Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 29302-2012 English PDF

US$579.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 29302-2012: Non-destructive testing instruments -- Characterization and verification of phased array ultrasonic examination systems
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 29302-2012579 Add to Cart 5 days Non-destructive testing instruments -- Characterization and verification of phased array ultrasonic examination systems Valid

Similar standards

GB/T 36015   GB/T 36017   GB/T 36071   GB/T 45391   GB/T 26838   GB/Z 41285.1   

Basic data

Standard ID: GB/T 29302-2012 (GB/T29302-2012)
Description (Translated English): Non-destructive testing instruments -- Characterization and verification of phased array ultrasonic examination systems
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: N78
Classification of International Standard: 19.100
Word Count Estimation: 25,258
Quoted Standard: GB/T 12604.1; ASTM E317; ASTM E494; ASTM E1065; ASTM E1324
Adopted Standard: ASTM E2491-2006, MOD
Regulation (derived from): National Standards Bulletin No. 41 of 2012
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the phased array ultrasonic detector and system performance characteristics evaluation method. This standard can be used to evaluate the use of pulse wave train and A-scan display (RF or video) ultrasonic testing system. This stand

GB/T 29302-2012: Non-destructive testing instruments -- Characterization and verification of phased array ultrasonic examination systems


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Non-destructive testing instruments.Characterization and verification of phased array ultrasonic examination systems ICS 19.100 N78 National Standards of People's Republic of China NDT phased array ultrasonic testing equipment Performance and inspection system Issued on. 2012-12-31 2013-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Overview 2 5. Significance and Use 3 6 Test Method 3 Appendix A (normative) Test phased array beam profile 4 Appendix B (normative) phased array beam deflection range of test 7 Annex C (normative) phased bursts test the effectiveness of 10 yuan Annex D (normative) phased array focused Evaluation 12 Computer-controlled evaluation of Appendix E (normative) phased array parameters and data display 13 Annex F (normative) phased array wedge attenuation and delay compensation 14 Evaluation Annex G (normative) phased array ultrasonic detector linear evaluation 17

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard adopted by the United States to redraft the law to modify the standard ASTME2491-06 "phased array ultrasonic detector and system performance characteristics Evaluation". This standard compared with ASTME2491-06 made the following technical corrections. --- Table G.1 "report linearity correction table" corresponding data "linear amplitude control" in the first line of a paragraph 7 of the original 40, and G4.7 Test Description "100% amplitude adjustment signal to" inconsistent, according to the test described in this standard G4.7 is changed to 100. This standard also made the following editorial changes. --- Standard name was changed to "non-destructive inspection equipment performance and phased array ultrasonic testing system"; --- Deleted ASTME2491-06 foreword, and re-write the foreword; --- Use the "standard" instead of the word "this guide"; --- Amend the introductory phrase in Chapter 2, "Normative references" in; --- Chapter 2, "Normative references" added GB/T 12604.1-2005 "Terminology for nondestructive testing Ultrasonic testing", delete In addition ASTME1316 "Terminology for nondestructive testing"; --- Delete Chapter VII of the keyword feature, focus, phased array, phased array probes, beam profile, ultrasound. --- The normative appendices are numbered from A1 to A7 modify A to G. The standard proposed by China Machinery Industry Federation. This standard by the National Testing Machine Standardization Technical Committee (SAC/TC122) centralized. This standard is mainly drafted by. Shantou Institute of Ultrasonic Instruments Co., Ltd., Nantong Union Digital Technology Development Co., Ltd., Shenzhen, China Testing International Corporation, Wuhan Branch Innovation and Technology Co., Ltd., Liaoning Instrument Research Institute, Shantou Ultrasonic Electronics shares Ltd. Ultrasonic Instrument Branch, Zhongshan City, Guangdong Province Special Equipment Inspection, Changzhou ultrasound Electronics Co., Edson (Xiamen) Electronics Ltd., Taiyuan Heavy Machinery Group Co., Ltd. The main drafters of this standard. Chen Zhi hair, Guozhen Xiang, Zhu Ping, Wang Zicheng, Xu Bo, Chen Wei, Fuyang, PAN Zhen new, Jimmy Lam, Chang Jing Chuan, Ng Kam Lake, Chen Kun. NDT phased array ultrasonic testing equipment Performance and inspection system

1 Scope

1.1 standard specifies the method for the evaluation of phased array ultrasonic detector and system performance characteristics. 1.2 Evaluation of the performance of these aims compare phased array ultrasonic detector and system, or through regular performance evaluation, detecting a specific phase Long-term changes in phased array ultrasonic detector or system performance, evaluate these changes, it is possible to identify potential phased array ultrasonic detector and systems Barrier, and once these changes exceed certain limit, we need to correct maintenance. This standard is based on the ultrasonic detection size of the role played by the relevant It highlighted the need to measure the project. The electrical characteristics similar to other aspects of performance and non-phased array means, in accordance with ASTME1065 "Characteristics of Ultrasonic Evaluation Guide" or ASTME1324 "ultrasonic testing instrument for some electronic characteristic measurement Guide" described measurements. 1.3 This standard can be used to evaluate the use of pulse wave trains and A-Scan display (RF or video) of the ultrasonic testing system. Alarm 1.4 standard can be used to evaluate the integrity of the testing system comprises a probe, phased array ultrasonic detector, coupler, scanning devices, connected And auxiliary equipment, was used to assess the use of the system without changing the case of replacement or duplicate test performance. This standard is not suitable as replacements Phased Array Ultrasonic calibration or standardized procedures or detector system to check for a specific material is carried out. 1.5 standard does not set the test system performance requirements. For such acceptance criteria, to be designated by the consumer. If the text relates to inspection Acceptance criteria, do illustrative purposes only, and always strictly limited customers and end users control file required. 1.6 needs to evaluate specific parameters, conditions and frequency of testing and reporting requirements of the data by the user decide. 1.7 In addition to the phased array ultrasonic testing devices or systems need to be evaluated, the required equipment also includes a test specimen and position encoders. 1.8 standard also includes procedures related to the applicability and interpretation of results Notes. 1.9 Only the customer agrees, can use alternative procedures, such as the example described in this document. Subject 1.10 standard is not intended to solve all the security problems associated with its use. Responsibility of the user of this standard to establish appropriate safety Whole and healthy practices, prior to use to determine the applicability of restrictions.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 12604.1 Terminology for nondestructive testing Ultrasonic testing (GB/T 12604.1-2005, ISO 5577.2000, IDT) ASTME317 implementation methods do not use electronic measuring instruments assessment ultrasonic pulse echo type detection equipment and systems operating characteristics Method of implementation ASTME494 material measuring ultrasonic velocity ASTME1065 ultrasound probe characteristics Assessment Guide ASTME1324 ultrasonic testing equipment for some electronic characteristic measurement guide

3 Terms and Definitions

GB/T 12604.1 defined and the following terms and definitions apply to this document. 3.1 Angle correction gain (ACG) anglecorrectedgain Also known as ACG, used during the S-scan calibration, signal amplitude compensation received from the fixed horizontal hole depth changes. Compensation generally electrically
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 29302-2012_English be delivered?

Answer: Upon your order, we will start to translate GB/T 29302-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 29302-2012_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 29302-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.