GB/T 18403.6-2013 English PDFUS$294.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 18403.6-2013: Expression of performance of gas analyzers -- Part 6: Photometric analyzers Status: Valid
Basic dataStandard ID: GB/T 18403.6-2013 (GB/T18403.6-2013)Description (Translated English): Expression of performance of gas analyzers -- Part 6: Photometric analyzers Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: N53 Classification of International Standard: 71.040.10 Word Count Estimation: 15,138 Quoted Standard: IEC 61207-1-1994; IEC 60654-1; IEC 60654-2; IEC 60654-3; IEC 60654-4; ISO 9001; ISO 9002; ISO 9003 Adopted Standard: IEC 61207-6-1994, IDT Regulation (derived from): National Standards Bulletin 2013 No. 10 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard applies to: the use of photometric techniques to measure mixed gas or vapor concentration one or more components of various types parser. GB/T18403. 1-2001 combined with the use of this standard. This standard applies to the use of non- disp GB/T 18403.6-2013: Expression of performance of gas analyzers -- Part 6: Photometric analyzers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Expression of performance of gas analyzers Part 6. Photometric analyzers ICS 71.040.10 N53 National Standards of People's Republic of China Performance of gas analyzers Part 6. Photometric Analyzer (IEC 61207-6.1994, IDT) Issued on. 2013-07-19 2013-12-15 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordGB/T 18403 "performance of gas analyzers" have or plan to release the following sections. --- Part 1. General; --- Part 2. Oxygen in gas (high-temperature electrochemical sensors); --- Part 3. paramagnetic oxygen analyzer; --- Part 6. Photometric analyzers. This section GB/T 18403 Part 6. This section drafted in accordance with the rules of GB/T 1.1-2009 and GB/T 20000.2-2009 given. This section uses the translation method is equivalent to using IEC 61207-6.1994 "performance of gas analyzers - Part 6. Photometric Analyzer." Consistency correspondence between this part of international documents and normative references of our files are as follows. --- GB/T 17214 (all parts) industrial process measurement and control equipment - Operating conditions [IEC 60654 (all parts)] --- GB/T 18403.1-2001 performance of gas analyzers - Part 1. General (eqv IEC 61207-1.1994) --- GB/T 19001-2008 quality management system requirements (ISO 9001.2008, IDT) Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This part is proposed by China Machinery Industry Federation. This part of the measurement and control of Standardization Technical Committee (SAC/TC124) is administered by the National industrial processes. This section drafted by. China Instrument Industry Association, Foshan Analyzer Ltd., Sichuan-Chongqing Analytical Instruments Co., Ltd., Beijing Institute of Metrology detection, Shanghai Institute of Measurement and Testing, FPI (Hangzhou) Co., Ltd., Beijing Analytical Instrument Institute. The main drafters of this section. Maya Juan, one thousand Ye Jun, Zhu Zhongwen, Zhao Haibo, Cai Jianhua, Yu Dahai, Louxing Jun.IntroductionPhotometric analyzer using UV detector for different wavelengths of the electromagnetic spectrum (180nm ~ 20μm), the visible and infrared light response Detecting instrument. Within these wavelength ranges having a plurality of gas absorption/emission spectrum. Using these spectral analyzer designed to be Using a variety of techniques, including absorption and stimulated emission spectra, and the intensity of the radiation/response wavelength conversion. The volume of gas to be measured can Sample cell is controlled by the sample gas can be treated or not, can directly measure its concentration in the sample gas. Performance of gas analyzers Part 6. Photometric Analyzer1 ScopeGB/T 18403 in this section apply to the use of spectrophotometric techniques to measure various types of mixed gas of one or more components or vapor concentrations Type of analyzer. This portion of the GB/T 18403.1-2001 combination. This section applies to the use of the analyzer and the use of the non-dispersive and dispersive wavelength selection absorption spectra, emission spectra or wavelength conversion technique Analyzer. This section applies to all types of measuring gas sample analyzer, whether or not sample gas, sample gas or in a vacuum, atmospheric and pressurized Article Member under can. This section applies to directly measure the gas concentration in the sample gas in all types of analyzer. The purpose of this section is. --- Provisions photometric technology utilizing continuous measurement air supply terms and definitions gas or vapor concentration in the gas analyzer functional properties; --- Unified class analyzer features and verification methods; --- Specifies the test content and test methods for determination of functional characteristics should be carried out; --- Provide basic document for the ISO 9001, ISO 9002 and ISO 9003 quality management standard applications.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. IEC 61207-1.1994 performance of gas analyzers - Part 1. General (Expressionofperformanceofgasan- alyzers-Part 1. General) IEC 60654 (all parts) industrial process measurement and control equipment - Operating conditions (Industrial-processmeasurementand controlequipment-Operatingconditions) ISO 9001 quality management system requirements (Qualitymanagementsystems-Requirements) Quality assurance model ISO 9002 quality system of production, installation and service (Qualitysystems-Modelforqualityas- suranceinproduction, instalationandservicing) ISO 9003 quality system for final inspection and test quality assurance model (Qualitysystems-Modelforqualityas- suranceinfinalinspectionandtest)3 Terms and DefinitionsFigure A.1 and A.2 shows the relationship between the various types of analyzers. 3.1 Infrared analyzer infraredanalyzer A photoelectric instrument. It includes single or dual infrared light infrared light source and one or more of an infrared detector. This detector by measuring Determination of specific components of the optical path to be measured characteristic absorption spectrum. Note 1. This section applies to the manufacturer to adjust the analyzer to select only the components measured spectral region characteristic absorption spectra measured length of the channel should be applied to points ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 18403.6-2013_English be delivered?Answer: Upon your order, we will start to translate GB/T 18403.6-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 18403.6-2013_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 18403.6-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |