GB/T 25749.7-2012 English PDFUS$194.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 25749.7-2012: Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 7: Test bench method for the measurement of the pollutant concentration parameter Status: Valid
Basic dataStandard ID: GB/T 25749.7-2012 (GB/T25749.7-2012)Description (Translated English): Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 7: Test bench method for the measurement of the pollutant concentration parameter Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: J09 Classification of International Standard: 13.110 Word Count Estimation: 10,162 Quoted Standard: ISO 2602; ISO 12100 Adopted Standard: ISO 29042-7-2010, IDT Regulation (derived from): National Standards Bulletin 2012 No. 9 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the given operating conditions, the use of the machine test bench measurements in air emissions from a given concentration of harmful substances as a test method parameters. This method is only applicable to emissions of gases, vap GB/T 25749.7-2012: Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 7: Test bench method for the measurement of the pollutant concentration parameter---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Safety of machinery .Evaluation of the emission of airborne hazardous substances. Part 7. Test bench method for the measurement of the pollutant concentration parameter ICS 13.110 J09 National Standards of People's Republic of China Mechanical safety Assessment of airborne emissions of hazardous substances Part 7. Test bench method for measuring pollutant concentration parameters Part 7. Testbenchmethodforthemeasurementofthepolutant (ISO 29042-7..2010, IDT) 2012-05-11 release.2012-12-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface III Introduction IV 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1 Principle 1 5 test bed 2 5.1 Description of the test bed 2 5.2 Measuring the position of the section 3 6 Procedure 3 6.1 Operation of the machine 3 6.2 Measuring Procedure 3 7 Representation of results 3 8 Test Report 3 Reference 5 ForewordGB/T 25749 "Assessment of Hazardous Substances in Airborne Airborne Discharge" consists of the following nine parts. - Part 1. Selection of test methods; - Part 2. Tracer gas method for measuring emissions of a given pollutant; - Part 3. Test bench method for measuring the emission rate of a given pollutant; - Part 4. Tracer method for measuring the efficiency of exhaust system capture; - Part 5. Test bench method for measuring the quality separation efficiency of air purification systems without conduit exports; - Part 6. Test bench method for measuring the quality separation efficiency of air purification systems with conduit outlet; - Part 7. Test bench method for measuring pollutant concentration parameters; - Part 8. Indoor method for measuring pollutant concentration parameters; Part 9. Purification Index. This part is part 7 of GB/T 25749. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part is equivalent to the use of international standards ISO 29042-7..2010 "Assessment of Hazardous Substances Emissions from Mechanical Safety Airborne Article 7 Part. Test bench method for measuring pollutant concentration parameters ". This part is equivalent to translation ISO 29042-7..2010. For ease of use, this section has made the following editorial changes. - deleted the terms of the ISO /TC199 working area and the relationship between ISO 29042-7 and EN1903-8 content; --- "0.5√AC" in Figure 1 is changed to "0.5 AC", and other similar cases do the same. This part of the National Machinery Safety Standardization Technical Committee (SAC/TC208) proposed and centralized. This part of the drafting unit. Shenzhen, China Testing Technology Co., Ltd., Mechanical Science Research Institute, Nanjing Forestry University, optical machine Engineering Institute. The main drafters of this part. Zhu Ping, Liu Zhiyong, Ju Ronghua, Wu Guangyuan, Zhang Xiaofei, Li Qin, Zheng Meisheng, Ning Yan, Chen Nengyu, Fu Rui.IntroductionThe safety standard structure for the machinery sector is as follows. - Class A standard (basic safety standard), given the basic concepts, design principles and general characteristics applicable to all machinery; - Class B standard (general safety standard), a safety feature involving a mechanical or a wider range of safety devices. ● Class B1, specific safety features (eg safety distance, surface temperature, noise) standard; ● Class B2, safety devices (eg hands operated devices, interlocks, pressure sensitive devices, protective devices) - Class C standards (machine safety standards) that specify a detailed safety requirement for a particular machine or group of machines. According to GB/T 15706, this part belongs to class B standard. The terms of this section may be supplemented or modified by category C standards. For machines designed and constructed in accordance with Class C standards, if the provisions of Class C standards are inconsistent with Class A or Class B criteria, Using Class C standards. Mechanical safety Assessment of airborne emissions of hazardous substances Part 7. Test bench method for measuring pollutant concentration parameters1 ScopeThis part of GB/T 25749 specifies the use of test benches to measure the emissions of machinery in the air under given operating conditions A Test Method for Mass Concentration Parameters. This method is only applicable to the emission of gases, vapors and respirable particles. Wherever possible, the emission rate is determined in the test bed method (see GB/T 25749.3). The pollutant concentration parameters of the measuring machine can be used to. a) assess the performance of the machine; b) assessment of machine improvements; c) comparison between groups of machines of the same intended use (this group is defined by function and processing material); d) classify the same set of machines according to the pollutant concentration parameters; e) Determine the technical level of the machine according to the pollutant concentration parameter.2 normative reference documentsThe following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. ISO 2602 Statistical analysis of the results of the data Estimated confidence interval (Statisticalinterpretationoftestresults- Estimationofthemean-Confidenceinterval) ISO 12100 Mechanical Safety Design General Risk Assessment and Risk Reduction (Safetyofmachinery-General principlesfordesign-Riskassessmentandriskreduction3 terms and definitionsISO 12100 Definitions and the following terms and definitions apply to this document. 3.1 The concentration of pollutants in the tank is polutantconcentrationparameterofthecabin PCC The concentration of a given pollutant measured at a specified location near the machine. Note. In this section, it is preferable to use a measuring section in the exhaust pipe.4 principleThe principle of this measurement method is to operate the machine under controlled conditions in the test bed and to specify the position on the test bench (see 5.2) Amount of contaminant at a specific exhaust flow rate. This concentration represents an emission indicator for the machine. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 25749.7-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 25749.7-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 25749.7-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 25749.7-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |