GB/T 22689-2008: Recommended test methods for determining the relative resistance of insulating materials to breakdown by surface discharges
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 22689-2008234 Add to Cart 3 days Recommended test methods for determining the relative resistance of insulating materials to breakdown by surface discharges Valid

Similar standards

GB/T 20632.3   GB/T 20632.2   GB/T 20634.3   GB/T 31034   GB/T 31838.8   GB/T 13542.4   

Basic data

Standard ID: GB/T 22689-2008 (GB/T22689-2008)
Description (Translated English): Recommended test methods for determining the relative resistance of insulating materials to breakdown by surface discharges
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K15
Classification of International Standard: 29.035.99
Word Count Estimation: 12,182
Date of Issue: 2008-12-31
Date of Implementation: 2009-11-01
Adopted Standard: IEC 60343-1991, IDT
Regulation (derived from): Announcement of Newly Approved National Standards No. 23 of 2008 (No. 136 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the relative resistance of solid insulating materials to breakdown by surface discharges of test methods. This standard applies to assessment of solid insulating materials when exposed to the surface discharge capacity relative resistance to breakdown.

GB/T 22689-2008: Recommended test methods for determining the relative resistance of insulating materials to breakdown by surface discharges


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Recommended test methods for determining the relative resistance of insulating materials to breakdown by surface discharges ICS 29.035.99 K15 National Standards of People's Republic of China GB/T 22689-2008/IEC 60343.1991 Determination of solid insulating materials are relatively resistant to breakdown by surface discharges energy Recommended Test Method force (IEC 60343.1991, IDT) Posted 2008-12-31 2009-11-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard is identical with IEC 60343.1991 (2nd edition) "Determination solid insulating materials are relatively resistant to breakdown by surface discharges recommended test Test method "(in English). This standard is technically and IEC 60343.1991 (2nd edition) agreement, only made the following editorial changes. --- Remove the IEC 60343.1991 foreword and introduction, preface to increase national standards; "." --- With a decimal point instead of a comma as the decimal point, ""; --- In the second chapter of normative references, the IEC 60212. 1971 is rewritten as GB/T 10580-2003. The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Electrical insulation materials and insulation systems assessment Standardization Technical Committee (SAC/TC301) centralized. This standard was drafted. Guilin Electric Institute of Science, Technology Electrical Machinery Industry Beijing Institute of Economic Research. The main drafters of this standard. Wang Xianfeng, Guo Liping. This standard is the first release. GB/T 22689-2008/IEC 60343.1991 Determination of solid insulating materials are relatively resistant to breakdown by surface discharges energy Recommended Test Method force

1 Scope

This standard specifies the relative resistance of solid insulating material surface of the test method for the ability to discharge breakdown. This standard applies to the ability to assess the relative resistance of solid insulating materials breakdown when exposed to surface discharge.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 7354-2003 partial discharge measurements (IEC 60270.2000, IDT) GB/T 10580-2003 standard conditions of solid insulating material before the test and during the test used (IEC 60212. 1971, IDT) GB/T 16927 (all parts) high-voltage test techniques (eqv IEC 60060-1, IEC 60060-2) Principle 3 When the solid insulating material is exposed to industrial frequency electric field is generated in the surface discharge, we need to have some simple method to evaluate Given its relative resistance to breakdown and surface discharge capacity. Experience has shown that, during the test, if around the electrode and the surface of the sample is passed through air drying cycle, use several different types of electrodes Generating surface discharge, and complete breakdown of the material as a criterion durability test, similar to the material relating to such stress can be obtained while repeating The classification.

4 test device

4.1 test electrode The test shall use a stainless steel cylindrical electrode and a flat electrode. Stainless steel electrode should meet the following requirements. 4.1.1 cylindrical electrode 6mm ± 0.3mm diameter cylindrical body, down to the edge of a circular arc of radius 1mm. The quality of the electrode is not more than 30g, and It should be placed perpendicular to the sample surface. For soft material, in order to prevent mechanical damage that may occur between the electrode and the sample allowed to have no more than a Over 100μm gap. For thin samples (thickness of less than 100μm), more convenient approach is to be placed between the two electrodes fixed pitch of 100μm. When it is necessary to use small samples to reduce heat capacitance, allowing the use of less than 6mm diameter cylindrical electrode, the electrode edges down into 1mm radius arc. Figure 1 is an example of two electrode means may be employed. When the inter-electrode gap and the sample does not need to be used as shown in Figure 1b) in Electrode means to prevent the occurrence of slight inclination, any other suitable means. 4.1.2 plate electrodes Area flat electrodes should be larger than the area of \u200b\u200bthe cylinder at the test voltage discharge electrode covered. 4.1.3 electrode means Electrode means should have axial symmetry. Location where the air intake should meet the various electrodes have a uniform air distribution as possible in order to maintain Permit reproducible results. On top of one sample can be used to test one or more electrodes. If a plurality of electrodes, electrode spacing should GB/T 22689-2008/IEC 60343.1991
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 22689-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 22689-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 22689-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 22689-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.