GB/T 28027-2011 English PDFUS$859.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 28027-2011: Railway applications -- Technical criteria for the coordination between power supply and rolling stock to achieve interoperability Status: Valid
Basic dataStandard ID: GB/T 28027-2011 (GB/T28027-2011)Description (Translated English): Railway applications -- Technical criteria for the coordination between power supply and rolling stock to achieve interoperability Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: S04 Classification of International Standard: 45.060 Word Count Estimation: 39,320 Date of Issue: 2011-10-31 Date of Implementation: 2012-04-01 Quoted Standard: GB/T 1402-2010; IEC 61133-2006 Adopted Standard: IEC 62313-2009, MOD Regulation (derived from): Announcement of Newly Approved National Standards No. 15 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies locomotive acceptance for equipment, mainly related to the following aspects: the traction power supply system and the coordination between the units protection principles, in particular the short-circuit fault identification, installation of power lines and trains the coordination between power demand, regenerative braking traction unit and power supply system of coordination between the ability to accept, harmonic characteristics of coordination. This standard " power supply system " within the framework of the provisions of the rolling stock and traction power for the interface between the ground installations. Pantograph and catenary interaction between pantograph and "Control Command" (especially signal) subsystem interaction is not within the scope of this standard. Requirements described in the following line category: Trunk Railroad, urban rail transit. This standard does not apply to infrastructure management sector has received locomotive. But in the new facility conditions, forest management can be based on the development of a protocol to recognize existing rolling stock. GB/T 28027-2011: Railway applications -- Technical criteria for the coordination between power supply and rolling stock to achieve interoperability---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Railway applications. Technical criteria for the coordination between power supply and rolling stock to achieve interoperability ICS 45.060 S04 National Standards of People's Republic of China Rail power supply system and rolling stock running match (IEC 62313.2009, Railwayapplications-Powersupplyandrolingstock- supply (substation) androlingstock, MOD) Issued on. 2011-10-31 2012-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsPreface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Parameters average overall time 4 5 electrical phase 4 6 train power factor 6 7 Train to limit the current 7 8 8 power quality indicators 9 lines and traction power supply system type 9 Harmonics and dynamic effects of 9 10 11 14 protection coordination 12 regenerative braking 15 13 Test 15 14 Test Method 16 Appendix A (informative) parameter average overall time limit 20 Annex B (informative) Selection criteria determine high-speed train pantograph voltage at 21 (Informative) Harmonic characteristics and related overvoltages Appendix C 23 Annex D (informative) harmonic and dynamic effects of compatibility studies data 25 Annex E (informative) different types of electrical phase 29 Annex F (informative) train maximum allowable current value 31 Annex G (informative) OCS - rail short circuit current maximum 32 Closing di Annex H (informative) traction unit circuit breaker/dt 33 References 34ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard uses the redrafted law revision adopted IEC 62313.2009 "Rail power supply system and power supply system for rolling stock (Substation) and rolling stock to run matching technical guidelines. " This standard and IEC 62313.2009 technical differences exist, these differences involve the terms of the margin with a single vertical line (︱) into Row marked. This standard and IEC 62313.2009 technical differences and their reasons are as follows. --- Chapter 1 Scope, according to national circumstances will be divided into a main line railway line and urban rail transport; --- Table 1 for AC drive and DC drive train are classified based on the current actual experience domestic motorcycle manufacturers in the note b The detected total average power factor λ claim adjusted to 0.80; --- Country there is only 50Hz power frequency, so in Tables 2 and 5 to delete the content 16.7Hz, 60Hz deleted Table 5 related content; --- There is no domestic AC15000V, DC3000V, so in Tables 2 and 3 deleted AC15000V, DC3000V related content; --- Table 3 for AC drive and DC drive train classification. This standard also made the following editorial changes. --- Modify the standard name to fit the habits of domestic industry, the standard name will be changed to "rail power supply systems and rolling stock to run Match ", the corresponding English name from" Railwayapplications-Powersupplyandrolingstock-Technical criteriaforthecoordinationbetweenpowersupply (substation) androlingstock "to "Railwayapplications-Technicalcriteriaforthecoordinationbetweenpowersupplyand rolingstocktoachieveinteroperability "; --- Chapter 2 GB/T 25890.1 only informative appendix appears, it changed references; --- Chapter 2 GB/T 2900.36-2003 reference to the term identity, instead references; --- Fixed table referenced in the original 14.4 Error table 4 (table 3 should be), and the three tables numbered Tables 7 to 9; --- In the informative Appendix G, according to the actual situation of the domestic power supply system AC25kV maximum short circuit current to 25kA; --- Deleted the original data Appendix I and references. The standard proposed by the People's Republic of China Ministry of Railways. This standard by the national electric traction equipment and systems Standardization Technical Committee (SAC/TC278) centralized. This standard is mainly drafted by. China Railway Siyuan Survey and Design Group Co., Ltd. This standard is involved in the drafting unit. China Railway Third Survey and Design Institute Group Corporation, China Railway Engineering Consulting Group Co., Ltd., China Railway Electrical Power Design Institute Limited. The main drafters of this standard. yellow foot flat, Wang Meng, Huang Jun, Li Hongmei. Participation drafters of this standard. Qi Guangfeng, Zhongsong Hui, Zhang Huazhi, Zhou Juan, Sun Zhen Yang, SU Peng-cheng, Tian Shengli. Rail power supply system and rolling stock running match1 ScopeThis standard requires the acceptance of the rolling stock equipment, mainly related to the following aspects. --- Coordination between the principle of protection of the power supply system and the traction unit, in particular, is to identify short-circuited; --- Coordination installed power lines between the power demand of the train; --- Traction unit regenerative braking and power supply system to accept coordination between; --- Coordination harmonic characteristics. This standard interface definition and the power supply quality requirements between the tractor unit and ground equipment. The standard in the "Power System" framework provides the interface between the rolling stock and ground power unit for traction. Pantograph And the interaction between the catenary pantograph and "control - command" (especially signal) interaction between subsystems not covered by this standard norm Around inside. Requirements are described in the following line categories. --- Trunk railway; --- Urban Rail Transit. Note. --- Trunk railway including various types of high-speed and conventional railway; --- Urban rail transportation including trams, light rail, subway systems. This standard does not apply to rolling stock infrastructure management sector has received. But in the new facilities, infrastructure management Sector could develop a protocol to recognize the existing rolling stock.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 1402-2010 rail traction power supply system voltage (IEC 60850.2007, MOD) IEC 61133.2006 Railway Vehicles assembled railway facilities and operation of the vehicle before the test (Railwayapplication- Rolingstock-Testingofrolingstockoncompletionofconstructionandbeforeentryintoservice)3 Terms and DefinitionsThe following terms and definitions apply to this document. 3.1 High-speed railway highspeedline New or rebuilt speed target value is greater than or equal to 200km/h lines. 3.2 Conventional railroad conventionalline Conventional cargo and passenger line line, not a 3.1 high-speed rail. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 28027-2011_English be delivered?Answer: Upon your order, we will start to translate GB/T 28027-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 28027-2011_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 28027-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |