Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 25749.5-2012 English PDF

US$194.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 25749.5-2012: Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 5: Test bench method for the measurement of the separation efficiency by mass of air cleaning systems with un-ducted outlet
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 25749.5-2012194 Add to Cart 3 days Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 5: Test bench method for the measurement of the separation efficiency by mass of air cleaning systems with un-ducted outlet Valid

Similar standards

GB/T 23821   GB/T 26118.3   GB/T 26118.1   GB/T 25749.8   GB/T 25749.9   GB/T 25749.7   

Basic data

Standard ID: GB/T 25749.5-2012 (GB/T25749.5-2012)
Description (Translated English): Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 5: Test bench method for the measurement of the separation efficiency by mass of air cleaning systems with un-ducted outlet
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: J09
Classification of International Standard: 13.110
Word Count Estimation: 10,131
Quoted Standard: ISO 12100
Adopted Standard: ISO 29042-5-2010, IDT
Regulation (derived from): National Standards Bulletin No. 9 of 2012
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the given operating conditions, the measurement catheter exit without mass separation efficiency air purification system test bench method. This method is suitable for purifying the air in the aerosol (smoke, dust, smoke, haze), st

GB/T 25749.5-2012: Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 5: Test bench method for the measurement of the separation efficiency by mass of air cleaning systems with un-ducted outlet



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Safety of machinery.Evaluation of the emission of airborne hazardous substances.Part 5. Test bench method for the measurement of the separation efficiency by mass cleaning oil systems with unducted outlet ICS 13.110 J09 National Standards of People's Republic of China Mechanical safety Assessment of airborne emissions of hazardous substances Part 5. Measurement of air purification without conduit outlet Test Method of System Quality Separation Efficiency Part 5. Testbenchmethodforthemeasurementoftheseparationefficiencyby (ISO 29042-5..2010, IDT) 2012-05-11 release.2012-12-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface III Introduction IV 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1 Principle 1 5 Description of the test bed 2 6 Air purification system placement and operation 3 7 measurement procedure 3 8 the expression of the results 4 9 Test Report 4 Reference 5

Foreword

GB/T 25749 "Assessment of Hazardous Substances in Airborne Airborne Discharge" consists of the following nine parts. - Part 1. Selection of test methods; - Part 2. Tracer gas method for measuring emissions of a given pollutant; - Part 3. Test bench method for measuring the emission rate of a given pollutant; - Part 4. Tracer method for measuring the efficiency of exhaust system capture; - Part 5. Test bench method for measuring the quality separation efficiency of air purification systems without conduit exports; - Part 6. Test bench method for measuring the quality separation efficiency of air purification systems with conduit outlet; - Part 7. Test bench method for measuring pollutant concentration parameters; - Part 8. Indoor method for measuring pollutant concentration parameters; Part 9. Purification Index. This part is part 5 of GB/T 25749. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part is equivalent to the use of international standards ISO 29042-5..2010 "mechanical safety airborne emissions of harmful substances assessment Part 5. Test bench method for measuring the quality separation efficiency of air purification systems without conduit exports. This part is equivalent to translation ISO 29042-5..2010. For ease of use, this section has made the following editorial changes. - The terms of reference for ISO /TC199 and the relationship between ISO 29042-5 and EN1903-6 have been deleted content; --- 3.1 Note. "Percentage of mass separation efficiency" is changed to "mass separation efficiency" and is added after "100" in formula (1) "%", Other similar cases do the same treatment; --- delete footnote 1 in Chapter 7. This part of the National Machinery Safety Standardization Technical Committee (SAC/TC208) proposed and centralized. This part of the drafting unit. Shenzhen City, China Testing Technology Co., Ltd., Nanjing Forestry University Institute of optical and electrical engineering, mechanical Research Institute. This part of the main drafters. Guo Yong, Ju Ronghua, Zhang Xiaofei, Li Qiang, Li Qin, Ning Yan, Zhao Mao Cheng, Fu Rui, Chen Nengyu, Liu Zhiyong.

Introduction

The safety standard structure for the machinery sector is as follows. - Class A standard (basic safety standard), given the basic concepts, design principles and general characteristics applicable to all machinery; - Class B standard (general safety standard), a safety feature involving a mechanical or a wider range of safety devices. ● Class B1, specific safety features (eg safety distance, surface temperature, noise) standard; ● Class B2, safety devices (eg hands operated devices, interlocks, pressure sensitive devices, protective devices) - Class C standards (machine safety standards) that specify a detailed safety requirement for a particular machine or group of machines. According to GB/T 15706, this part belongs to class B standard. The terms of this section may be supplemented or modified by category C standards. For machines designed and constructed in accordance with Class C standards, if the provisions of Class C standards are inconsistent with Class A or Class B criteria, Using Class C standards. Mechanical safety Assessment of airborne emissions of hazardous substances Part 5. Measurement of air purification without conduit outlet Test Method of System Quality Separation Efficiency

1 Scope

This part of GB/T 25749 specifies the quality separation of air purification systems without a conduit outlet under given operating conditions Efficient test bench method. The method is suitable for the purification of airborne aerosols (smoke, dust, soot, mist), steam or gas systems. The quality separation efficiency of the air purification system used for the intended use is measured and can be used to. a) Evaluation of air purification system performance; b) Improved assessment of air purification systems; c) Comparison between air purification systems; d) classify the air purification system according to the quality separation efficiency; e) Determine the technical level of the same intended use of the air purification system according to the quality separation efficiency.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. ISO 12100 Mechanical Safety Design General Risk Assessment and Risk Reduction (Safetyofmachinery-General principlesfordesign-Riskassessmentandriskreduction

3 terms and definitions

ISO 12100 and the following terms and definitions apply to this document. 3.1 Quality separation efficiency separationefficiencybymass ηs < Air purification system> The pollutant mass (m3) filtered by the air purification system for a given contaminant at a given time Into the air purification system of pollutant mass (m1) ratio. Note. The quality separation efficiency of the air purification system can be expressed as follows. ηs = m3 m1 × 100% (1)

4 principle

The principle of the measurement method is to operate the air purification system on the test bench under specified conditions and to determine the upstream and lower air purification systems The quality of the test substance. The test substance may be an actual contaminant or a substitute, preferably a low toxicity and consistent with the target of the measurement method.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 25749.5-2012_English be delivered?

Answer: Upon your order, we will start to translate GB/T 25749.5-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 25749.5-2012_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 25749.5-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.