GB/T 18443.5-2010: Testing method of performance for vacuum insulation cryogenic equipment - Part 5: Static evaporation rate measurement
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

GB/T 18443.5: Historical versions

Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
GB/T 18443.5-201070 Add to Cart Auto, 9 seconds. Testing method of performance for vacuum insulation cryogenic equipment - Part 5: Static evaporation rate measurement Valid
GB/T 18443.5-2001199 Add to Cart 2 days Testing method of cryo-insulation pressure vessels -- Static evaporation rate measurement Obsolete

Similar standards

GB/T 18443.6   GB/T 18443.4   GB/T 18443.7   GB/T 18443.3   

GB/T 18443.5-2010: Testing method of performance for vacuum insulation cryogenic equipment - Part 5: Static evaporation rate measurement


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT18443.5-2010
NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 23.020 J 74 Replace GB/T 18443.5-2001 Testing method of performance for vacuum insulation cryogenic equipment - Part 5.Static evaporation rate measurement Issued on: SEPTEMBER 26, 2010 Implemented on: FEBRUARY 1, 2011 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of PRC; Standardization Administration of PRC.

Table of Contents

Foreword... 3 1 Scope... 5 2 Normative references... 5 3 Terms and definitions... 6 4 Test principle and method... 6 5 Test devices, equipment, and instruments... 7 6 Test conditions and test preparation... 8 7 Test steps... 8 8 Data processing... 9 9 Test records and test reports... 13 Appendix A (Informative) Static evaporation rate test record (flowmeter method)... 14 Appendix B (Informative) Static evaporation rate test record (weighing method)... 15 Appendix C (Informative) Physical data of nitrogen... 16 Appendix D (Informative) Static evaporation rate test report... 17 Testing method of performance for vacuum insulation cryogenic equipment - Part 5.Static evaporation rate measurement

1 Scope

This part of GB/T 18443 specifies the requirements of the test principle and method, test equipment, equipment and instruments, test conditions and test preparations, test procedures, data processing, test records, and test reports for the measurement of the static evaporation rate of vacuum insulated cryogenic equipment. This part applies to the measurement of the static evaporation rate of vacuum insulated cryogenic equipment, such as vacuum insulated cryogenic pressure vessels except for the storage and transportation of liquid hydrogen medium, and vacuum insulated cryogenic gas cylinders; the measurement of other equipment can be implemented by reference.

2 Normative references

The provisions in the following documents become the provisions of this Part through reference in this Part of GB/T 18443.For the dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this Part, however, parties who reach an agreement based on this Part are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies to this Part. GB/T 18443.1 Testing method of performance for vacuum insulation cryogenic equipment - Part 1.Basic requirements GB/T 18443.2 Testing method of performance for vacuum insulation cryogenic equipment - Part 2.Vacuum degree measurement GB/T 18443.3 Testing method of performance for vacuum insulation cryogenic equipment - Part 3.Leak rate measurement GB/T 18443.4 Testing method of performance for vacuum insulation cryogenic equipment – Part 4.Leak-outgassing rate measurement

3 Terms and definitions

The terms and definitions established in GB/T 18443.1~GB/T 18443.4 and the following apply to this part. 3.1 Percentage loss of product per day The percentage of the mass of cryogenic liquid lost by natural evaporation within 24 h over the mass of cryogenic liquid that is corresponding to the effective volume of the inner pressure vessel, after the cryogenic storage and transportation equipment stands and reaches the thermal equilibrium at the rated fullness rate; the unit is percentage per day (%/d).

4 Test principle and method

4.1 Test principle Use a volume flowmeter or mass flowmeter to measure the natural evaporation of cryogenic liquid per unit time, or use a weighing method to measure the loss of cryogenic liquid per unit time. 4.2 Test method 4.2.1 Use the wet gas flowmeter to measure the gas flow passing through the flowmeter after the liquid in the measured piece evaporates within a unit of time, and calculate the Percentage Loss of Product per Day and the static evaporation rate with the measured gas flow. The schematic diagram of the test device is shown in Figure 1. 4.2.2 Use the gas mass flowmeter to measure the gas mass flow passing through the mass flowmeter after the liquid in the measured piece evaporates within a unit of time, and calculate the Percentage Loss of Product per Day and static evaporation rate with the measured gas mass flow. The schematic diagram of the test device is shown in Figure 2. 4.2.3 When the effective volume of the measured piece is not more than 5 m3, it is allowed to use the weighing method to measure. When the weighing method is used for measurement, after the measured piece is charged to the rated filling quantity, place the measured piece on the weighing instrument, and measure the mass of the cryogenic liquid evaporated in the vacuum insulated cryogenic equipment with the weighing instrument. Use the evaporation measured with the weighing method to calculate the Percentage Loss of Product per Day and static evaporation rate. a) When the range of the flowmeter is less than or equal to 5L/min, the accuracy needs to reach 0.5%; when the range is greater than 5 L/min, the accuracy needs to reach 1.0%; b) The rated flow of the flowmeter shall be compatible with the gas flow evaporated by the measured piece; c) There shall be ambient temperature, ambient pressure, and flowmeter inlet temperature and pressure measurement devices; d) The maximum weighing of the weighing instrument used in the weighing method shall be 1.2~2.0 times the full load mass of the measured piece, and its accuracy shall meet the following requirements. --- When the maximum weighing of the weighing instrument is 5T≤t< 10T, its allowable deviation shall not exceed 1 kg; --- When the maximum weighing of the weighing instrument is 3T≤t< 5T, its allowable deviation shall not exceed 0.5 kg; --- When the maximum weighing of the weighing instrument is 1T≤t< 3T, the allowable deviation shall not exceed 0.2 kg; --- When the maximum weighing of the weighing instrument is t< 1T, its allowable deviation shall not exceed 0.1 kg.

6 Test conditions and test preparation

Test conditions and test preparations shall comply with the provisions of GB/T 18443.1.

7 Test steps

7.1 Flowmeter method 7.1.1 Liquid nitrogen is generally used as the test medium. 7.1.2 During measurement, the fullness rate of cryogenic liquid shall be the rated fullness rate. 7.1.3 After the liquid filling is completed, it shall be standing for at least 48h. During the standing period, the venting valve of the vacuum insulated cryogenic equipment shall be opened. 7.1.4 When the gauge pressure of the inner liner is close to zero, connect the flowmeter to the venting pipeline. After the flowmeter is connected, except the venting valve is opened, the other valves of the measured piece shall be all closed. 7.1.5 After the flow of evaporated gas is stabilized, collect and record the indicated value of the flowmeter, ambient temperature, atmospheric pressure, flowmeter inlet temperature and pressure with a time interval that shall not be more than 1 h; the data recording time shall be 24 h. 7.1.6 Calculate the static evaporation rate of the measured piece and compare it with the static evaporation rate of the previous 24 h. When the variation range of the static evaporation rate is less than 5%, the recorded data is valid; when the variation range of the static evaporation rate is greater than 5%, it is allowed to record the data once again; the recording time shall not be less than 24 h, and the data are final record data. 7.2 Weighing method 7.2.1 Except for special requirements, the test medium shall be liquid nitrogen. 7.2.2 During measurement, the cryogenic liquid fullness rate shall be rated fullness rate. 7.2.3 After the liquid filling is completed, it shall be standing for 48 h before the start of recording data. During the standing period, the venting valve of the vacuum insulated cryogenic equipment shall be opened. 7.2.4 When the gauge pressure of the inner liner is close to zero, except the venting valve is opened, the other valves of the measured piece shall be all closed; record the initial data of the weighing instrument at the same time. 7.2.5 Record the data of the weighing instrument when the time interval is 24 h and 48 h.

8 Data processing

8.1 Percentage loss of product per day α0 8.1.1 When the wet gas flowmeter is used for measurement, the percentage loss of product per day α0 is calculated according to formula (1). Where. α0 --- The percentage loss of product per day, and the unit is percentage per day (%/d); qv --- The daily average value of volume flow of evaporated gas, in cubic meters per Where. α0 --- The percentage loss of product per day, and the unit is percentage per day (%/d); qg --- The mass of gas evaporated within 24 hours, in kilograms per day (kg/d); ρ1 --- The density of the saturated liquid at standard atmospheric pressure (101.325 kPa), in kilograms per cubic meter (kg/m3); V --- The effective volume of the measured piece, in cubic meters (m3). 8.2 Calculation of static evaporation rate 8.2.1 The static evaporation rate of high vacuum multilayer insulation α20 is calculated according to formula (4). Where. α20 --- The static evaporation rate, and the unit is percentage per day (%/d); α0 --- The percentage loss of product per day, and the unit is percentage per day (%/d); h --- The latent heat of vaporization of the saturated liquid at test ambient pressure, in kilojoules per kilogram (kJ/kg); hfg --- The latent heat of vaporization of the saturated liquid at standard atmospheric pressure (101.325 kPa), in kilojoules per kilogram (kJ/kg); Ts --- The temperature of the saturated liquid at standard atmospheric pressure (101.325 kPa), and the unit is Kelvin (K); T1 --- The daily average ambient temperature during the test, and the unit is Kelvin (K); T2 --- The saturation temperature of the cryogenic liquid that is corresponding to the daily average pressure in the measured piece during the test, and the unit is Kelvin (K). 8.2.2 The static evaporation rate α20 of the vacuum insulation of the powder or fiber is calculated according to formula (5). Where. α20 --- The static evaporation rate, and the unit is percentage per day (%/d); α0 --- The percentage loss of product per day, and the unit is percentage per day (%/d); h --- The latent heat of vaporization of the saturated liquid at test ambient pressure, in kilojoules per kilogram (kJ/kg); hfg --- The latent heat of vaporization of the saturated liquid at standard atmospheric pressure (101.325 kPa), in kilojoules per kilogram (kJ/kg); Ts --- The temperature of the saturated liquid at standard atmospheric pressure (101.325 kPa), and the unit is Kelvin (K); T1 --- The daily average ambient temperature during the test, and the unit is Kelvin (K); T2 --- The saturation temperature of the cryogenic liquid that is corresponding to the daily average pressure in the measured piece during the test, and the unit is Kelvin (K). 8.2.3 The static evaporation rate α20 of high vacuum insulation is calculated according to formula (6). Where. α20 --- The static evaporation rate, and the unit is percentage per day (%/d); α0 --- The percentage loss of product per day, and the unit is percentage per day (%/d); h --- The latent heat of vaporization of the saturated liquid at test ambient pressure, in kilojoules per kilogram (kJ/kg); hfg --- The latent heat of vaporization of the saturated liquid at standard atmospheric pressure (101.325 kPa), in kilojoules per kilogram (kJ/kg); Ts --- The temperature of the saturated liquid at standard atmospheric pressure (101.325 kPa), and the unit is Kelvin (K); T1 --- The daily average ambient temperature during the test, and the unit is Kelvin (K); ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of GB/T 18443.5-2010 be delivered?Answer: The full copy PDF of English version of GB/T 18443.5-2010 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 18443.5-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18443.5-2010_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 18443.5-2010 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB/T 18443.5-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18443.5-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB/T 18443.5-2010?

A step-by-step guide to download PDF of GB/T 18443.5-2010_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 18443.5-2010".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9