Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 25102.100-2010 English PDF

US$419.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 25102.100-2010: Electroacoustics -- Hearing aids -- Part 0: Measurement of electroacoustic characteristics
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 25102.100-2010419 Add to Cart 3 days Electroacoustics -- Hearing aids -- Part 0: Measurement of electroacoustic characteristics Valid

Similar standards

GB/T 25102.7   GB/T 14471   GB/T 25102.13   GB/T 25102.12   GB/T 25102.8   GB/T 25102.6   

Basic data

Standard ID: GB/T 25102.100-2010 (GB/T25102.100-2010)
Description (Translated English): Electroacoustics -- Hearing aids -- Part 0: Measurement of electroacoustic characteristics
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: M72
Classification of International Standard: 17.140.50
Word Count Estimation: 18,130
Date of Issue: 2010-09-02
Date of Implementation: 2011-04-01
Older Standard (superseded by this standard): GB/T 6657-1986
Quoted Standard: GB/T 3241-1998; GB/T 3769-1983; GB/T 25102.1-2010; GB/T 25102.2-2010; IEC 60711-1981
Adopted Standard: IEC 60118-0-1983, MOD
Regulation (derived from): Announcement of Newly Approved National Standards No. 4 of 2010 (total 159)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the use of free-field measurement techniques and with the ear simulator air conduction hearing aids physical performance characteristics of the method applied in air conduction hearing aids electro-acoustic characteristics are measured,

GB/T 25102.100-2010: Electroacoustics -- Hearing aids -- Part 0: Measurement of electroacoustic characteristics


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
. Electroacoustics Hearing aids Part 0. Measurement of electroacoustical characteristics ICS 17.140.50 M72 National Standards of People's Republic of China Replacing GB/T 6657-1986 Electric acoustic hearing aids Part 0. Measurement of electroacoustical characteristics Part0. Measurementofelectroacousticalcharacteristics (IEC 60118-0. 1983, Hearingaids-Part0. Measurementof electroacousticalcharacteristics, MOD) Issued on. 2010-09-02 2011-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 3 4 Test Equipment 4.1 test chamber acoustic claim 3 4.2 sound field test point 3 4.3 ear simulator 4 4.4 ear simulator device 4 for measuring the sound pressure levels 4 4.5 device for automatic sweep recording 4.6 free-field calibration of sound level 4 5 Test conditions 4 5.1 Test Point Selection 4 5.2 Calibration of sound field 4 5.3 hearing aid test fixture 5 Normal operating conditions of the hearing aid 5 5.4 6 Measurement 6 6.1 Maximum saturation sound pressure level 6 6.2 Input sound pressure level is 90dB sound pressure level at the output of the frequency response of 6 6.3 full-speed acoustic gain frequency response of 6 6.4 overall frequency response and the fundamental frequency response 6 6.5 For the basic tone control position the frequency response of the hearing aid impact 7 6.6 Effect of the position controller gain versus frequency response 7 6.7 gain control characteristic 7 6.8 Effect of the battery or supply voltage changes full stop acoustic gain of 7 6.9 Effect of changes in the internal resistance of the battery or power supply block full acoustic gain of 7 6.10 Effect of battery or supply voltage changes OSPL90 8 Battery current 8 6.11 6.12 hearing amplitude nonlinear measurement 8 6.13 Effect of the supply voltage and the internal resistance of the battery or change the amplitude nonlinearity 9 Inherent noise of the hearing aid 9 6.14 6.15 with a hearing aid induction telecoil input features 10 6.16 AGC circuit having a characteristic of the hearing aid 10 7 Frequency response recording card 10 Appendix A (informative) harmonic distortion and intermodulation distortion 12 References 13

Foreword

GB/T 25102 "electro-acoustics hearing" is divided into 14 parts. --- Part 0. Measurement of electroacoustical characteristics; --- Part 1. an induction pick-up coil input hearing aids; --- Part 2. AGC circuit having a hearing aid; --- Part 3. not entirely worn on the listener hearing aids; --- Part 4. Magnetic field strength in the hearing aid induction loop systems; --- Part 5. papillary insert earphone connector; --- Part 6. hearing input characteristics of the circuit; --- Part 7. When the hearing aid product delivery performance measurement quality inspection; --- Part 8. Methods for measuring performance of hearing aids under simulated actual working conditions; --- Part 9. Methods of measurement characteristics of hearing aids with bone vibrator output; --- Part 11. Symbols and marks of hearing aids and related equipment; --- Part 12. Dimensions of electrical connector system; --- Part 13. Electromagnetic compatibility (EMC); --- Part 14. Specification of a digital interface. This section GB/T 25102 Part 0. The partial modification using IEC 60118-0. 1983 "Acoustic Electric hearing aids - Part 0. Measurement of electroacoustical characteristics" (in English) and IEC 60118-0. 1985/IEC 60118-0Amend.1. No. 19941 amendments. This Part replaces GB/T 6657-1986 "Measurement of electroacoustical characteristics of hearing aids." Compared with the 1986 version, with some changes in this section, in addition to the original content has been supplemented and modified, but also made a version of the series Series modifications, the main changes are as follows. --- This section according to GB/T 1.1-2000 version made editorial changes to the English version of IEC 60118-0 in Chapters 2 3 merge into an introduction, the terms and definitions in Chapter 3 of this standard, followed by other chapters recurrence; --- According to IEC 60118-0Amend.1.1994, an increase of terminology and definitions to explain the contents of 3.17, in the text margins Identified at vertical wire (‖); --- Revised Chapter 7 measuring method measuring step presentation method (not listed in clause 1986 edition, this edition in terms of representation); --- According to IEC 60118-0Amend.1.1994, modified the terms of individual numbers misquoted (GB/T 6657-1986 in 5.4.6 references 6.4.5, 4.4.6 edition modified to reference 5.4.4), the margin in the text are identified by a vertical wire (‖); --- Modify the environmental conditions parameters (original 6.4.4 of temperature, relative humidity and atmospheric pressure values); --- Increasing the intermodulation distortion measurement; --- Modify the presentation of the contents of Appendix A (GB/T 6657-1986 expressed are. measuring machine ear plugging ear simulator, edition Is expressed. harmonic distortion and intermodulation distortion); --- The original text of the coupling cavity to the ear simulator. This section is informative Appendix A Appendix. This part is proposed by the Ministry of Industry and Information Technology of the People's Republic of China. This part of the National Standardization Technical Committee electro-acoustics (SAC/TC23). This section is responsible for drafting. Tianjin hearing plant, Institute of Otolaryngology, Chinese PLA General Hospital. The main drafters of this section. Tanghui De, Chen Hongwen, MO Qingrong, Han Ying root at dawn, Hebei fly.

Introduction

This section describes the evaluation of hearing aid electroacoustic performance measurement method. Selected measurement method is based on a range of optional fixed parameters based on its first consideration is the practicality and reproducibility. because Here, when different models and manufacturers of hearing aids should be noted that the test results were compared with the situation, but in each case can be seized The optional test parameters of the test results comparing the degree of impact. According to the method specified in this part, under the experimental conditions are not necessarily measured performance under actual conditions of use of hearing aids performance fully Consistent. This section does not limit the performance and features of the hearing aid diversification, nor hinder raise the level of technology. In this part of the contents of the biggest changes is the use of a according to IEC 60711 "measuring insert earphones with ear clogging Simulator" in Under the ear simulator. Instead of using IEC 60318-5 "Measurement ear hearing aid with IEC reference coupler" acoustic coupling as specified in Cavity. The results of this change to gain and saturation sound pressure level at some frequencies the measured results with the use of acoustic coupling cavity measured in comparison It has improved significantly. Therefore, the results described in this section use the method can not be directly measured with the previously published GB/T 6657- 1986 "hearing aid electroacoustic characteristics measuring method" or IEC 60118-7 "aids - Part 7. hearing aids for quality inspection of product delivery Can be measured "or GB/T 11453-1989" aids - Part 8. Under simulate actual working conditions of hearing aids Performance Measurement "measured Results were compared. Provisions of this Part are 20μPa SPL reference. Where appropriate, may be abbreviated as SPL SPL. Alternative methods should be point by point measurements measured as a reference, and do the interpretation of the results of comparative law and sound pressure method measured reference. Electric acoustic hearing aids Part 0. Measurement of electroacoustical characteristics

1 Scope

This section provides the use of free-field measurement techniques and physical performance characteristics of air conduction hearing with the ear simulator approach. This section applies to the measurement of air conduction hearing aid electroacoustic characteristics.

2 Normative references

The following documents contain provisions which, through reference GB/T 25102 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 3241-1998 octave and fractional octave filters GB/T 3769-1983 plotting frequency characteristics and polar diagrams of scale and size GB/T 25102.1-2010 electroacoustic aids - Part 1. an induction hearing aid telecoil input (IEC 60118-1.1999, IDT) GB/T 25102.2-2010 electroacoustic aids - Part 2. AGC circuit having a hearing aid (IEC 60118-2. 1983, MOD) IEC 60711. 1981 measured using ear headset with a headset connected by plugging the ear simulator

3 Terms and Definitions

The following terms and definitions apply to this section. 3.1 Ear Simulator earsimulator An apparatus for measuring sound pressure in the headphone output of known acoustic load conditions and predetermined frequency range. It mainly consists of a prescribed body Volume of the cavity, acoustic load networks and calibrated microphone components. Select the microphone position, such that the human ear drum sound pressure at the microphone Sound pressure at the close. (See IEC 60711. 1981) 3.2 Substitution substitutionmethod This measurement is the measurement of hearing aids and free-field sound pressure on the microphone alternately sound field in the same spot. 3.3 Comparative Law comparisonmethod This measurement is the measurement of hearing aids and free-field sound pressure on the microphone while the sound field in acoustic equivalent of two points. 3.4 Sound pressure pressuremethod This measurement is calibrated sound pressure control controls the microphone close to the hearing aid sound-inlet sound pressure level at the input, so, basically It eliminates the effects of diffraction from a hearing aid. 3.5 Real-bit analog method simulatedinsitumethod To simulate a normal adult wearer acoustics, hearing aids installation and measuring method in the simulation of human head and torso.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 25102.100-2010_English be delivered?

Answer: Upon your order, we will start to translate GB/T 25102.100-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 25102.100-2010_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 25102.100-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.