GB/T 19426-2006 PDF EnglishUS$640.00 · In stock · Download in 9 seconds
GB/T 19426-2006: Method for the determination of 497 pesticides and related chemicals residues in honey fruit juice and wine -- GC-MS method Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Obsolete GB/T 19426: Historical versions
Similar standardsGB/T 19426-2006: Method for the determination of 497 pesticides and related chemicals residues in honey fruit juice and wine -- GC-MS method---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT19426-2006 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 67.050 X 04 Partially Replacing GB/T 19426-2003 Method for Determination of 497 Pesticides and Related Chemicals Residues in Honey, Fruit juice, and Wine – GC-MS Method Issued on: DECEMBER 31, 2006 Implemented on: MARCH 1, 2007 Issued by. General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC. 3. No action is required - Full-copy of this standard will be automatically & immediately delivered to your EMAIL address in 0~60 minutes. Table of ContentsForeword...3 1 Scope... 4 2 Normative References...4 3 Principles... 5 4 Reagents and Materials... 5 5 Apparatus... 6 6 Preparation and Storage of Specimen... 7 7 Test Procedures...7 8 Result Calculation... 9 9 Precision...10 Appendix A...11 Appendix B...26 Appendix C...42 Appendix D...48 Appendix E...53 Appendix F... 68ForewordThis Standard revised GB/T 19426-2003 Method for the Determination of 304 Pesticides Residues in Honey, Fruit Juice and Wine - GC-MS and LC-MS-MS. The major revised contents include. - Pesticides can be determined by GC-MS Method are expanded from 289 to 497 types; - Separate LC-MS-MS Method from this Standard, and revise it into GB/T 20771-2006; - Modify the standard name. This Standard replaced the contents about GC-MS Method in GB/T19426-2003. This Standard’s Appendix A, B, C, D, E and F are informative appendixes. This Standard was proposed by Qinhuangdao Entry-Exit Inspection and Quarantine Bureau of the People’s Republic of China. This Standard shall be under the jurisdiction of General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China. Drafting organizations of this Standard. Qinhuangdao Entry-Exit Inspection and Quarantine Bureau of the People’s Republic of China. Chief drafting staffs of this Standard. Pang Guofang, Fan Chunlin, Liu Yongming, Cao Yanzhong, Zhang Jinjie, Fu Baolian, Jia Guangquan, Li Xuemin, and Wu Yanping. The original standard was first-time issued in 2003; this Standard, together with GB/T 20771-2006, jointly replaced GB/T 19426-2003. Method for Determination of 497 Pesticides and Related Chemicals Residues in Honey, Fruit juice, and Wine – GC-MS Method1 ScopeThis Standard specifies the method for determination of 497 pesticides and related chemicals (see Appendix A) residues in honey, fruit juice and wine by GC-MS Method. This Standard is applicable to the determination of 497 pesticides and related chemicals residues in honey, fruit juice and wine. This Standard’s limit of detection. 0.001 mg/kg ~ 0.300 mg/kg (see Appendix A).2 Normative ReferencesThe provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB/T 6379.1 Accuracy (Trueness and Precision) of Measurement Methods and Results - Part 1. General Principles and Definitions (GB/T 6379.1-2004, ISO 5725-1.1994, IDT) GB/T 6379.2 Accuracy (Trueness and Precision) of Measurement Methods and Results - Part 2. Basic Method for the Determination of Repeatability and Reproducibility of a Standard Measurement Method (GB/T 6379.2-2004, ISO 5725-2.1994, IDT) GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods (GB/T 6682-1992, neq ISO 3696.1987)6 Preparation and Storage of Specimen6.1 Preparation of specimen For the non-crystallization honey sample, mix it evenly. For the crystallization honey sample, under the sealing condition, place it in water not exceeding 60°C to gently heat, vibrate it, after the sample is totally melted, stir it evenly; quickly cool-off to the room temperature. Separate 0.5 kg of sample as the specimen; place it into the sample bottle; seal, and label clearly. For fruit juice and wine sample, pour the total original sample into the clean enameled bucket; fully stir and mix thoroughly, then keep the mixed sample into two portions (500 mL for each portion); seal them, take as specimen, and label clearly. 6.2 Storage of specimen Store the specimen under the room temperature.7 Test Procedures7.1 Extraction Weigh 15 g of specimen (accurate to 0.01 g), place it into 250 mL conical flask with stopper; add 30 mL of water, dissolve 15 min by shaking at the 40°C shaking water bath. Add 10 mL of acetone; then transfer the substances in the flask into 250 mL separatory funnel. Use 40 mL of dichloromethane to wash the conical flask for several times; pour the washings into separatory funnel, carefully emit gas, shake vigorously for eight times; stand for layering; the lower-layer organic phase passes through the cylindrical funnel loaded with anhydrous sodium sulfate; and collect it into 200 mL heart-shaped bottle. Then successively add 5 mL of acetone and 40 mL of dichloromethane into the separatory funnel, shake for 1 min, stand for layering, then collect it. Repeat the extraction for twice, combine the extracted solution, which shall be rotated and evaporated at 40°C water bath till the volume reaches 1 mL, then wait for purification. 7.2 Purification Add 2 cm high of anhydrous sodium sulfate into the Envi-Carb column; connect this column to the top of Sep-Pak-NH2 column; and place the columns in series on the holder of lower heart-shaped bottle. Before adding the sample, use 4 mL of acetonitrile + toluene (3+1) to pre-wash the column; when the liquid surface reaches the top of sodium sulfate, quickly transfer the sample extracted solution on the purifying column; then use 3×2 mL of acetonitrile + toluene (3+1) to wash the sample solution bottle; and transfer the washings into the column. Add 50mL reservoir on the columns in series; use 25 mL of acetonitrile + toluene (3+1) to elute pesticides and ions is consistent with that of the standard sample ions (if relative abundance ratio > 50%, then the allowable deviation is ± 10%; if relative abundance ratio > 20% ~ 50%, then the allowable deviation is ± 15%; if relative abundance ratio > 10% ~ 20%, then the allowable deviation is ± 20%; if relative abundance ratio ≤ 10%, then the allowable deviation is ± 50%), then it can determine that there are pesticides and related chemicals in the sample. If it can’t be confirmed, re-sampling; and confirm through the scanning mode (with enough sensitivity) or increasing other confirmed ions method, or applying other analytical apparatus with higher sensitivity. 7.3.3 Quantitative determination This method applies the single ion quantitative determination of internal standard method. The internal standard substance is heptachlor epoxide. To reduce the influence of matrix, quantitative standard shall adopt matrix mixed standard working solution. The concentration of standard solution is similar to that of the to-be-measured compound. In this method, selected ion monitoring GC-MS diagram of Group A, B, C, D and E standard substances in the honey matrix can refer to Appendix D. 7.4 Parallel test According to the above procedures, carry out the parallel test for the same specimen. 7.5 Blank test It shall be carried out according to the above procedures except for weighing the specimen.8 Result CalculationGC-MS determination result can be automatically calculated by the computer according to the internal standard method, or be calculated according to Formula (1). Where. X - Residual amount of measured substance in the sample, mg/kg; cs - Concentration of measured substance in the matrix standard working solution, µg/mL; A - Chromatographic peak area of measured substance in the sample solution; As - Chromatographic peak area of measured substance in... ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 19426-2006 be delivered?Answer: The full copy PDF of English version of GB/T 19426-2006 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 19426-2006_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 19426-2006_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 19426-2006 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version GB/T 19426-2006?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19426-2006 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of GB/T 19426-2006?A step-by-step guide to download PDF of GB/T 19426-2006_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 19426-2006". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |