GB/T 29910.4-2013: Industrial communication networks -- Fieldbus specifications -- Type 20 HART specification -- Part 4: Application layer protocol specification
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 29910.4-20131194 Add to Cart 3 days Industrial communication networks -- Fieldbus specifications -- Type 20 HART specification -- Part 4: Application layer protocol specification Valid

Similar standards

GB/T 33008.1   GB/T 33009.1   GB/T 33009.2   GB/T 29910.3   GB/T 29910.5   GB/T 29910.2   

Basic data

Standard ID: GB/T 29910.4-2013 (GB/T29910.4-2013)
Description (Translated English): Industrial communication networks -- Fieldbus specifications -- Type 20 HART specification -- Part 4: Application layer protocol specification
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: N10
Classification of International Standard: 25.040
Word Count Estimation: 60,663
Quoted Standard: GB/T 29910.3-2013; GB/T 29910.5-2013; IEC 60559; IEC/TR 61158-1; ISO/IEC 7498-1; ISO/IEC 8824-1; ISO/IEC 8825-1; ISO/IEC 8859-1; ISO/IEC 9545
Adopted Standard: IEC 61158-6-20: 2010, IDT
Regulation (derived from): National Standards Bulletin No. 25 of 2013
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the basic elements of public packet communication. These basic packet communication includes "strict time requirements (time-critical)" communication and "non-time-critical (non-time-critical)" communication. The term "time-critica

GB/T 29910.4-2013: Industrial communication networks -- Fieldbus specifications -- Type 20 HART specification -- Part 4: Application layer protocol specification


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
. Industrial communication networks Fieldbus specifications Type 20 HART specification Part 4... Application layer protocol specification ICS 25.040 N10 National Standards of People's Republic of China Industrial communication networks - Fieldbus specifications Type 20. HART specification Part 4. Application layer protocol specification specification-Part 4. Applicationlayerprotocolspecification (IEC 61158-6-20.2010, Industrialcommunicationnetworks-Fieldbus specification-Part 6-20. Applicationlayerprotocolspecification- Type20elements, IDT) Issued on. 2014-05-01 2013-12-17 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅴ 1 Scope 1 1.1 Overview 1 1.2 specification 1 1.3 Consistency 1 2 Normative references 1 3 Terms and definitions, symbols, abbreviations, conventions 2 3.1 Other standard terms and definitions 2 3.2 IEC /T R61158-1 term 3 Fieldbus application layer specific definitions 3.3 HART 6 3.4 Abbreviations and symbols 7 3.5 Conventions 8 3.6 State Machine conventions 9 4 abstract syntax 10 5 Transfer Syntax 10 5.1 Overview 10 5.2 General APDU structure 10 5.3 Service specific APDU structure 13 5.4 Data Encoding Rules 28 6 FAL protocol state machine structure 34 7 AP vertical relationship between the state machine 35 8 FAL service protocol machine (FSPM) 35 8.1 Overview 35 8.2 FSPM state table 36 8.3 FSPM use function 44 8.4 FSPM/ARPM primitive parameter 45 9 Application Protocol Machine Relationship (ARPM) 45 9.1 AREP mapped to the data link layer 45 9.2 application protocol machine relationship (ARPM) 47 9.3 AREP primitive state machine described 49 9.4 AREP state machine using function 50 10 DLL mapping protocol machine (DMPM) 50 10.1 DMPM state 50 10.2 DMPM state machine 50 10.3 primitives between the data link layer and the exchange of 51 DMPM Function 52 10.4 DMPM use References 53 Figure 1 APDU format 10 Figure 2 from the slave to the master's normal response 11 Figure 3 from the station to the master station command error response 12 4 response from the station to the communication error from the master 12 5 coding without marker 29 in FIG. Figure 6 Integer type data encoding 29 Figure 7 Integer16 type of data encoding 29 8 unsigned type data encoding 29 Figure 9 Unsigned16 type of data encoding 30 10 single-precision floating-point data encoding 30 11 double-precision floating-point data encoding 31 12 Data type data encoding 32 Relations 13 agreements between the machine and the adjacent layers 35 Figure 14 FSPM state transition diagram 36 15 ARPM client state transition diagram 47 16 server ARPM state transition diagram 48 Figure 17 DMPM state transition diagram 50 Table 1 state machine used conventions 9 Table 2 Response Code (Responsecode) value 11 Table 3 device status (Devicestatus) value 11 Table 4 Response Code (Responsecode) value 12 Table 5 Communication error (Commerror) Code 13 Table 6 identifies the request APDU 13 Table 7 identifies the Value field response 14 Table 8 identifies the command-specific response code 15 Value Field Table 9 read primary variable response 15 Table 10 reads the main variable command-specific response code 15 Table 11 reads the loop current and the percentage of responses Value range field 16 Table 12 reads the loop current and the percentage of the range commands specific response code 16 Table 13 read dynamic variables and loop current response of the Value field 16 Table 14 read dynamic variables and loop current command-specific response code 17 Table 15 loop configuration write request Data Field 17 Table 16 Loopcurrentmode Code 17 Table 17 write circuit configuration commands specific response code 17 Table 18 Value of the reading circuit configuration response field 18 Table 19 reads a particular loop configuration command response code 18 Table 20 Value field read variable dynamic response of the family category 18 Table 21 Family Category command read dynamic variables specific response code 19 Data Table 22 field read variable request with the state of the device 19 Value read Table 23 field devices with a state variable response 19 Table 24 Variable status (Variablestatus) value 21 Table 25 read with state variable device-specific command response code 22 Table 26 Value read message response field 22 Table 27 message read command specific response code 23 Table 28 reads labels, Value date field descriptors and response 23 Table 29 reading labels, descriptor and date of the order-specific response code 23 Table 30 Value field read primary variable sensor response 24 Table 31 reads the main variable sensor command-specific response code 24 Reading device information table 32 in response to the Value field 24 Table 33 reads the device information command-specific response code 25 Table 34 reads the final assembly number Response Value field 25 Table 35 reads final assembly number of command-specific response code 25 Table 36 Write message request Data Field 26 Table 37 Write message command-specific response code 26 Table 38 write tag, descriptor and date of the request Data Field 26 Table 39 write tag, descriptor and date of the order-specific response code 27 Table 40 Number requests to write the final assembly of Data Fields 27 Table 41 final assembly number of commands to write specific response code 27 Table 42 Response label read length field 28 Value Table 43 read long command-specific response code label 28 Data Table 44 Length field label request 28 Table 45 Length Labels command-specific response code 28 Table 46 Date type code 31 Table 47 single octet encoded enumerated type 32 Table 48 single octet BitField 33 Table 49 PackedASCII character set 33 Table 50 ISO Latin-1 character AccepTable subset 34 Table 51 FSPM state table - Client Services 36 Table 52 FSPM state table - server processing 44 cases Table 53 Function Command () 44 Table 54 function CommErr () 44 Table 55 function CommandErr () 45 Table 56 function Resp () 45 Table 57 Function Device () 45 Table parameters primitives between 58 and ARPM FSPM exchange used 45 Table 59 Client ARPM state 47 Table 60 Table 48 state clients ARPM Table 61 server status 48 APRM Table 62 Table 49 server status ARPM Table 63 ARPM sent DMPM primitives 49 Table 64 DMPM sent ARPM primitives 49 Parameters 50 Table 65 primitives exchanged between ARPM and DMPM used State Description 50 Table 66 DMPM Table 67 DMPM state table - Client Services 50 Table 68 DMPM state table - server transactions 51 Table 69 primitives between the data link layer and the exchange of 51 DMPM

Foreword

GB/T 29910 "Industrial communication networks - Fieldbus specifications - Type 20. HART specification" is divided into the following six sections. --- Part 1. HART wired network physical layer service definition and protocol specification; Part --- Article 2. HART wired network data link layer service definition and protocol specification; --- Part 3. Application layer service definition; --- Part 4. Application layer protocol specification; Part --- Article 5. WirelessHART wireless communication network and communication profile; --- Part 6. Application layer protocol specification definitions and additional services. This section GB/T Part of 429,910. This section drafted in accordance with GB/T 1.1-2009 given rules. The second objective of this section is to provide existing industrial communication protocols migration path. It is this goal leads to different types of IEC 61158 Diversity of type of service. 1.3 Consistency This section does not specify individual implementations or products, industrial automation system application layer entities are not constrained. Consistency is through Implement the application layer protocol specification to obtain.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 29910.4-2013_English be delivered?

Answer: Upon your order, we will start to translate GB/T 29910.4-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 29910.4-2013_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 29910.4-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.