GB/T 29023.1-2012 English PDFUS$474.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 29023.1-2012: Measurement and characterization of particles by acoustic methods -- Part 1: Concepts and procedures in ultrasonic attenuation spectroscopy Status: Valid
Basic dataStandard ID: GB/T 29023.1-2012 (GB/T29023.1-2012)Description (Translated English): Measurement and characterization of particles by acoustic methods -- Part 1: Concepts and procedures in ultrasonic attenuation spectroscopy Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: A28 Classification of International Standard: 19.120 Word Count Estimation: 24,284 Adopted Standard: ISO 20998-1-2006, IDT Regulation (derived from): National Standards Bulletin No. 41 of 2012 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the measurement of ultrasonic dispersion in liquids of one or more material particle size distribution concepts and procedures covering the colloidal dispersions, pastes and emulsions, the size of a typical particle size range of 1 GB/T 29023.1-2012: Measurement and characterization of particles by acoustic methods -- Part 1: Concepts and procedures in ultrasonic attenuation spectroscopy---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Measurement and characterization of particles by acoustic methods Part 1. Concepts and procedures in ultrasonic attenuation spectroscopy ICS 19.120 A28 National Standards of People's Republic of China Particle measurement and characterization of ultrasonic method Part 1. ultrasonic attenuation spectroscopy of concepts and processes Part 1. Conceptsandproceduresinultrasonicattenuationspectroscopy (ISO 20998-1.2006, IDT) Issued on. 2012-12-31 2013-10-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsPreface Ⅰ Introduction Ⅱ 1 Scope 1 2 Terms and definitions 1 3 3 Sampling and reference 3.1 Sampling Considerations 3 3.2 reference 3 4. Method 4 4.1 Principle 4 4.2 Instrument 4 4.3 Preparing 5 4.4 Measuring 7 Attenuation data interpretation 4.5 8 5 Results Report 8 5.1 Laboratory Test Report 8 5.2 Online measurement and control applications result 9 Appendix A (informative) Technology 10 Annex B (informative) Application Examples 15 Annex C (informative) decay curve inversion 16 References 18ForewordGB/T 29023 "ultrasonic particle measurement and characterization" is divided into the following three parts. --- Part 1. ultrasonic attenuation spectroscopy concepts and procedures; --- Part 2. Guidelines for linear theory; --- Part 3. Guidelines for linear theory. This is Part 1 GB/T 29023 of. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the translation method identical with ISO 20998-1.2006 "Measurement and characterization of particles by ultrasonic method - Part 1. ultrasonic attenuation spectroscopy Concepts and procedures. " This part of the National particle characterization and sorting and screen Standardization Technical Committee (SAC/TC168) and focal points. This section is drafted. Shanghai University of Technology, Productivity Promotion Center in the machine. The main drafters of this section. Su Mingxu, Cai Shu, Yu Fang, Xue Minghua, Han Xiaolin, Chen Jiaqi, call the sword, Xiao Chen Zhen.IntroductionAs we all know, the ultrasound can be used to measure the spectrum of colloid dispersions and emulsion particle size distribution [6-9]. The basic principle is that when the ultrasonic When passing through the sample, the measurement of ultrasonic attenuation dependent on frequency or speed. This attenuation by particles in the sample of acoustic absorption or scattering Income caused by the dispersion state of the particle size distribution and concentration determines the sound attenuation spectra [10-12]. Once established empirical observations or theoretical calculations Their contact, in principle, can be determined by the ultrasonic particle size distribution data. Ultrasound technology for dynamic online measurement of high concentration slurries and emulsions Very useful. In the past, this test is in quality control laboratories offline, since the equipment is limited by the design principle, the sample must Be detected after dilution. The ultrasound spectroscopy measurement can be directly online at the original concentration, without changing the status of the original sample; and can also Dynamic processes (such as flocculation, dispersion, grinding, etc.) in real-time online measurement. Test data can be directly used for process control in order to improve the process through Process and product performance. This standard consists of three parts. Part 1 ultrasonic attenuation spectroscopy terminology, concepts and processes; Part 2 when the ultrasound spectrum is a linear function of the particle volume concentration, to propose guidelines to determine the particle size spectrum of ultrasound information according to measurement; Part 3 When ultrasound spectrum is a nonlinear function of particle volume concentration, the proposed guidelines to determine the particle size. Particle measurement and characterization of ultrasonic method Part 1. ultrasonic attenuation spectroscopy of concepts and processes1 ScopeThis section GB/T 29023 specifies the ultrasonic measurements of liquid dispersed in one or more of the particle size distribution of the material over the concept and Drive range includes colloids, dispersions, slurries and emulsions, the size of a typical particle size analysis interval 10nm ~ 3mm, but outside this range Around the particles can be measured. Volume concentration of the dispersed phase can be measured range from 0.1% to 50% or even higher, depending on the continuum and points Bulk density contrast quality. This section applies to dynamic change monitoring particle size distribution, including high concentrations of coagulation and flocculation system.2 Terms and definitionsThe following terms and definitions apply to this document. 2.1 Absorption absorption Ultrasonic wave through the media, the removal of acoustic scattering other than the energy loss. 2.2 Attenuation attenuation Muffler extinction Ultrasonic wave through the media, the total acoustic energy losses, including scattering and absorption. Note. The unit of measurement is recommended. decibels (dB). It is defined as the common logarithm of the ratio of 10 times the intensity of the incident and the transmitted ultrasonic wave or ultrasonic wave intensity 20 times Common logarithm of the amplitude ratio of the incident ultrasonic wave and amplitude of the ultrasonic transmission. It can also be selected based on the natural logarithm of the neper (Np) as the unit of measurement, 1Np = 8.686dB. 2.3 Attenuation coefficient attenuationcoefficient Muffler coefficient extinctioncoefficient Ultrasonic acoustic unit length by the media after the energy attenuation, expressed in dB/cm or Np/cm. Note. The attenuation coefficient of frequency or frequency squared sometimes expressed in the form in order to distinguish the main attenuation mechanism. For clarity, only considers the standard unit length Attenuation (dB/cm). 2.4 Attenuation spectrum attenuationspectrum The measured attenuation coefficient as a function of frequency (in abscissa indicates frequency and the ordinate represents the attenuation coefficient of a curve drawn). 2.5 Bandwidth bandwidth Frequency range ultrasonic signals contained Typically, the attenuation 3dB frequency difference between the points on the spectrum analyzer. 2.6 Broadband broadband Wide band ultrasonic signals, characterized in that not less than one-half the bandwidth of the center frequency. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 29023.1-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 29023.1-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 29023.1-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 29023.1-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |