GB/T 22194-2008 English PDFUS$199.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 22194-2008: Electrical installations in ships -- Equipment -- Transformers for power and lighting Status: Obsolete
Basic dataStandard ID: GB/T 22194-2008 (GB/T22194-2008)Description (Translated English): Electrical installations in ships -- Equipment -- Transformers for power and lighting Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: U60 Classification of International Standard: 47.020.60 Word Count Estimation: 5,574 Date of Issue: 2008-07-16 Date of Implementation: 2009-04-01 Quoted Standard: IEC 60076; IEC 60076-1-1993; IEC 60076-2-1993; IEC 60076-3-1980; IEC 60076-3-1-1987; IEC 60076-5-1976; IEC 60092-101-1994; IEC 60092 - 401-1987; IEC 60146-1-3-1991; IEC 60726-1982; IEC 60947-4-1-1990 Adopted Standard: IEC 60092-303-1997, IDT Regulation (derived from): National Standard Approval Announcement 2008 No.12 (Total No.125) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard applies to all marine power and lighting transformers, static inverter, also suitable for marine starter transformer, stationary transformer, saturable reactors and magnetic amplifiers, rated capacity of less than 1kVA single-phase transformer and the rated capacity of less than 5kVA three-phase transformer also included in the scope of application. But except for special requirements. GB/T 22194-2008: Electrical installations in ships -- Equipment -- Transformers for power and lighting---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Electrical installations in ships. Equipment. Transformers for power and lighting ICS 47.020.60 U60 National Standards of People's Republic of China GB/T 22194-2008/IEC 60092-303.1997 Marine Electrical Equipment Equipment Power and lighting transformers (IEC 60092-303.1997, Electricalinstalationsinships- Part 303. Equipment-Transformersforpowerandlighting, IDT) Posted 2008-07-16 2009-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard is identical with IEC 60092-303.1997 "Electrical installations in ships - Part 303. Equipment - Transformers for power and lighting." (In English). This standard is equivalent translation IEC 60092-303.1997. For ease of use, this standard made the following editorial changes. --- "This International Standard" be replaced by "this standard"; "." --- With a decimal point instead of a comma as the decimal point, ""; --- Delete international standards preface, introduction; --- Of expression in accordance with the provisions of GB/T 1.1-2000 made changes. The standard proposed by China State Shipbuilding Corporation. This standard by the National Standardization Technical Committee boat ocean. This standard was drafted. Technical and Economic Research Institute of China Shipbuilding Industry. The main drafters of this standard. Li Dayi, Yan Ping. GB/T 22194-2008/IEC 60092-303.1997 Marine Electrical Equipment Equipment Power and lighting transformers1 ScopeThis standard applies to all shipboard power and lighting transformers, static converters, also suitable for marine starting transformers, static transformers, full And reactors and magnetic amplifiers, the rated capacity of less than 1kVA single-phase transformer rated capacity of less than 5kVA and three-phase transformer also pack Included within the scope of application. But except for special requirements.2 General requirementsAll devices in the range mentioned should not only comply with the relevant provisions of the following publications, but also in accordance with this standard and IEC No. 60092 Version was various other articles about additional requirements are listed. IEC 60076 Power Transformers IEC 60076-1.1993 Power transformers Part 1. General IEC 60076-2.1993 Power transformers Part 2. Temperature Rise IEC 60076-3. 1980 Power transformers Part 3. Insulation levels and dielectric strength test, Amendment No. 1 (1981) IEC 60076-3-1. 1987 Power transformers Part 3. Insulation levels and dielectric strength test, Section 1. External air gap IEC 60076-5. 1976 Source transformers Part 5. Ability to withstand short-circuit current, Amendment No. 2 (1994) IEC 60092-101.1994 Electrical installations in ships Part 101. Definitions and general requirements IEC 60092-401. 1987 Electrical installations in ships Part 401. Installation and test of completed IEC 60146-1-3.1991 Semiconductor convertors - General requirements and line commutated converters Part 1-3. transformers and reactors IEC 60726. 1982 dry-type power transformers IEC 60947-4-1.1990 Low-voltage switchgear and control equipment Part 4. contactors and motor starters Section 1. Electromechanical Current contactors and motor starters3 winding arrangementTransformer winding should be designed for dual (two separate windings). Starting Transformer type autotransformer may be used. Terminal 4 Suitable clearly marked terminals should be located in accessible places to facilitate external wiring. These terminals should be effectively secured, and appropriate Spaced or protection, to avoid being accidentally grounded, open circuit or touched.5 cooling arrangement5.1 transformer is preferably a dry air-cooled. Preferably 5.2 liquid-immersed transformers should be sealed. If the oil pillow type, should be designed to conform to IEC 60092-101.1994 regulations, ship Case appears inclined to run without the risk of spillage of liquid. If ventilation measures, it should be properly equipped with desiccant. 5.3 For liquid-immersed transformers should consider configuring a liquid over-temperature alarm and pneumatic protection device. NOTE. Installation Notes See IEC 60092-401. 1987 Chapter 15.6 Voltage RegulationFor resistive load, the secondary voltage between the load and the fixed voltage drop of less than the rated capacity of the transformer should 5kVA per phase GB/T 22194-2008/IEC 60092-303.1997 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 22194-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 22194-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 22194-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 22194-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |