GB/T 27903-2011 English PDFUS$209.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 27903-2011: Fire resistance test for lift landing doors -- Methods of measuring integrity, thermal insulation and heat flux Status: Valid
Basic dataStandard ID: GB/T 27903-2011 (GB/T27903-2011)Description (Translated English): Fire resistance test for lift landing doors -- Methods of measuring integrity, thermal insulation and heat flux Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: C82 Classification of International Standard: 13.220.50 Word Count Estimation: 9,931 Date of Issue: 2011-12-30 Date of Implementation: 2012-04-01 Quoted Standard: GB/T 5907; GB/T 14107; GB 7588; GB/T 7633; GB/T 9978.1 Regulation (derived from): Announcement of Newly Approved National Standards No. 23 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the elevator doors fire resistance test methods common terms and definitions, and classification of fire resistance code, test device, specimen condition, specimen preparation, test procedures, test results, test results in order to test the validity of reports. This standard applies to all types of elevator doors. GB/T 27903-2011: Fire resistance test for lift landing doors -- Methods of measuring integrity, thermal insulation and heat flux---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Fire resistance test for lift landing doors. Methods of measuring integrity, thernal insulation and heat flux ICS 13.220.50 C82 National Standards of People's Republic of China The elevator doors fire resistance test Integrity, insulation and heat flux assays measuringintegrity, thernalinsulationandheatflux Issued on. 2011-12-30 2012-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard reference European standards EN81-58.2003 "elevator manufacturing and installation of safety norms inspection and testing - Part 58. Layer Door Fire Test "(in English) about the technical content. The standard proposed by the People's Republic of China Ministry of Public Security. This standard by the National Standardization Technical Committee member fire building fire resistance of the Technical Committee (SAC/TC113/SC8) centralized. This standard was drafted. Ministry of Public Security in Tianjin Fire Research Institute, Longhua Science and Technology Industrial Co., Ltd. The main drafters of this standard. Michael, Zhaohua Li, Li Bo, Li Xi whole, Dong Jing, Diaoxiao Liang, Wang Jinxing, Wang Lan, Nguyen Tao. The elevator doors fire resistance test Integrity, insulation and heat flux assays1 ScopeThis standard specifies the terms and definitions common elevator doors fire resistance test methods, fire resistance and classification code, test device, specimen strip Member, specimen preparation, test procedures, test results, and test the validity of the report of the test results and the like. This standard applies to all types of elevator doors.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 5907 fire first part basic terms GB/T 14107 Fire basic terms of the second part GB 7588 elevator manufacturing and installation of safety norms Resistance test methods GB/T 7633 doors and shutter GB/T 9978.1 building components resistance test methods - Part 1. General requirements3 Terms and DefinitionsGB/T 5907, GB/T 14107, GB/T 9978.1 and define the following terms and definitions apply to this document. 3.1 The elevator doors liftlandingdoor Installed in the elevator shaft each open position for personnel access to the elevator door. 3.2 Insulated elevator door insulatedliftlandingdoor Within a certain period of time to meet the fire integrity of the elevator doors and fire-resistant insulation requirements. 3.3 Non-insulated floor elevator door un-insulatedliftlandingdoor In a certain period of time to meet fire integrity requirements, but also needed to meet the requirements of the elevator door in the heat flux. 3.4 The support structure supportingconstruction Fire resistance test furnace unit, installations for the specimen.4 fire resistance codes and classification4.1 fire resistance code Fire performance indicators elevator door code as follows. --- E. represents integrity; --- I. indicates insulation; --- W. indicates heat flux. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 27903-2011_English be delivered?Answer: Upon your order, we will start to translate GB/T 27903-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 27903-2011_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 27903-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |