GB/T 25276-2010 English PDFUS$139.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 25276-2010: Triacetyl cellulose (TAC) films for liquid crystal display (LCD) -- Determination of thickness Status: Valid
Basic dataStandard ID: GB/T 25276-2010 (GB/T25276-2010)Description (Translated English): Triacetyl cellulose (TAC) films for liquid crystal display (LCD) -- Determination of thickness Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G15 Classification of International Standard: 71.080.99 Word Count Estimation: 6,623 Date of Issue: 2010-09-26 Date of Implementation: 2011-08-01 Quoted Standard: GB/T 2918 Adopted Standard: ISO 4593-1993, NEQ Regulation (derived from): National Standard Approval Announcement 2010 No.6 (Total No.161) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the method for measuring film thickness using cellulose triacetate (TAC) LCD sector (LCD). This standard applies to mechanical measurement and ray method for measuring the thickness of the liquid crystal display g9 shy with TAC. Also apply to an ophthalmic lens with a TAC film thickness measurement. Does not apply to the determination of TAC film thickness lace pressure. GB/T 25276-2010: Triacetyl cellulose (TAC) films for liquid crystal display (LCD) -- Determination of thickness---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Triacetyl cellulose (TAC) films for liquid crystal display (LCD). Determination of thickness ICS 71.080.99 G15 National Standards of People's Republic of China Liquid crystal display (LCD) with triacetate Cellulose ester (TAC) film thickness measurement method Triacetylcelulose (TAC) filmsforliquidcrystaldisplay (LCD) - (ISO 4593.1993, NEQ) Issued on. 2010-09-26 2011-08-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard and ISO 4593.1993 "Plastics film and sheet thickness mechanical scanning Determination" non-equivalent. The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Standardization Technical Committee of the optical thin film materials function (SAC/TC431) centralized. This standard was drafted. China Lucky Film Group Corporation. The main drafters of this standard. Sun Zhiying, Liu province, Xu Lili, INTO. Liquid crystal display (LCD) with triacetate Cellulose ester (TAC) film thickness measurement method1 ScopeThis standard specifies the liquid crystal display (LCD) film thickness measurement method using cellulose triacetate (TAC). This standard applies to mechanical measurement and ray method for a liquid crystal display with a TAC film thickness measurement. Also suitable for use glasses Determination of the film thickness of the TAC. Not for measuring pressure lace TAC film thickness.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2918 plastic sample conditioning and testing of the standard environment3 Terms and DefinitionsThe following terms and definitions apply to this document. 3.1 Optically functional film opticalfunctionalfilms With a variety of original film and functional film excellent optical performance is mainly used in flat panel displays.4 Instrument4.1 Mechanical thickness gauge You should meet the following accuracy. --- 100μm inside (including 100μm) accuracy of 1μm; --- 100μm to 250μm (including 250μm) accuracy of 2μm; --- 250μm above accuracy 3μm. Note 1. When the measuring instrument incapable of higher accuracy requirements, should not use this method, but should be used in a more appropriate measurement instrument or measurement method. ISO 4591 "Plastics film and sheeting measuring the average sample thickness, web thickness and average yield of measuring the weight measurement (gravimetric thickness Degree) "set forth in the weighing method applied thickness was measured. Measuring instrument should have a planar surface and a lower surface measuring surface flat or convex surface on the measurement, all measuring surface should be thrown Light. The vertical measuring surface is a plane/plane, each measuring surface diameter should be between 2.5mm to 10mm, less than two non-parallel plane 5μm. By measuring the surface should be adjusted to meet the above requirements. Measurement should face between the load applied to the specimen in 0.5N to 1.0N. When measuring the upper and lower surfaces of the convex/plane, the radius of curvature of the measuring surface should be between 15mm to 50mm in diameter measured surface should not Less than 5mm, the face should be measured between the load applied to the specimen in 0.1N to 0.5N. Note 2. The pass-through output measurements can use mechanical method (micrometer), an optical method (using a mirror meter) or electrical method (inductive method) and other methods. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 25276-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 25276-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 25276-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 25276-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |