid valve is a refrigerator refrigeration system for controlling fluid flow of refrigerant and off Important parts of the switch. Energy saving refrigeration machine is more commonly used key components, its performance directly affects the relative performance of the machine. General detection methods covered by this standard bistable solenoid valve, through the standard indicators of the performance component testing methods, such independence Li parts can be unified product testing, product certification to promote the unity of the supervision and quality control methods, in line with our actual production, Help standardize and improve the quality of the production and testing. Household and similar bistable solenoid valve Universal Detection1 ScopeThis standard specifies the household and similar bistable solenoid valve (hereinafter referred to as solenoid valve) terms and definitions, general test methods. This standard applies to R600a, R134a or similar thermodynamic properties of the refrigerant, the valve orifice diameter of not more than 1.0mm refrigeration system electricity General Performance Test solenoid valves.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 4706.1-2005 household and similar electrical appliances - Safety - Part 1. General requirements (IEC 60335-1.2004, IDT) GB/T 2423.2 Environmental testing for electric and electronic products Part 2. Test methods Test B. Dry heat (GB/T 2423.2- 2008, IEC 60068-2-2.2007, IDT) GB/T 2423.17 Environmental testing for electric and electronic products Part 2. Test methods - Test Ka. Salt Spray (GB/T 2423.17- 2008, IEC 60068-2-11. 1981, IDT)3 Terms and DefinitionsThe following terms and definitions apply to this document. 3.1 Bistable solenoid valve bistablesolenoidvalve By direction of the positive and negative pulse current control input coil iron core control station, thereby controlling the flow of refrigerant or switching off the electrical lead Magnetic valves, each of which has two iron core activity stations, in the case of loss of power to maintain the original station. 3.2 Drive pulse drivepulse For driving the electromagnetic valve action of the pulsation waveform power. As shown in Figure 1. Figure 1 a schematic view of the driving waveforms ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 31141-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 31141-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 31141-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 31141-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |