GB/T 25749.4-2010 English PDFUS$274.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 25749.4-2010: Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 4: Tracer method for the measurement of the capture efficiency of an exhaust system Status: Valid
Basic dataStandard ID: GB/T 25749.4-2010 (GB/T25749.4-2010)Description (Translated English): Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 4: Tracer method for the measurement of the capture efficiency of an exhaust system Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: J09 Classification of International Standard: 13.110 Word Count Estimation: 14,110 Date of Issue: 2010-12-23 Date of Implementation: 2011-10-01 Quoted Standard: GB/T 15706.1-2007 Adopted Standard: ISO 29042-4-2009, IDT Regulation (derived from): National Standard Approval Announcement 2010 No.10 (Total No.165) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the measurement of the exhaust system installed on the machine capture efficiency. The method is based tracer technique. And be able to test all types of environments (test bench, indoor and outdoor, see GB/T 25749. 1) in operation. The technology is only in the aerodynamic characteristics of the real tracer gas pollutants under comparable circumstances have to apply. GB/T 25749.4-2010: Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 4: Tracer method for the measurement of the capture efficiency of an exhaust system---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Safety of machinery Evaluation of the emission of airborne hazardous substances Part 4. Tracer method for the measurement of the capture efficiency of an exhaust system ICS 13.110 J09 National Standards of People's Republic of China Safety of machinery airborne Part 4 Assessment emissions of harmful substances. Measurement system to capture exhaust efficiency tracer method substances-Part 4. Tracermethodforthemeasurementofthe (ISO 29042-4.2009, IDT) Issued on. 2010-12-23 2011-10-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Principle 1 Simplify the capture efficiency of the expression 2 5 6 Test Method 2 6.1 General Procedure 2 6.2 Measurement of the concentration of C3 4 6.3 Application-specific machine group 5 7 control parameters and factors 5 7.1 General 5 7.2 Control parameters 5 7.3 Effect of capture efficiency factor 6 8 Test Report 6 (95%) to simplify the uncertainty of the random component in Appendix A (Informative Appendix) C3 Calculation 8 Reference 9ForewordGB/T 25749 "assessment of emissions of harmful substances airborne machinery safety" by the following nine components. Selection of test methods. --- Part 1 --- Part 2. Measuring the emission rate of a given pollutant tracer gas method --- Part 3. Measuring the rate of a given pollutant emission test bench method --- Part 4. capture efficiency of an exhaust system measuring tracer method --- Part 5. Measurement of air purification system without conduit outlet mass separation efficiency, test bench method --- Part 6. Measuring the quality of the separation efficiency air purification system with duct outlet, test bench method --- Part 7. measurement of pollutant concentrations, test bench method --- Part 8. Measuring the concentration of pollutants in indoor law --- Part 9. Purification Index This part of GB /Part 4 T 25749 of. This part identical with ISO 29042-4.2009 "Safety of machinery - Assessment airborne emissions of harmful substances - Part 4. Measurement Capture efficiency of an exhaust system tracer method "(in English). This section is equivalent translation ISO 29042-4.2009. For ease of use, this section made the following editorial changes. --- Deleted the ISO foreword, preface rewritten; --- Delete the contents of the introduction on ISO /TC199 scope of work; --- Chapter 1 column item from a) start making; --- The Lead Normative documents according to GB/T 1.1-2009 modified and ISO 29042-4.2009 references country Corresponding to international standards to national standards. This part of the National Safety Standardization Technical Committee (SAC/TC208) and focal points. This section is drafted. Mechanical Science Research Institute, Shanghai China test product Standard Detection Technology Co., Limited LiuGong Division, Nanjing Forestry University Institute of Engineering electromechanical meter. The main drafters of this section. Zhang Xiaofei, Li Qin, Yan Ning, Zhu Ping, Lin JR, ranking splendor, Rui Fu, Fu Dawei, Guo, Wangxi Wei, Song Xiaoning, Huang Zhongliang, Liu Zhiyong.IntroductionMachinery safety standard is structured as follows. --- A class standard (basic safety standards) give basic concepts apply to all mechanical, design principles and general characteristics. --- B class standard (generic safety standards), it relates to a mechanical safety feature or use a wide range of safety devices in class. ● B1 class, specific security features (e.g., safety distance, surface temperature, noise) standard; ● B2 class, the safety device (such as a hand control devices, interlocking devices, pressure sensitive devices, guards). --- C class standards (machine safety standards), for a particular machine or group of machines shall specify detailed safety standard requirements. According to GB/T 15706.1, this section is a Class B standards. Class C standard may supplement or modify the terms of this section. For Class C in accordance with the standard design and construction of the machine, if the C class standards in terms of Class A or Class B standards are inconsistent, priority Using C standard. Safety of machinery airborne Part 4 Assessment emissions of harmful substances. Measurement system to capture exhaust efficiency tracer method1 ScopeThis section GB/T 25749 specifies the measurement of the exhaust system installed on the machine capture efficiency. The method is based on tracer technology Surgery, and can in all types of test environment (test stand, indoor and outdoor, see GB/T 25749.1) in operation. This technique works only if the aerodynamic properties of the tracer gas and real pollutants having comparable circumstances apply (see 7.1.1). Measuring the exhaust system can be used to capture efficiency. a) evaluate machine performance exhaust system; b) improved exhaust system assessment; c) design is similar machine exhaust system; d) in accordance with the capture efficiency of the exhaust system of classification; e) determining the exhaust system to achieve a given air flow to capture the required level of efficiency; f) technology to determine the machine according to the capture efficiency of the exhaust system.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 15706.1-2007 Safety of machinery - Basic concepts, general principles for design - Part 1. Basic terminology, methodology (ISO 12100-1.2003, IDT)3 Terms and DefinitionsGB/T 15706.1-2007 and as defined in the following terms and definitions apply to this document. 3.1 Capture efficiency captureefficiency ηC < Exhaust System> Exhaust System collected directly given this contaminant mass flow of pollutants emitted by machines and uncontrolled mass flow The ratio between the amount. 3.2 Tracer technique tracertechnique Use the aerodynamic characteristics of hazardous substances considered similar and gaseous substance technology concentration can be measured reliably. Principle 4 Principle of measurement method comprising. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 25749.4-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 25749.4-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 25749.4-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 25749.4-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |