Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 18268.1-2025 English PDF

US$444.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 18268.1-2025: Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
Status: Valid

GB/T 18268.1: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 18268.1-2025444 Add to Cart 4 days Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements Valid
GB/T 18268.1-2010115 Add to Cart Auto, < 3 mins Electrical equipment for measurement, control and laboratory use -- EMC requirements -- Part 1: General requirements Valid
GB/T 18268-2000679 Add to Cart 3 days Electrical equipment for measurement, control and laboratory use. EMC requirements Obsolete

Similar standards

GB/T 18271.1   GB/T 18271.2   GB/T 18268.26   GB/T 18268.22   GB/T 18268.31   GB/T 18268.32   

Basic data

Standard ID: GB/T 18268.1-2025 (GB/T18268.1-2025)
Description (Translated English): Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: N10
Classification of International Standard: 17.220.20, 25.040.40, 33.100.20
Word Count Estimation: 22,274
Date of Issue: 2025-06-30
Date of Implementation: 2026-01-01
Older Standard (superseded by this standard): GB/T 18268.1-2010
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 18268.1-2025: Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT18268.1-2025
ICS 17.220.20;25.040.40;33.100.20 CCSN10 National Standard of the People's Republic of China Replaces GB/T 18268.1-2010 Electrical equipment for measurement, control and laboratory use Electromagnetic compatibility requirements Part 1.General requirements EMCrequirements-Part 1.Generalrequirements Released on June 30, 2025 Implementation on January 1, 2026 State Administration for Market Regulation The National Standardization Administration issued

Table of Contents

Preface III Introduction V 1 Scope 1 2 Normative references 2 3 Terms, Definitions and Abbreviations 3 3.1 Terms and Definitions 3 3.2 Abbreviations 5 4 General Principles 6 5 Electromagnetic compatibility test plan 6 5.1 General Principles 6 5.2 Configuration of EUT during test 6 5.3 EUT operating conditions during the test 7 5.4 Functional Characteristics Specification 7 5.5 Test description 7 6 Immunity Requirements 7 6.1 Test conditions 7 6.2 Immunity test requirements 8 6.3 Accidental Aspects 10 6.4 Performance criteria 10 7 Launch Requirements 11 7.1 Measurement conditions 11 7.2 Emission limits 11 8 Test results and test reports 12 9 Instructions for Use12 Appendix A (Normative) Immunity test requirements for portable test and measuring equipment powered by batteries or the circuit under test 13 Appendix B (Informative) Guide to Electromagnetic Compatibility Analysis and Evaluation 14 B.1 Overview 14 B.2 Risk Analysis 14 B.3 Risk Assessment14 Reference 15 Preface This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document is Part 1 of GB/T 18268 "Electromagnetic compatibility requirements for electrical equipment for measurement, control, and laboratory use". The following parts have been published. --- Part 1.General requirements; --- Part 21.Special requirements for test configuration and working conditions of sensitivity test and measurement equipment for applications without electromagnetic compatibility protection and performance criteria; --- Part 22.Particular requirements Test configuration, operating conditions and requirements for portable test, measuring and monitoring equipment for low-voltage distribution systems Performance criteria; --- Part 23.Special requirements for test configurations, operating conditions and performance criteria for transmitters with integrated or remote signal conditioning; --- Part 24.Particular requirements for insulation monitoring devices in accordance with IEC 61557-8 and insulation fault determination devices in accordance with IEC 61557-9 Test configuration, operating conditions and performance criteria of the equipment; --- Part 25.Special requirements for test configuration, operating conditions and performance of field devices with interfaces conforming to IEC 61784-1, CP3/2 Able to judge; --- Part 26.Particular requirements for in vitro diagnostic (IVD) medical devices; --- Part 31.Immunity requirements for safety-related systems and equipment intended to perform safety-related functions (functional safety) General industry application; --- Part 32.Immunity requirements for safety-related systems and equipment intended to perform safety-related functions (functional safety) Specific electromagnetic Industrial applications of the environment. This document replaces GB/T 18268.1-2010 "Electrical equipment for measurement, control and laboratory use - Electromagnetic compatibility requirements - Part 1. Compared with GB/T 18268.1-2010, in addition to structural adjustments and editorial changes, the main technical changes are as follows. --- Changed the immunity test values (see Table 1, Table 2, Table 3, 6.2 of the.2010 edition); --- Changed the performance criteria (see 6.4, 6.4 of the.2010 edition); --- Changed the requirements for emission limits (see 7.2, 7.2 of the.2010 edition); --- Changed the requirements for portable test and measuring equipment (see Appendix A, Appendix A of the.2010 edition). This document is equivalent to IEC 61326-1.2020 "Electromagnetic compatibility requirements for electrical equipment for measurement, control, and laboratory use Part 1 Part 1.General Requirements. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed by the China Machinery Industry Federation. This document is under the jurisdiction of the National Technical Committee for Standardization of Industrial Process Measurement, Control and Automation (SAC/TC124). This document was drafted by. Shanghai Industrial Automation Instrumentation Research Institute Co., Ltd., Shanghai Instrument and Control System Inspection and Testing Co., Ltd. Shanghai Yidian Artificial Intelligence Innovation Institute Co., Ltd., Chongqing Kairui Certification Service Co., Ltd., Guangxi Zhuang Autonomous Region Medical Device Testing Center Center, Chongqing Jinshan Medical Robotics Co., Ltd., Siemens Medical Systems Co., Ltd., Liaoning Provincial Inspection and Certification Center, Shanghai Quality Supervision Inspection Technology Research Institute, Weikai Testing Technology Co., Ltd., National Nuclear Automatic Instrument System Engineering Co., Ltd., Dongguan Jingbang Machinery Technology Co., Ltd. Co., Ltd., Jiangsu Medical Device Inspection Institute, Hubei Medical Device Quality Supervision and Inspection Institute, Shanghai Youli Testing Technology Co., Ltd., Chongqing Chuanyi Automation Co., Ltd., Beijing Zhongrong Zhihe Technology Co., Ltd., Xiamen Yudian Automation Technology Co., Ltd., Shanghai Chuangjing Testing Technology Co., Ltd., Shanghai Institute of Metrology and Testing Technology, Shanghai Institute of Medical Device Inspection, Siyuan Electric Co., Ltd., China Electronics Technology Standardization Institute. The main drafters of this document are. Yu Lei, Xiao Honglian, Wang Ying, Sun Tianfei, Qiang Xiaolong, Huang Yu, Yang Kai, Zhou Pengcheng, Zhao Jiayang, Zhang Pei, Sun Yuxin, Chen Yongqiang, Liu Aiqing, Zhang Aisen, Ding Yi, Lin Tao, Fei Jie, Fu Haitao, Wang Rong, Zou Mingwei, Han Jian, Yao Yi, Su Xiaoli, Zhao Huasheng, Jin Shanyi, Jiang Sui, Liu Long, Qiao Jiayi, and Cui Qiang. The previous versions of this document and the documents it replaces are as follows. ---First issued as GB/T 18268.1-2000 in.2000 and first revised in.2010; ---This is the second revision.

introduction

The instruments and equipment covered in this document may be geographically dispersed and therefore required to operate under a wide range of environmental conditions. The electromagnetic emissions are not expected to be high enough to ensure that other equipment installed in the vicinity is not unduly affected by the equipment under consideration. However, the device is intended for operation in its intended location. In this regard, this document specifies three different types of electromagnetic environments and Immunity level. For more information on electromagnetic environment issues, refer to IEC TR61000-2-5. This does not include situations such as electrical shock, circuit breaker operation or abnormally high electromagnetic radiation in close proximity. Complex electrical and/or electronic systems are not designed or EMC planning is required at all stages of installation, taking into account the electromagnetic environment, any special requirements and the severity of the fault. This document specifies general EMC requirements applicable to all equipment within its scope. For some types of equipment, these requirements will be determined by One or more specific requirements of GB/T 18268.2× supplement or modify these requirements. These are read in conjunction with the requirements of IEC 61326-1. GB/T 18268 "Electromagnetic compatibility requirements for electrical equipment for measurement, control and laboratory use" has been published and is planned to consist of 9 parts composition. --- Part 1.General requirements. The purpose is to specify the electromagnetic requirements of electrical equipment for professional, industrial process, industrial manufacturing and educational use Compatibility immunity and emission requirements, these electrical devices are powered by less than AC 1000V or DC 1500V power supply or battery, Or powered by the line under test, including equipment and computing devices used in industrial and non-industrial locations. --- Part 21.Special requirements for test configuration and working conditions of sensitivity test and measurement equipment for applications without electromagnetic compatibility protection The purpose is to specify in more detail the equipment with test and measurement circuits (internal and (or) external circuits of the equipment) The test configuration, working conditions and performance criteria of these devices are specified by the manufacturer for operational and/or functional reasons. There is no electromagnetic compatibility protection. This document is used in conjunction with GB/T 2624.1. --- Part 22.Particular requirements Test configuration, operating conditions and performance of portable test, measuring and monitoring equipment for low-voltage distribution systems The purpose is to specify in more detail the test, measurement or monitoring equipment of low voltage distribution system protection facilities, which consists of batteries and (or) Test configuration, operating conditions and performance criteria for equipment powered by the circuit under test and portable equipment. This document is compatible with GB/T 2624.1 Suitable for use. --- Part 23.Special requirements for test configurations, operating conditions and performance criteria for transmitters with integrated or remote signal conditioning. The purpose is to define in more detail the conversion function, which is characterized by the conversion of non-electrical quantities into process-related quantities with the help of auxiliary energy. The test configuration and working principle of the transmitter for measuring electrochemical quantity and biomass are provided. Conditions and performance criteria. --- Part 24.Particular requirements for insulation monitoring devices in accordance with IEC 61557-8 and insulation fault determination devices in accordance with IEC 61557-9 The purpose is to provide more detailed provisions for the test configuration, operating conditions and performance criteria of the equipment in accordance with IEC 61557-8. Test configuration, operating conditions and performance criteria for monitoring devices and insulation fault location equipment according to IEC 61557-9. --- Part 25.Special requirements for test configuration, operating conditions and performance of field devices with interfaces conforming to IEC 61784-1, CP3/2 The purpose is to discuss the special requirements of electromagnetic compatibility testing of field devices for interfaces that meet IEC 61784-1, CP3/2. --- Part 26.Particular requirements for in vitro diagnostic (IVD) medical devices. The purpose is to Electromagnetic environment, specifies the basic requirements for its electromagnetic compatibility, immunity and emission. --- Part 31.Immunity requirements for safety-related systems and equipment intended to perform safety-related functions (functional safety) General industry Application. The purpose is to specify the expected performance of SIL1 to SIL3 in IEC 61508 in the electromagnetic environment of indoor and outdoor industrial sites. Immunity requirements for industrial systems and equipment for safety functions. --- Part 32.Immunity requirements for safety-related systems and equipment intended to perform safety-related functions (functional safety) Specific electromagnetic The purpose is to specify the specific electromagnetic environment obtained by applying mitigation measures in indoor and outdoor industrial locations. Under the IEC 61508 SIL1 to SIL3, the systems and equipment used in industrial applications that are intended to perform safety functions are immune to disturbances. Degree requirements. Electrical equipment for measurement, control and laboratory use Electromagnetic compatibility requirements Part 1.General requirements 1 Scope This document specifies the voltage of the power supply or battery below 1000V AC or 1500V DC, or the circuit under test. Electromagnetic compatibility (EMC) immunity and emission requirements for electrical equipment that supplies power. This document applies to electrical equipment for professional, industrial process, industrial manufacturing and educational purposes, including the following. Equipment and computing devices. ---Measuring and testing equipment; ---Control equipment; ---Laboratory equipment; --- Accessory equipment used in conjunction with the above equipment (such as sample processing equipment). Computing devices and components and similar equipment that fall within the scope of Information Technology Equipment (ITE) shall be The electromagnetic compatibility standard for equipment specified in this document may be used in systems within the scope of this document without additional testing. It is generally believed that this series of product standards takes precedence over the corresponding general EMC standards. This document covers the following devices. a) Electrical equipment for measurement and testing. This type of equipment refers to equipment that uses electricity to measure, indicate or record one or more electrical or non-electrical quantities, and also includes non-measuring equipment. equipment such as signal generators, measurement standards, power supplies, and sensors. b) Electrical equipment for control. This type of equipment is a device that controls one or more output quantities to specified values, each of which is set manually, locally or Remotely programmed, or determined by one or more input variables. This type of equipment includes industrial process measurement and control devices, which are The following devices are composed, for example. ---Process controllers and regulators; ---Programmable controller; --- Power supply units for equipment and systems (centralized or dedicated); ---Analog/digital indicators and recorders; ---Process detection instruments; ---Sensors, positioners, intelligent actuators, etc. c) Electrical equipment for laboratory use, including in vitro diagnostic (IVD) medical equipment. This type of equipment is used to prepare or analyze substances, or to measure, indicate, or monitor physical quantities. This type of equipment can also be used to Outside the laboratory. d) Equipment of categories a), b) or c) above that is equipped with radio functional components (e.g. components for wireless communication). The equipment within the scope of this document may operate in different electromagnetic environments; different emission and immunity standards may apply depending on the electromagnetic environment. Degree test requirements. This document considers 3 types of electromagnetic environments. ---Basic electromagnetic environment;
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 18268.1-2025_English be delivered?

Answer: Upon your order, we will start to translate GB/T 18268.1-2025_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 18268.1-2025_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 18268.1-2025_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 18268.1-2025?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 18268.1-2025 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.