GB/T 28026.1-2018 English PDFUS$1319.00 · In stock
Delivery: <= 10 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 28026.1-2018: Railway applications -- Fixed installations -- Electrical safety, earthing and the return circuit -- Part 1: Protective provisions against electric shock Status: Valid GB/T 28026.1: Historical versions
Basic dataStandard ID: GB/T 28026.1-2018 (GB/T28026.1-2018)Description (Translated English): Railway applications -- Fixed installations -- Electrical safety, earthing and the return circuit -- Part 1: Protective provisions against electric shock Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: S80 Classification of International Standard: 45.060 Word Count Estimation: 66,646 Date of Issue: 2018-12-28 Date of Implementation: 2019-07-01 Older Standard (superseded by this standard): GB/T 28026.1-2011 Regulation (derived from): National Standard Announcement No. 17 of 2018 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 28026.1-2018: Railway applications -- Fixed installations -- Electrical safety, earthing and the return circuit -- Part 1: Protective provisions against electric shock---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Railway applications--Fixed installations--Electrical safety, earthing and the return circuit--Part 1. Protective provisions against electric shock ICS 45.060 S80 National Standards of People's Republic of China Replace GB/T 28026.1-2011 Rail transit ground device electrical safety, Grounding and reflow - Part 1. Protection against electric shock thereturncircuit-Part 1.Protectiveprovisionsagainstelectricshock (IEC 62128-1.2013, MOD) Published on.2018-12-28 2019-07-01 implementation State market supervision and administration China National Standardization Administration issued ContentForeword I 1 Scope 1 2 Normative references 1 3 Terms and Definitions 2 4 Provisions for overhead contact area and electrical area 11 5 Direct electric shock protection measures 13 6 protective measures for contact electricity 29 7 Non-traction low-voltage power supply system protection regulations 32 8 Track system used as a protective measure for the traction return circuit or catenary system crossing the danger zone 38 9 Contact voltage limits and hazardous rail potential protection 40 10 Other protective measures 46 Appendix A (Normative Appendix) Warning Sign 49 Appendix B (informative) Typical fence 50 Appendix C (informative appendix) Principles for setting up AC power supply railway return systems 52 Appendix D (Normative) Use of Voltage Limiting Devices (VLD) 54 Appendix E (informative) Effective contact voltage and body current 55 Appendix F (Normative Appendix) Method for measuring effective contact voltage 60 Appendix G (informative) Guideline value for rail potential 61 Reference 63ForewordGB/T 28026 "Electrical safety, grounding and reflow of rail transit ground devices" is divided into three parts. --- Part 1. Electric shock protection measures; ---Part 2. Protective measures for stray currents in DC traction power supply systems; --- Part 3. Interaction of AC and DC traction power systems. This part is the first part of GB/T 28026. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part replaces GB/T 28026.1-2011 "railway ground equipment - Part 1. Electrical safety and grounding related safety Sexual Measures, compared with GB/T 28026.1-2011, the main technical changes are as follows. ---Modified protective measures (see Chapter 5, Chapter 6, Chapters 4 and 5 of the.2011 edition); --- Revised the normative reference document (see Chapter 2, Chapter 2 of the.2011 edition); --- Revised terms and definitions (see Chapter 3, Chapter 3 of the.2011 edition); --- Increased use of voltage limiting devices (VLD) (see Appendix D). This section uses the redrafting method to modify the electrical safety, grounding and return of IEC 62128-1.2013 "railway ground devices". Flow Part 1. Electric Shock Protection Measures. This section has structural differences compared to IEC 62128-1.2013, and the appendix number has been revised, in accordance with the order mentioned in the article. Arrangement, Appendix A is adjusted to Appendix B, Appendix B is adjusted to Appendix A, Appendix C is adjusted to Appendix G, Appendix D is adjusted to Appendix E, Appendix E The adjustments are as Appendix F, Appendix F is adjusted to Appendix D, Appendix I is adjusted to Appendix C, and Appendix G and Appendix H are deleted. There are technical differences in this section compared to IEC 62128-1.2013, and the terms involved in these differences have been passed on the outside margins. The vertical single line (|) of the position is marked. The specific technical differences and their causes are as follows. ---About the normative reference documents, this part has made technical adjustments to adapt to China's technical conditions, adjustments The situation is reflected in Chapter 2, “Regulatory Citations”, and the specific adjustments are as follows. ● Replace IEC 60913.2013 with GB/T 32578-2016 modified to international standards (see 4.1, 4.3, 5.3.1, 10.5.1); ● Replace IEC 60529.1989 with GB/T 4208-2017 equivalent to the international standard IEC 60529.2013 (see 5.3.2.1, Figure 7, 5.3.2.2, Figure 8, Figure 10, 5.3.4); ● Replace IEC 60850 with GB/T 1402 modified to international standards (see 5.6.3.1); ● Replace IEC 62128-2 with GB/T 28026.2 modified to international standards (see 6.2.2.1, 6.2.3.3, 6.3.1.1, 7.2, 7.3.1, 9.3.2.4, 10.1, 10.3.1); ● Replace IEC 62305 (all parts) with GB/T 21714 (all parts) equivalent to the international standard (see 7.1, 10.6); ● Replace IEC 60898-1.2002 with GB/T 10963.1 equivalent to the international standard (see 7.4.4.1, 7.4.4.2); ● Replace IEC 62497-1.2010 with GB/T 32350.1 modified with international standards (see 10.5.1); ● Replace ISO 3864-1.2011 with GB/T 2893.1-2013 modified with international standards (see Appendix A); ● Replace ISO 7010.2011 with GB/T 31523.1-2015 modified with international standards (see Appendix A); ● Replace IEC 61936-1.2010 with dated references with IEC 61936-1, which is not dated (see 10.3.1, 10.1, 9.1.2); ● Removed IEC 60050-101, IEC /T S60479-1.2005, adjusted for reference; ● Added GB/T 2900.1-2008 and GB/T 21413.1 (see 9.1.2, 10.1); ---Modified the requirements for the spacing between the electrified parts of the railway OCS and the branches and bushes, in accordance with the provisions of GB 50061-2011 Line modification (see 5.2.6); ---Modified "DC3kV and below" to "DC1.5kV and below" to make it uniform with GB/T 1402-2010 (see 6.2.2.2); --- Revised the warning sign, consistent with the warning signs used in China (see Appendix A); --- Removed the special national conditions of Appendix G, Appendix HA-deviation, not applicable to China. This section has made the following editorial changes. --- Increased the note of the electrical receiving area, that is, according to the custom of our country, the electrical receiving area can be called the pantograph area or the receiver area (see 3.5.10); --- Revised references. Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This part is proposed by the National Railway Administration. This part is under the jurisdiction of the National Traction Electrical Equipment and Systems Standardization Technical Committee (SAC/TC278). This section is responsible for drafting the unit. China Railway Fourth Survey and Design Institute Group Co., Ltd. Participated in the drafting of this section. China Railway Electrification Survey and Design Institute Co., Ltd., China Railway Fifth Survey and Design Institute Group Co., Ltd. China Railway Design Group Co., Ltd. The main drafters of this section. Wang Zicheng, Wu Dechang, Yan Guangfeng, Chen Min, Wan Yong, Wu Fengjuan, Dong Zhijie. The previous versions of the standards replaced by this section are. ---GB/T 28026.1-2011. Rail transit ground device electrical safety, Grounding and reflow - Part 1. Protection against electric shock1 ScopeThis part of GB/T 28026 gives the ground device of the AC/DC electric traction power supply system and may be affected by the traction power supply system. The electrical safety and protective measures required for the ground facilities. This section applies to the electrical safety requirements of the ground unit maintenance work of the electric traction power supply system. This section applies to all new lines and existing lines to upgrade the electric traction power supply system, including. ---railway; ---guided public transport systems, such as. trams, elevated and underground railways, mountain railways, trolleybus systems and installations Contact system or contact rail magnetic levitation system; --- Material transportation system. This section does not apply to. --- Underground mine traction power supply system; ---Cable cranes, rail transport platforms and similar transport equipment, temporary buildings (eg exhibition structure), because such facilities are currently not available The precedent for powering the net, they are not affected by the traction power supply system; --- Suspension cable car; --- Funicular railway. This section does not stipulate maintenance procedures.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 1402 rail transit traction power supply system voltage (GB/T 1402-2010, IEC 60850.2007, MOD) GB/T 2893.1-2013 Graphical symbols - Safety colours and safety signs - Part 1 Then (ISO 3864-1.2011, MOD) GB/T 2900.1-2008 basic terminology of electrical terminology GB/T 4208-2017 enclosure protection class (IP code) (IEC 60529..2013, IDT) GB/T 10963.1 Electrical accessories - Protection against overcurrent protection for household and similar applications - Part 1 (GB/T 10963.1-2005, IEC 60898-1.2002, IDT) GB/T 16895.21-2011 Low-voltage electrical installations - Part 4-41. Protection against electric shock (IEC 60364-4-41. 2005, IDT) GB/T 17045-2008 General part of electric shock protection devices and equipment (IEC 61140.2001, IDT) GB/T 21413.1 Railway rolling stock -- Electrical equipment - Part 1 . General conditions of use and general rules (GB/T 21413.1-2018, IEC 60077-1.2017, MOD) GB/T 21414-2008 Regulations for the protection of electrical hazards of rolling stock for railway applications (IEC 61991.2000, IDT) GB/T 21714 (all parts) Lightning protection [IEC 62305 (all parts)] GB/T 28026.2 Electrical safety, grounding and recirculation of rail transit ground units - Part 2. Protective measures for scattered current (GB/T 28026.2-2018, IEC 62128-2.2013, MOD) ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 28026.1-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 28026.1-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 6 ~ 10 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 28026.1-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 28026.1-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 28026.1-2018?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 28026.1-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |