GB/T 20485.12-2008 English PDFUS$374.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 20485.12-2008: Methods for the calibration of vibration and shock transducers -- Part 12: Primary vibration calibration by the reciprocity method Status: Valid
Basic dataStandard ID: GB/T 20485.12-2008 (GB/T20485.12-2008)Description (Translated English): Methods for the calibration of vibration and shock transducers -- Part 12: Primary vibration calibration by the reciprocity method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: J04 Classification of International Standard: 17.160 Word Count Estimation: 19,112 Date of Issue: 2008-03-03 Date of Implementation: 2008-08-01 Older Standard (superseded by this standard): GB/T 13823.18-1997 Quoted Standard: GB/T 20485.1-2008; ISO 266 Adopted Standard: ISO 16063-12-2002, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 3 of 2008 (No. 116 overall) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the use of reciprocity method and the SI international system of units for the absolute calibration of accelerometers used in equipment and operating procedures. This section applies to the frequency range 40Hz ~ 5kHz, acceleration amplitude (depending on frequency) range 10m/s2 ~ 100m/s2 linear accelerometer calibration, this section based on electrodynamic shakers sensor coil as reciprocal situation. And supporting the use of the sensor being calibrated signal Conditioning instrument or amplifier has good characteristics, you can use the method described in this section sensor sensitivity calibration. In order to achieve this part of the provisions of Chapter 3 of measurement uncertainty, should adopt appropriate sensor and information transfer instrument or amplifier matching calibration. GB/T 20485.12-2008: Methods for the calibration of vibration and shock transducers -- Part 12: Primary vibration calibration by the reciprocity method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for the calibration of vibration and shock transducers Part 12. Primary vibration calibration by the reciprocity method ICS 17.160 J04 National Standards of People's Republic of China GB/T 20485.12-2008/ISO 16063-12.2002 Replacing GB/T 13823.18-1997 Vibration and shock sensor calibration method Part 12. vibration calibration by reciprocity method (ISO 16063-12.2002, IDT) Posted 2008-03-03 2008-08-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsPreface Ⅰ 1 Scope 1 2 Normative references 1 3 Measurement Uncertainty 1 4 Symbol 1 Equipment Requirements 2 5 5.1 General 2 5.2 frequency generator and a display or counter 2 5.3 power amplifiers and shaking table 2 Isolation 5.4 shaker block 2 5.5 complex voltage ratio meter 2 5.6 Resistance 2 5.7 Test mass group 3 5.8 distortion measurement instruments 3 5.9 3 oscilloscope Air handling units 3 5.10 Environmental conditions 3 6 7 preferred acceleration amplitude and frequency values \u200b\u200b3 8 Procedure 3 8.1 General 3 8.2 Experiment 4 Sensitivity calculations 4 9 Appendix A (normative) Calculation of Uncertainty 8 Annex B (informative) reciprocity law theory in electromechanical sensor calibration 11 References 15 GB/T 20485.12-2008/ISO 16063-12.2002ForewordGB/T 20485 "vibration and shock sensor calibration method" is expected from the basic concept of the structure, the absolute calibration method, comparative method calibration and the environment Analog calibration and other categories as well as the following components. --- Part 1. Basic Concepts; --- Part 11. vibration calibration by laser interferometry; --- Part 12. Primary vibration calibration by reciprocity; Shock calibration by laser interferometry;. --- Part 13 --- Part 15. Laser interferometry angular vibration calibration; --- Part 21. Vibration calibration by comparison; --- Part 22. Shock calibration by comparison. This part of GB /Part of 12 T 20485. This part identical with ISO 16063-12.2002 "vibration and shock sensor calibration methods - Part 12. Vibration absolute reciprocity law school Accurate "(in English). This section is equivalent translation ISO 16063-12.2002. For ease of use, this section made the following editorial changes. --- The term "international standards in this section" to "this Part"; --- Delete foreword international standards; "." --- With a decimal point instead of a comma as the decimal point, ""; --- Of ISO 16063-12.2002 and other international standards referenced, there is adopted as the equivalent of a standard, instead of using our standard Corresponding to international standards, is not tantamount to the adoption of a standard for the direct reference to international standards. This Part replaces GB/T 13823.18-1997 "vibration and shock sensor calibration method of calibration by reciprocity method." Compared with GB/T 13823.18-1997, the main modifications are as follows. --- Standard name "calibration by reciprocity method" to "vibration calibration by reciprocity method"; --- Original frequency range specified in the standard 40Hz ~ 1250Hz to 40Hz ~ 5000Hz, and equipment required to do the phase It should be adjusted; --- Calibration by the environmental conditions at room temperature 20 ℃ ± 5 ℃ to 23 ℃ ± 3 ℃; --- Choose calibration frequency is changed in accordance with the 1/3 octave; --- Increasing the sensitivity of the accelerometer complex convergence angle (phase shift) Calculation of content; --- Appendix A uncertainty calculated using the new method; Chapter 3 --- increased measurement uncertainty and Chapter 4 symbols; --- Added A. Appendix A 1.2 and A. 2.2 Uncertainty complex sensitivity convergence angle (phase shift) calibration calculations; --- Added Appendix B reciprocity law theory in the electromechanical sensor calibration. Appendix A of this section is normative appendix, Appendix B is an informative annex. This part of the National mechanical vibration, shock and condition monitoring Standardization Technical Committee and centralized. This section drafted by. China Institute of Metrology, Anhui University. The main drafters of this section. Yu Mei, Yang Lifeng, Geli Feng. This part of the standard replaces the previous editions are. --- GB/T 13823.18-1997. GB/T 20485.12-2008/ISO 16063-12.2002 Vibration and shock sensor calibration method Part 12. vibration calibration by reciprocity method1 ScopeThis section provides the use of reciprocity method and SI units for absolute calibration of accelerometers used equipment and operating procedures. This section applies to the frequency range of 40Hz ~ 5kHz, linear acceleration amplitude (depending on frequency) range 10m/s2 ~ 100m/s2 of Accelerometer calibration, this section based on electrodynamic vibration coil is used as the reciprocal of the sensor. Signal Conditioning with the instrument or amplifier is supporting the use of sensors school with good characteristics, you can use the method described in this section were Sensor Calibration. In order to achieve the measurement uncertainty of the provisions of this section of Chapter 3, it should be used with the sensor signal analyzer or put Conditioning Amplifier matching calibration (in this section, the combination of sensor and signal Conditioning instrument or amplifier is referred to as "accelerometer").2 Normative referencesThe following documents contain provisions which, through reference GB/T 20485 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section. However, under this part are encouraged to reach Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 20485.1-2008 vibration and shock sensor calibration methods - Part 1. Basic Concepts (ISO 16063-1.1998, IDT) ISO 266 Acoustics preferred frequency3 Measurement UncertaintyIn 160Hz reference frequency and reference amplitude 100m/s2,50m/s2,20m/s2,10m/s2, the complex sensor sensitivity mode (web Uncertainty value) measuring not more than 0.5%, the argument (phase shift) Measurement uncertainty is not greater than 1 °, the frequency and amplitude of the entire calibration range Inner circle, amplitude measurement uncertainty of the sensitivity of less than 1%, the sensitivity of phase shift measurement uncertainty is not greater than 2 °. It requires all users to be part of this uncertainty estimate according to Annex A, provide documentation of the measurement uncertainty. According to GB/T 20485.1-2008, measurement uncertainty in the measurement of the expanded uncertainty (referred to as "uncertainty").4 SymbolTable 1 shows the general symbols used in this part. For special symbols used in the formula, the formula below was carried out definition. Table 1 Common symbols Symbol Definition Units Shaped test mass ordinal number (like = 0 means no mass) M1 n number of quality test masses like kg U complex voltage V U complex voltage ratio Y complex admittance S GB/T 20485.12-2008/ISO 16063-12.2002 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 20485.12-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 20485.12-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 20485.12-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 20485.12-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |